POWER7 information

Hardware Management Console parts

Contains illustrations, part descriptions and part numbers that are used when ordering replacement parts for your Hardware Management Console (HMC).

Personal computer parts

Contains part number information for parts used in assembling your HMC.

Note: FRU parts and part numbers are subject to update due to our parts system substitution-update policy. With our parts system substitution-update policy we make every effort to supply you with the latest components available for your model HMC.

The following table contains a cross-reference equivalent of the HMC machine type and model number to the personal computer machine type and model number. For personal computer parts information not listed in the following tables, see hardware maintenance manual for your personal computer.

Table 1. Equivalent maintenance information for the HMC's personal computer hardware
HMC machine type and model number (available on the serial number plate of your HMC) Equivalent PC server machine type and model number Hardware maintenance manuals (HMM)
7310-CR4, 7042-CR4 7978 Model 42U or 7978 Model PBT See Problem determination and service guide
7042-CR5 7946 Model 52U or 7946 Model PAL See Problem determination and service guide
7042-CR6 7944 Model PCH See Problem determination and service guide
7042-CR7 7914 Model PCH See Problem determination and service guide
7310-C06 and 7042-C06 4362 Model 52U or 4362 Model PAT See Problem determination and service guide
7042-C07 4367 Model 32U, 4367 Model PAM or 4367 Model PAR See Problem determination and service guide
7042-C08 7946 Model 52U See Problem determination and service guide
For the latest information regarding maintenance of your HMC PC, system board specifications, and parts, see PC hardware maintenance manuals. To obtain the latest versions of these publications through the IBM® website, follow this procedure:
  1. Go to the IBMLink outside Information Center website at http://www.ibm.com.
  2. Select Support & downloads.
  3. Go to Select product or service type for support and expand the Choose support type box.
  4. Select System x from the menu listing, and then select the Go icon.
  5. On the right side of the menu, locate the Quick path box, and type the PC model that corresponds to your HMC, and then select Go.
  6. Select the Troubleshooting tab, located on the support menu.
  7. In the Available topics box, select Service/Support guide. Then click the Go icon.
  8. Click the link that appears under Service/Support guide.
  9. Click the file link number listed under File link. The file for the hardware maintenance manual will open.

7310-CR4, 7042-CR4, and 7042-CR5 parts

Models 7310-CR4 and 7042-CR4 use a personal computer machine type of 7978 Model 42U, and Model 7042-CR5 use a personal computer machine type of 7946 Model 52U for its base configuration. To access the personal computer hardware maintenance manuals, see Personal computer parts.

