Locations — 0588 and 5088 expansion units

Expansion unit part locations.

Note: The known logical location codes for this unit are listed next to the corresponding physical location in the following information. If you are working with a logical location code for this unit and it is not listed in the following information, contact your next level of support.

The following diagram shows field replaceable unit (FRU) layout in the expansion units. Use it with the following tables. If you need address information, refer to Addresses — 0588 and 5088 expansion units.

Figure 1. Expansion units
Expansion units
Figure 2. Expansion units, top view
Expansion units, top view

The following table provides the components available for callout on the expansion units. It matches those components with the FRU containing the component. The other columns give location information, a link to a removal and replacement procedure, and additional information.

Attention: After replacing any part on a server or expansion unit, perform Verifying the repair.
Table 1. FRU locations and failing components
Failing item name Symbolic failing item name Physical location code Link to part number Failing item removal and replacement procedures
Expansion unit backplane
  • SPCN
  • Card enclosure or backplane
  • Multi-adapter bridge (all)

TWRCARD
MA_BRDG
MABRCFG
PPCITWR
PRI_PCI
HSL_LNK
PIOCARD
MASBUST
WRBKPLT
WRPLNR

Un-CB1 28B8 Exchanging the tower card in the 5088 and 0588 expansion units
PCI adapter in slot 1

PIOCARD
MASBUS
SLOTERR

Un-CB1-C01 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 2

PIOCARD
MASBUS
SLOTERR

Un-CB1-C02 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 3

PIOCARD
MASBUS
SLOTERR

Un-CB1-C03 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 4

PIOCARD
MASBUS
SLOTERR

Un-CB1-C04 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 5

PIOCARD
MASBUS
SLOTERR

Un-CB1-C05 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 6

PIOCARD
MASBUS
SLOTERR

Un-CB1-C06 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 7

PIOCARD
MASBUS
SLOTERR

Un-CB1-C07 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 8

PIOCARD
MASBUS
SLOTERR

Un-CB1-C08 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 9

PIOCARD
MASBUS
SLOTERR

Un-CB1-C09 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
RIO/HSL adapter card
  • HSL I/O adapter
  • PCI host bridge adapter

SIIOADP
SIADPCD
SI_PHB

Un-CB1-C10 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 11

PIOCARD
MASBUS
SLOTERR

Un-CB1-C11 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 12

PIOCARD
MASBUS
SLOTERR

Un-CB1-C12 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 13

PIOCARD
MASBUS
SLOTERR

Un-CB1-C13 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 14

PIOCARD
MASBUS
SLOTERR

Un-CB1-C14 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI adapter in slot 15

PIOCARD
MASBUS
SLOTERR

Un-CB1-C15 Part number catalog Exchanging cards (concurrent) in the 5088 and 0588 expansion units
PCI bridge set 1

BRDGSET
BRDGST1

Un-CB1-C01
Un-CB1-C02
Un-CB1-C03
Un-CB1-C04

  Replace the cards using the remove and replace procedures corresponding to the locations indicated.
PCI bridge set 2

BRDGSET
BRDGST2

Un-CB1-C05
Un-CB1-C06
Un-CB1-C07
Un-CB1-C08
Un-CB1-C09

  Replace the cards using the remove and replace procedures corresponding to the locations indicated.
PCI bridge set 3

BRDGSET
BRDGST3

Un-CB1-C11
Un-CB1-C12
Un-CB1-C13
Un-CB1-C14
Un-CB1-C15

  Replace the cards using the remove and replace procedures corresponding to the locations indicated.
Power distribution board   Un-PB1 Part assembly diagrams for 0551, 0588, 5079, 5088, 5294, and 5296 Exchanging the power distribution board in the 5088 and 0588 expansion units
Power supply 1   Un-P01 Part assembly diagrams for 0551, 0588, 5079, 5088, 5294, and 5296 Exchanging the power supplies in the 5088 and 0588 expansion units
Power supply 2   Un-P02 Part assembly diagrams for 0551, 0588, 5079, 5088, 5294, and 5296 Exchanging the power supplies in the 5088 and 0588 expansion units
Fan 1   Un-B01 Part assembly diagrams for 0551, 0588, 5079, 5088, 5294, and 5296 Exchanging the air-moving device (AMD) in the 5088 and 0588 expansion units
Fan 2   Un-B02 Part assembly diagrams for 0551, 0588, 5079, 5088, 5294, and 5296 Exchanging the air-moving device (AMD) in the 5088 and 0588 expansion units
Fan controller card AMDCTRL Un-BB1 Part assembly diagrams for 0551, 0588, 5079, 5088, 5294, and 5296 Exchanging the AMD controller card in the 5088 and 0588 expansion units
Display panel   Un-NB1 Part number catalog Exchanging the control panel in the 5088 and 0588 expansion units
RIO/HSL adapter card connector

HSL_LNK
HSL2
HSL2_xx
HSLH
HSLH_xx

Un-CB1-C10-00 Part number catalog Exchanging RIO/HSL cables
RIO/HSL adapter card connector

HSL_LNK
HSL2
HSL2_xx
HSLH
HSLH_xx

Un-CB1-C10-01 Part number catalog Exchanging RIO/HSL cables
Notes:
  1. Card positions C01, C05, and C11 are required to be either I/O processors or Integrated xSeries® servers (IXS).
  2. J11 is an RPO connection, J14 is a uninterruptible power supply connector, J15 is an SPCN 1 connector, and J16 is an SPCN 2 connector.
  3. Multi-adapter bridge domains are labeled PCI Bridge Set inside the I/O unit.
  4. The following table provides information necessary to identify the IOP to which IOAs are assigned.
    • The left column indicates the domain in which IOA assignment is allowed.
    • The right column is used to determine the IOP to which an IOA is assigned.
    • The first position in the list must be an IOP. The remaining positions may be IOPs or IOAs. IOAs are assigned to the first IOP located to their left in the list. Although IOAs can be manually reassigned using SST/DST, the IOA assignments return to the default order after each IPL.
      Table 2. Identify the IOP to which IOAs are assigned
      Multi-adapter bridge domain / PCI bridge set IOA assignment rules
      C01 - C04 C01, C02, C03, C04
      C05 - C09 C05, C06, C07, C08, C09
      C11 - C15 C11, C12, C13, C14, C15

Send feedback | Rate this page