subscribe iconSubscribe to this information
POWER5 information

Locate a failing part in an AIX system or logical partition

You might need to use AIX® tools, before activating the indicator light, to locate a part that is failing. Use the procedure in this section to accomplish this task.

  1. Log in as root user or celogin-.
  2. At the command line, type diag and press Enter.
  3. From the Function Selection menu, select Task Selection and press Enter.
  4. Select Display Previous Diagnostic Results and press Enter.
  5. From the Display Previous Diagnostic Results display, select Display Diagnostic Log Summary. A Display Diagnostic Log display appears. This display contains a chronological list of events.
  6. Look in the T column for the most recent S entry. Select this row in the table and press Enter.
  7. Choose Commit. The details of this log entry are shown.
  8. Record the location information and the SRN value shown near the end of the entry.
  9. Exit to the command line.

Use the location information for the failing part to activate the indicator light that identifies the failing part. For instructions, see Activate the indicator light for the failing part.


Send feedback | Rate this page

Last updated: Fri, Oct 30, 2009