Note: Each PC hardware maintenance manual may reference more than one machine type in its title. If necessary, to cross-reference to the original PC hardware maintenance manual, make sure that you find the hardware maintenance manual for the PC machine type and model for the HMC that you are servicing.
The following illustration and table identifies the major components that make up the Models 7310-CR4 and 7042-CR4.
Figure 1. Models 7310-CR4 and 7042-CR4 parts illustration
7310-CR4 and7042-CR4 Parts Illustration
Notes:
  1. Field replaceable units (FRUs) must be serviced only by an authorized service provider.
  2. Customer replaceable units (CRUs) can be replaced by the customer. The CRUs are defined as either Tier 1 or Tier 2 as follows:
    Tier 1 CRU
    Procedure that a customer can perform without input from a service provider. The procedure used to service this type of component is usually required to be done by the customer.
    Tier 2 CRU
    Procedure that a customer can perform, but may require support from a service provider. The procedure used to service this component is usually not required to be done by the customer.
  3. If the part you are replacing is not identified as being either Tier 1 or Tier 2, call your service provider to service the FRU.
Table 2. 7310-CR4 and 7042-CR4 Parts listing
Index Description Tier 1 CRUs Tier 2 CRUs Part number
1 Top cover assembly *   43W0609
2 Heat sink assembly     39Y9423
3 Air baffles *   39Y9420
4 Memory, 512 MB ECC DRR *   39M5781
5 Not applicable to this model      
6 PCI-X riser card   * 39Y6975
7 Not applicable to this model      
8 Planar, SATA     60Y0861
8 Planar, SATA     60Y0865
9 Power supply, 670 W *   39Y7189
10 Power supply filler panel *   XXXXXXX
11 Chassis assembly     39Y9522
12 Fan assembly unit (dual fans) *   26K8083
13 DVD-RAM Drive *   42C0955
14 Operator information panel card assembly     39K6973
15 Not applicable to this model      
16 Not applicable to this model      
17 Not applicable to this model      
18 Not applicable to this model      
19 Power backplane   * 39Y6972
Table 3. 7310-CR4 and 7042-CR4 Parts listing (continued)
Index Description Units   Part number
20 Not applicable to this model      
21 Simple-swap filler panel, 3.5 inch *   23K4990
22 Not applicable to this model      
23 Disk drive, 80 GB SATA *   39M4503
23 Disk drive, 250 GB SATA *   39M4511
24 Simple-swap SATA disk drive cage   * 32R2823
25 Not applicable for this model      
26 Power cable, SATA, with backplate *   26K8060
  Microprocessor, 2.0 GHz with heat sink (Used on 60Y0861 Planar)     42C4229
  Microprocessor, 2.5 GHz 4 core (Used on 60Y0865 Planar)     44R5646
  Media bezel assembly *   39Y9419
  Rack latch assembly, EIA   * 26K8080
  Service label, 3.5 inch, SATA *   32R2820
  Service label, right fan door *   39Y9418
  USB connector cable, front panel (field replaceable unit)   * 26K8058
  CD-RW/DVD drive interposer card   * 42C3983
  Slides and hardware   * 52P8517
  Battery, system board, 3.0 V *   33F8354
  Mouse, (Black) *   03N6669
  Modem cable (see HMC modem cable part numbers)      
The following illustration and table identifies the major components that make up the Model 7042-CR5.
Figure 2. Models 7042-CR5 parts illustration
7042-CR5 Parts Illustration
Table 4. 7042-CR5 Parts listing
Index Description Tier 1 CRUs Tier 2 CRUs FRU Part number
1 Top cover (All models) 43V6933    
2 DIMM air duct 43V7050    
3 PCI-X riser card assembly   43V7068  
4 PCI Express riser card, x16, assembly   43V7066  
5 Memory, 1 GB PC3-10600R-999 DDR3 ECC 44T1490    
5 Memory, 2 GB PC3-10600R-999 DDR3 ECC 44T1491    
5 Memory, 2 GB PC3-10600R-999 DDR3 ECC 44T1492    
5 Memory, 4 GB PC3-10600R-999 DDR3 ECC 44T1493    
5 Memory, 8 GB PC3-10600R-999 DDR3 ECC 46C7453    
6 Virtual media key 46C7528    
7 Power supply bay filler 49Y4821    
8 Power supply, 675 Watt 39Y7201    
9 Chassis assembly (without front bezel)     49Y4813
10 CD-RW/DVD drive 44W3255    
10 CD-RW/DVD-RW drive 44W3256    
11 Rack latch kit   49Y4815  
12 Bezel   49Y4818  
13 Operator information panel assembly   44E4372  
14 Blank filler 49Y4821    
15 Hard disk drive, 2.5-inch 50 GB simple-swap solid state   43W7733  
16 Filler, hot-swap hard disk drive 44T2248    
17 Hard disk drive, 2.5-inch, hot-swap 300 GB 10K 00E6167    
19 Backplane, SAS hard disk drive   43V7071  
20 Fan, hot-swap 40 mm 43V6929    
21 System board     43V7072
22 ServeRAID-MR10i adapter   43W4297  
23 ServeRAID-BR10i adapter 44E8690    
24 SAS/SATA riser card 43V7067    
25 Retention module, heat sink     49Y4822
26 Microprocessor, 1.86 GHz, 80W, (model 12x)     46D1272
26 Microprocessor, 2.00 GHz, 80W, (model 22x)     46D1271
26 Microprocessor, 2.13 GHz, 60W     46D1268
26 Microprocessor, 2.13 GHz, 80W, (model 3Ax)     46D1270
26 Microprocessor, 2.26 GHz, 60W, (models 42x and 4Lx)     46D1269
Table 5. 7042-CR5 Parts listing (continued)
Index Description Units   Part number
26 Microprocessor, 2.26 GHz, 80W, (model 32x)     46D1267
26 Microprocessor, 2.40 GHz, 60W     49Y6807
26 Microprocessor, 2.40 GHz, 80W, (models 52x and 54x)     46D1266
26 Microprocessor, 2.53 GHz, 80W, (models 62x and 64x)     46D1265
26 Microprocessor, 2.66 GHz, 95W, (models 74x and 76x)     46D1264
26 Microprocessor, 2.80 GHz, 95W, (model E3Y)     46D1263
26 Microprocessor, 2.93 GHz, 95W, (models 92x, 94x, and 96x)     46D1262
27 Heat sink assembly     49Y4820
28 Air baffle kit (Microprocessor air baffle, clamp, and DIMM air duct) (all models) 43V6931    
  Cable management arm 49Y4817    
  Cable, hard disk drive configuration   43V7023  
  Cable, operator panel   46c4139  
  Cable, SAS power   46C4148  
  Cable, SAS signal, 120 mm   43V7019  
  Cable, SAS signal, 200 mm   43V6922  
  Cable, SAS signal, 300 mm   49Y4850  
  Cable, SATA DVD 43V6914    
  Cable, USB/video   43V6920  
  Cable assembly, simple-swap   43V7042  
  Cable, line cord, 2.8 m 39M5377    
  Cover, safety 240VA     49Y4823
  DVD drive bay filler 49Y4868    
  EMC filler 44T2248    
  Ethernet card 43V7073    
  Labels, chassis 49Y4812    
  Labels, system service 46C6799    
  Low-profile adapter varies    
  Miscellaneous parts kit   49Y4814  
  Riser-card bracket: full-height, half-length 43V6936    
  Riser-card bracket: low-profile 43V6939    
  Bracket assembly, rear I/O 43V6938    
  SAS adapter retainer 49Y4852    
  ServeRAID-M5010 adapter   46M0851  
  ServeRAID-MR10i battery carrier kit   44E8763  
  ServeRAID-MR10M battery carrier kit   44E8844  
  Video adapter, NVIDIA FX 1700 43V5765    
  Video adapter, NVIDIA FX 570 43V5782    

