The system is running degraded. Array bit steering may be able to correct this problem without replacing hardware.

  1. Power off the system (see Powering on and powering off the system ).
  2. To determine the action to perform, use the following table.

    System:

    Action:

    8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D, 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8248-L4T, 8268-E1D, 8408-E8D, 9109-RMD, 9119-FHB, 9125-F2C

    Power on the system to the hypervisor standby.
    Note: Slow boot is not supported.

    8233-E8B, 8236-E8C

    Determine the level of firmware the system is running.

    Is system firmware AL710_xxx installed?

    8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD

    Determine the level of firmware the system is running.

    Is system firmware AM710_xxx installed?

    This ends the procedure.

  3. If the problem persists, replace the FRU that is listed after this procedure in the failing item list. See System FRU locations for instructions. This ends the procedure.