The Linux® operating system detected a failure in the emulex driver.
The first five characters (BFxxx) of these SRCs indicate the driver or subsystem responsible for the error, and the last three characters specifies the error condition. The last three characters of the SRCs are arranged such that 1xx is lowest severity and Fxx is highest severity. For example:
Use the following table to locate the last four characters of the (BF67) Linux SRC that you want to find, then perform the suggested actions.
Table 1. (BF67) Linux reference codes
| Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
|---|---|---|
| 7800 | An ELS IOCB command was posted to a ring and did not complete within
ULP timeout seconds.
If no ELS command is going through the adapter, reboot the system. |
NEXTLVL |
| 7801 | The driver attempted to issue READ_SPARAM mailbox command to the HBA
but there were no buffer available. This message indicates one of the following
conditions:
|
NEXTLVL |
| 7802 | The driver attempted to issue REG_LOGIN mailbox command to the HBA
but there were no buffer available. This message indicates one of the following
conditions:
|
NEXTLVL |
| 7803 | This message indicates one of the following conditions:
This error might indicate a software driver, firmware or hardware problem. |
NEXTLVL |
| 7804 | The Rctl/Type of a received frame did not match any for the configured
masks for the specified ring.
This error might indicate a software driver or firmware problem. |
NEXTLVL |
| 7805 | Received an unknown IOCB command completion.
This error might indicate a software driver or firmware problem. |
NEXTLVL |
| 7806 | The driver wan unable to find a matching command for the completion
received on the specified ring.
This error might indicate a software driver or firmware problem. |
NEXTLVL |
| 7807 | A unknown mailbox command completed.
This error might indicate a software driver, firmware or hardware problem. |
NEXTLVL |
| 7808 | The configuration parameter for scan-down is out of range.
Software driver error. |
NEXTLVL |
| 7809 | The driver attempted to register the HBA interrupt service routine
with the host operating system but failed.
This error might indicate a hardware or driver problem. |
NEXTLVL |
| 780A | The driver manages its own memory for internal usage. This error indicates
a problem occurred in the driver memory management routines. This error might
also indicate the host system in low on memory resources.
This error might indicate a driver or host operating system problem. |
NEXTLVL |
| 780B | This message indicates one of the following conditions:
This error might indicate a software driver problem. |
NEXTLVL |
| 7A00 | The driver decided to drop an ELS Response ring entry.
This error might indicate a software driver or firmware problem. |
NEXTLVL |
| 7A01 | Received a mailbox completion interrupt and there are no outstanding
mailbox commands.
This error might indicate a hardware or firmware problem. Update firmware. |
NEXTLVL |
| 7A02 | The driver issued a CONFIG_LINK mbox command to the HBA that failed.
This error might indicate a firmware or hardware problem. Update firmware or replace adapter. |
NEXTLVL |
| 7A03 | The driver issued a READ_SPARAM mbox command to the HBA that failed.
This error might indicate a firmware or hardware problem. |
NEXTLVL |
| 7A04 | The driver issued a CLEAR_LA mbox command to the HBA that failed.
This error might indicate a firmware or hardware problem. |
NEXTLVL |
| 7A05 | A read nvparams mailbox command failed during config port.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A06 | The driver cannot find the specified buffer in its mapping table.
This error might indicate a software driver or firmware problem. |
NEXTLVL |
| 7A07 | The adapter failed during power-up diagnostics after it was reset.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A08 | The adapter failed during power-up diagnostics after it was reset.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A09 | Adapter initialization failed when issuing READ_REV mailbox command.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A0A | Outdated firmware was detected during initialization.
This error might indicate a hardware or firmware problem. Update firmware. |
NEXTLVL |
| 7A0B | Adapter initialization failed when issuing DUMP_VPD mailbox command.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A0C | Adapter initialization failed when issuing CONFIG_PORT mailbox command.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A0D | Adapter initialization failed when issuing CFG_RING mailbox command.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A0E | Adapter initialization failed when issuing CONFIG_LINK mailbox command.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A0F | Adapter initialization failed when issuing READ_SPARM mailbox command.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A10 | Adapter initialization failed when issuing READ_CONFIG mailbox command.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A11 | Adapter initialization failed when issuing INIT_LINK mailbox command.
This error might indicate a hardware or firmware problem. |
NEXTLVL |
| 7A12 | The driver received an interrupt indicting a possible hardware problem.
This error might indicate a hardware or firmware problem. |
NEXTLVL |