7042-CR6 parts

Machine type 7042-CR6 uses a personal computer machine type of 7944-PCH for its base configuration. To access the personal computer hardware maintenance manuals, see Personal computer parts.

Note: Each PC hardware maintenance manual might reference more than one machine type in its title. If necessary, to cross-reference to the original PC hardware maintenance manual, make sure that you find the hardware maintenance manual for the PC machine type and model for the HMC that you are servicing.

The following illustration and table identifies the major components that make up model 7042-CR6.

Figure 3. Model 7042-CR6 parts
7042-CR6 parts
Notes:
  1. Field replaceable units (FRUs) must be serviced only by an authorized service provider.
  2. Customer replaceable units (CRUs) can be replaced by the customer. Definitions of tier 1 and tier 2 CRUs for this model HMC follow:
    Tier 1 CRU
    A procedure that a customer can perform without input from a service provider. The procedure used to service this type of component is usually required to be done by the customer.
    Tier 2 CRU
    A procedure that a customer can perform, but might require support from a service provider. The procedure used to service this component is not usually required to be done by the customer.
  3. If the part you are replacing is not identified as being either tier 1 or tier 2, call your service provider to service the FRU.
Table 6. 7042-CR6 parts listing
Index Description Tier 1 CRU Tier 2 CRU Part number
1 Top cover 59Y3927    
2 Filler, PCI 59Y3969    
3 PCI-X riser card assembly   43V7068  
4 PCI Express riser card, x16, assembly   43V7066  
5 Memory, 2 GB single-rank DDR3-1333 RDIMM 49Y1444    
6 Virtual media key 46C7528    
7 Power supply bay filler (models A2x, B2x, C2x, D2x, G2x, H2x, J2x, M2x, and N2x) 49Y4821    
8 Power supply, 675 Watt, ac 39Y7201    
9 Chassis assembly (without front bezel)     59Y3931
10 DVD-RW drive 44W3256    
11 Rack latch kit   49Y4815  
12 Bezel, 8 hard disk bays   59Y3916  
12 Bezel, 4 hard disk and 1 optical drive bays   59Y3917  
13 Operator information panel assembly   44E4372  
14 Filler, hard disk drive bay 59Y3925    
15 Not applicable to this model      
16 Filler, EMC 44T2248    
17 Hard disk drive, 2.5-inch hot-swap, 500 GB, 10 K 42D0753    
18 Backplate assembly, simple-swap   59Y3919  
19 Backplane, SAS   59Y3915  
20 Fan 43V6929    
21 System board     59Y3793
22 ServeRAID-M1015 adapter (models B2x, C2x, D2x, H2x, and N2x) 46M0861    
23 ServeRAID-BR10il v2 adapter (model A2x) 49Y4737    
24 SAS/SATA riser card 43V7067    
25 Retention module, heat sink     49Y4822
26 Microprocessor, 2.53 GHz 80W (model F2x)     49Y7052
27 Heat sink assembly (models A2x, B2x, C2x, D2x, F2x, G2x, H2x, J2x, and M2x)     49Y4820
28 Air baffle kit (Microprocessor air baffle, clamp, and DIMM air duct) (all models) 59Y3914    
29 DIMM air duct 43V7050    

The 7042-CR6 parts that are listed in the following table are not illustrated.

