ANYPROC

The failing component is one of the system processors.

Use the table below to determine what FRU to replace and how to replace it.

Note: To simplify this information, secondary units on the 570 server are numbered 1 through 3-secondary unit 1 being nearest to the primary unit and secondary unit 3 being furthest.
Model 5705/70 with secondary units
Table 1. ANYPROC failing components
System model Name of symbolic FRU to locate FRU name (replace in order, one at a time) Link to locations information
505 ANYPROC System backplane Locations — model 505
510 and OpenPower® 710 ANYPROC System backplane Locations — model 510 and OpenPower 710
515, 520, and 525 ANYPROC System backplane Locations — Model 515, 520, and 525
550 and OpenPower 720 ANYPROC Processor card 1 Processor card 2 Locations — OpenPower 720 and Model 550
570 ANYPROC For each unit, starting with the primary unit and then the secondary units:Processor card 1Processor card 2 Locations — Model 570
575 ANYPROC Processor backplane Locations — model 575
590 and 595 ANYPROC For each node, starting with node 0:MCM 0MCM 1 Locations — model 590 and 595

This ends the procedure.


Send feedback | Rate this page