subscribe iconSubscribe to this information
POWER7 information

MAP 4044

Use this MAP to resolve an incorrect or incomplete multipath connection problem.

Use this MAP to resolve the following problems:

The possible causes are:

Considerations:

Attention: Obtain assistance from your Hardware Service Support organization before you replace RAID adapters when SAS fabric problems exist. Because the adapter might contain nonvolatile write cache data and configuration data for the attached disk arrays, additional problems can be created by replacing an adapter when SAS fabric problems exist. Appropriate service procedures must be followed when replacing the cache RAID - dual IOA enablement card (for example, FC5662) because removal of this card can cause data loss if incorrectly performed and can also result in a nondual storage IOA (non-HA) mode of operation.

Step 4044-1

Was the SRN nnnn-4030?

No
Go to Step 4044-4.
Yes
Go to Step 4044-2.

Step 4044-2

Review the device enclosure cabling and correct the cabling as required. To see example device configurations with SAS cabling, see "Serial attached SCSI cable planning.

Step 4044-3

Run diagnostics in system verification mode on the adapter to rediscover the devices and connections.

  1. Start Diagnostics and select Task Selection on the Function Selection display.
  2. Select Run Diagnostics.
  3. Select the adapter resource.
  4. Select System Verification.
Examine the error log. See Examining the hardware error log. Did the error occur again?
No
Go to Step 4044-9.
Yes
Contact your hardware service provider.

Step 4044-4

The SRN is nnnn-4040.

Determine if a problem still exists for the adapter that logged this error by examining the SAS connections as follows:

  1. Start the IBM® SAS Disk Array Manager.
    1. Start Diagnostics and select Task Selection on the Function Selection display.
    2. Select RAID Array Manager.
    3. Select IBM SAS Disk Array Manager.
  2. Select Diagnostics and Recovery Options.
  3. Select Show SAS Controller Physical Resources.
  4. Select Show Fabric Path Graphical View.
Do all expected devices appear in the list and are all paths marked as Operational?
No
Go to Step 4044-5.
Yes
Go to Step 4044-9.

Step 4044-5

Run diagnostics in System Verification mode on the adapter to rediscover the devices and connections.

  1. Start Diagnostics and select Task Selection on the Function Selection display.
  2. Select Run Diagnostics.
  3. Select the adapter resource.
  4. Select System Verification.
Note: At this point, ignore any problems found and continue with the next step.

Step 4044-6

Determine if the problem still exists for the adapter that logged this error by examining the SAS connections as follows:

  1. Start the IBM SAS Disk Array Manager.
    1. Start Diagnostics and select Task Selection on the Function Selection display.
    2. Select RAID Array Manager.
    3. Select IBM SAS Disk Array Manager.
  2. Select Diagnostics and Recovery Options.
  3. Select Show SAS Controller Physical Resources.
  4. Select Show Fabric Path Graphical View.
  5. Select a device with a path that is not Operational (if one exists) to obtain additional details about the full path from the adapter port to the device. See Viewing SAS fabric path information for an example of how this additional detail can be used to help isolate where in the path the problem exists.

Do all expected devices appear in the list and are all paths marked as Operational?

No
Go to Step 4044-7.
Yes
Go to Step 4044-9.

Step 4044-7

Go to SAS fabric identification. Then continue with the next step.

Step 4044-8

Determine if the problem still exists for the adapter that logged this error by examining the SAS connections as follows:

  1. Start the IBM SAS Disk Array Manager.
    1. Start Diagnostics and select Task Selection on the Function Selection display.
    2. Select RAID Array Manager.
    3. Select IBM SAS Disk Array Manager.
  2. Select Diagnostics and Recovery Options.
  3. Select Show SAS Controller Physical Resources.
  4. Select Show Fabric Path Graphical View.
  5. Select a device with a path that is not Operational (if one exists) to obtain additional details about the full path from the adapter port to the device. See Viewing SAS fabric path information for an example of how this additional detail can be used to help isolate where in the path the problem exists.

Do all expected devices appear in the list and are all paths marked as Operational?

No
Go to Step 4044-7.
Yes
Go to Step 4044-9.

Step 4044-9

When the problem is resolved, see the removal and replacement procedures topic for the system unit on which you are working and do the "Verifying the repair" procedure.



Send feedback Rate this page

Last updated: Thu, July 23, 2015