Table 7. 7042-CR6 parts listing (continued)
Description Tier 1 CRU Tier 2 CRU Part number
Cable, hard disk drive configuration   59Y3918  
Cable, operator panel   46C4139  
Cable, SAS power   59Y3920  
Cable, SAS signal, 300 mm   49Y4850  
Cable, SATA DVD   59Y3922  
Cable, USB/video   59Y3923  
Cable, line cord (models A2x, B2x, C2x, D2x, F2x, G2x, H2x, J2x, M2x, and N2x) 39M5377    
Cage, hard disk drive   59Y3968  
Cage, optical drive   59Y3924  
Safety cover     49Y4823
Filler, DVD drive bay 49Y4868    
2-port 1 Gb Ethernet card 69Y4509    
2-port 1 Gb Ethernet card, mechanical kit 69Y4586    
Labels, chassis 59Y3998    
Labels, system service 59Y3926    
Miscellaneous parts kit   69Y4506  
Riser-card bracket: full-height, half-length   43V6936  
Riser-card bracket: low-profile (models J2x and M2x)   43V6939  
Bracket assembly, rear I/O     43V6938
SAS adapter retainer   49Y4852  
Slide rail kit   59Y3792  
CMA kit 49Y4817    
Slide rail kit, Gen-II   69Y4391  
CMA kit, Gen-II 69Y4392    
Screw kit 59Y4922    
Thermal grease kit   41Y9292  
Hypervisor, embedded USB flash device 42D0545    
Alcohol wipes   59P4739  

For a more complete listing of power cords for the HMC, see Planning for power.

7042-CR7

Machine type 7042-CR7 uses a personal computer machine type of 7914-PCH for its base configuration. To access the personal computer hardware maintenance manuals, see Personal computer parts.

Note: Each PC hardware maintenance manual might reference more than one machine type in its title. If necessary, to cross-reference to the original PC hardware maintenance manual, ensure that you find the hardware maintenance manual for the PC machine type and model for the HMC that you are servicing.

The following illustration and table identifies the major components that make up model 7042-CR7.

Figure 4. Model 7042-CR7 parts
7042-CR7 parts
Notes:
  1. Field replaceable units (FRUs) must be serviced only by an authorized service provider.
  2. Customer replaceable units (CRUs) can be replaced by the customer. Definitions of tier 1 and tier 2 CRUs for this model HMC follow:
    Tier 1 CRU
    A procedure that a customer can perform without input from a service provider. The procedure used to service this type of component is usually required to be done by the customer.
    Tier 2 CRU
    A procedure that a customer can perform, but might require support from a service provider. The procedure used to service this component is not usually required to be done by the customer.
  3. If the part you are replacing is not identified as being either tier 1 or tier 2, call your service provider to service the FRU.
Index Description CRU part number (Tier 1) CRU part number (Tier 2) Part number
1 Top cover   94Y7569
2 Air baffle     94Y7568
3 PCI bracket 2 94Y7566  
3 PCI-X riser card 94Y7590  
4 PCI Express riser card, Gen3 x16 94Y7588  
5 Filler, PCI     94Y7608
6 Memory, 8 GB dual-rank 1.35 V, DDR3, 1333 MHz, RDIMM 49Y1415  
7 Power supply bay filler     94Y7610
8 Power supply, 550 W, ac 43X3312  
9 Chassis assembly, 2.5-inch hard disk drive (HDD) (without front bezel)     94Y7573
10 DVD-RW drive 44W3256  
11 Operator information panel assembly 90Y5821  
11 Operator information panel assembly, advanced 90Y5822  
  USB assembly, front 94Y7621    
  USB assembly, front dual-port 00D3338    
12 Not applicable to this model    
13 Not applicable to this model    
14 Not applicable to this model    
15 HDD, 2.5-inch hot-swap, 500 GB, 7.2 K 81Y9727  
16 EIA bracket     94Y7570
17 Not applicable to this model      
18 Backplane, 2.5-inch hot-swap HDD 94Y7587  
19 Fan module, hot-swap 94Y7564  
20 System board 00Y8375  
21 ServeRAID M5110 SAS/SATA adapter 81Y4482  
21 ServeRAID M5100 series 512 MB flash (RAID 5 upgrade) 81Y4488  
21 ServeRAID M5110 series battery Kit 81Y4491  
22 Retention module, heat sink 94Y7739  
23 Microprocessor installation tool 94Y9955  
23 Microprocessor, Intel Xeon E5-2640, 2.50 GHz, 15 MB, 1333 MHz, 95 W (6-core) 81Y5166  
24 Heat sink assembly, 95 W 94Y7602  

