Use this procedure to resolve the following problem: Missing
remote adapter (SRC xxxx9076)
- An adapter attached in either an Auxiliary Cache or Dual
Storage IOA configuration was not discovered in the allotted time.
To obtain additional information about the configuration involved,
locate the formatted log in the Product Activity Log.
- Access SST/DST.
- Access the Product Activity Log and record address information.
- If a D IPL was not performed to get to SST/DST:
- The log information is formatted. Access the Product Activity
Log and display the SRC that sent you here. Press the F9 key for "Address
Information". This is the reporting adapter address. Then, press F12
to cancel and return to the previous screen. Then press the F4 key
to view the "Additional Information" to record the formatted log information.
The "Type of adapter connection" field indicates the type of configuration
involved.
- If a D IPL was performed to get to DST:
- The log information is not formatted. Access the Product Activity
Log and display the SRC that sent you here. The direct select address
(DSA) of the adapter is in the format BBBB-Cc-bb:
- BBBB
- hexadecimal offsets 4C and 4D
- Cc
- hexadecimal offset 51
- bb
- hexadecimal offset 4F
In order to interpret the hexadecimal information
to get device addresses. See More information from hexadecimal
reports . The "Type of adapter connection" field
indicates the type of configuration involved.
- Determine which of the following is the cause of your specific
error and take the appropriate actions listed. If this does not correct
the error, contact your hardware service provider. The possible causes
are:
- An attached adapter for the configuration is not installed or
is not powered on. Some adapters are required to be part of a Dual
Storage IOA Configuration. Ensure that both adapters are properly
installed and powered on. Use the Hardware Service Manager to determine
the missing remote adapter that is paired with the reporting adapter.
- If this is an Auxiliary Cache or dual storage IOA configuration,
then both adapters may not be in the same partition. Ensure that both
adapters are assigned to the same partition.
- An attached adapter does not support the desired configuration.
- An attached adapter for the configuration failed. Take action
on the other errors that have occurred at the same time as this error.
- Adapter code levels are not up to date or are not at the same
level of supported function. Ensure that the code for both adapters
is at the latest level.
- A PCIe cable to a PCIe storage enclosure might be failing.
Note: The adapter that is logging this error will run in a performance
degraded mode, without caching, until the problem is resolved.
This