The 7042-CR7 parts that are listed in the following table are not illustrated.

Description CRU part number (Tier 1) CRU part number (Tier 2) Part number
Battery, 3.0 V 33F8354    
Battery, ServeRAID 81Y4579    
Cable, power cord 39M5377    
Cable, mini SAS 1 meter (3.3 feet) 39R6530    
Cable, USB 81Y6659  
Cable, USB conversion 39M2909  
Cable, serial conversion 46M4027  
Cable, virtual media Gen 2 46M4028  
Cable, power, 2.5-inch HDD 81Y6663  
Cable, backplane, 2.5-inch hot-swap HDD 81Y6667  
Cable, operator information panel 81Y6669  
Cable, SATA DVD 81Y6671  
Cable, video 81Y6673  
Cable, adapter power 81Y6676  
Cable, ServeRAID battery 90Y7309  
Cable, ServeRAID power module 90Y7310  
Cable, SPECpower 00D3334  
Panel, light path diagnostics 00D3863  
Labels, chassis 94Y7604  
Labels, system service 94Y7605  
Bezel, 2.5-inch hard disk bays, and 1 optical drive bay 94Y7606  
Thermal grease kit 41Y9292  
Alcohol wipes 59P4739  
Miscellaneous parts kit     94Y7571
Filler, EMC     44T2248
Filler, DVD drive bay     49Y4868
Filler, HDD bay     59Y3925
Filler, fan     94Y7572
Remote RAID battery tray     94Y7609
CMA kit     49Y4817
Slide rail kit, Gen-III     94Y6625
CMA kit, Gen-III     94Y6626
Slide rail kit, universal     94Y6719

For a complete listing of power cords for the HMC, see Planning for power.

7310-C06 and 7042-C06 parts

Machine types 7310-C06 and 7042-C06 use a personal computer machine type of 4362-52U for its base configuration. To access the personal computer hardware maintenance manuals, see Personal computer parts.

Note: Each PC hardware maintenance manual may reference more than one machine type in its title. If necessary, to cross-reference to the original PC hardware maintenance manual, make sure that you find the hardware maintenance manual for the PC machine type and model for the HMC that you are servicing.

The following illustration and table identifies the major components that make up the Models 7310-C06 and 7042-C06.

Figure 5. Models 7310-C06 and 7042-C06 parts illustration
7310-C06 and 7042-C06 Parts Illustration
Notes:
  1. Field replaceable units (FRUs) must be serviced only by an authorized service provider.
  2. Customer replaceable units (CRUs) can be replaced by the customer. A definition of Tier 1 and Tier 2 CRUs for this model HMC is:
    Tier 1 CRU
    Uses a procedure that a customer can perform without input from a service provider. The procedure used to service this type of component is usually required to be done by the customer.
    Tier 2 CRU
    Uses a procedure that a customer can perform, but may require support from a service provider. The procedure used to service this component is usually not required to be done by the customer.
  3. If the part you are replacing is not identified as being either Tier 1 or Tier 2, call your service provider to service the FRU.
Table 8. 7310-C06 and 7042-C06 parts listing
Index Description Tier 1 CRU Tier 2 CRU Part number
1 Chassis assembly, non-redundant power supply     42C8916
2 Front-panel assembly   * 25R8865
3 Front USB connector assembly (cable)   * 26K7340
4 DVD-RAM drive *   43W4577
5 Diskette drive *   33P3343
6 Diskette drive bezel *   25R8857
7 Bezel, upper *   42C8912
8 Bezel, lower *   42C8913
9 Hard disk drive, SATA, 80 GB simple swap *   39M3701
  Disk drive tray *   25R8864
  Half -Height disk drive, slim bare Rambo-5 *   42C0957
10 Retention bracket, PCI   * 13N2993
11 Hard disk drive cage, 3.5-inch *   42C8910
12 Disk drive backplane (for 3.5 inch simple-swap SATA disk drives)   * 25R8842
13 3.5 inch disk drive air-duct assembly   * 39Y9860
14 System board assembly     43W4982
15 SAS/SATA controller   * 42C1279
16 Microprocessor, 2.13 GHz     41Y3849
17 Fan-sync     43W0401
18 Side cover with lock *   25R8859
19 Power supply, 400 watt     39Y7297
20 Memory, 512MB *   41Y2725
21 System fan, rear   * 25R8829
  PSU adapter bracket (not shown)   * 42C7509

7310-C06 parts listed in the following table are not illustrated.

Table 9. 7310-C06 and 7042-C06 parts listing (continued)
Description Tier 1 CRU Tier 2 CRU Part number
3.0 V battery   * 33F8354
Bezel kit *   13N2450
Cable, 24-inch SATA signal   * 25R5635
Cable, 400 watt DAS   * 25R8849
Shield kit *   13N2997
Service label     43W0417
Cable, panel mount   * 13N2413
Cable, diskette drive   * 39R8112
Cable, IDE signal   * 13N2466
Cable, serial port 2 *   42C1053
EMC I/O shield *   43W4986
EMC shield kit *   13N2997
Mouse, 2-button *   03N6669
Kit, shield *   13N2997
Kit, bezel *   13N2450
Retainer kit (for optical and diskette drives) *   39R9369
Retention module, fan sync     25R8873
Stabilizing feet *   13N2985
C2 switch   * 39Y9783
Miscellaneous Kit (clip, insulator, retainer) *   39Y9773
Modem cable (see HMC modem cable part numbers)      

7042-C07 parts

Machine type 7042-C07 uses a personal computer machine type of 4367-32U for its base configuration. To access the personal computer hardware maintenance manuals, see Personal computer parts.

Note: Each PC hardware maintenance manual may reference more than one machine type in its title. If necessary, to cross-reference to the original PC hardware maintenance manual, make sure that you find the hardware maintenance manual for the PC machine type and model for the HMC that you are servicing.

The following illustration and table identifies the major components that make up the Model 7042-C07.

Figure 6. Model 7042-C07 parts illustration
7042-C07 Parts Illustration
Notes:
  1. Field replaceable units (FRUs) must be serviced only by an authorized service provider.
  2. Customer replaceable units (CRUs) can be replaced by the customer. A definition of Tier 1 and Tier 2 CRUs for this model HMC is:
    Tier 1 CRU
    Uses a procedure that a customer can perform without input from a service provider. The procedure used to service this type of component is usually required to be done by the customer.
    Tier 2 CRU
    Uses a procedure that a customer can perform, but may require support from a service provider. The procedure used to service this component is usually not required to be done by the customer.
  3. If the part you are replacing is not identified as being either Tier 1 or Tier 2, call your service provider to service the FRU.
Table 10. 7042-C07 parts listing.

7042-C07 parts listing

Index Description Tier 1 CRU Tier 2 CRU Part number
1 Chassis assembly, non-redundant power supply, (without diskette drive)     44X0386
2 Control panel assembly   * 44E7571
3 Dual USB connector assembly (cable)   * 26K7340
4 Half Height DVD-RAM drive *   43W8467
5 Diskette drive (Shown in drawing but not available on the 7042-C07) *   N/A
6 Diskette drive bezel (Shown in drawing but not available on the 7042-C07) *   N/A
7 Bezel assembly, upper front *   42C7290
8 Bezel assembly, lower front *   42C7293
9 Hard disk drive, 250 GB SATA, simple swap with tray *   39M4511
  Simple Swap disk drive tray *   25R8864
10 Retention bracket, PCI, (front)   * 13N2993
  EMI shield bracket assembly     44E7337
11 Hard disk drive cage, 3.5-inch *   42C8910
Hard disk drive shield for HDD cage     44X0388
12 Disk drive backplane (for 3.5 inch simple-swap SATA disk drives)   * 25R8842
EULER 2.5 Hard disk drive backplane (SATA simple swap)     25R8842
Hard disk drive carrier assembly *   42C7495
13 3.5 inch disk drive air-duct assembly   * 39Y9860
14 System board assembly     43W7312
15 SAS/SATA controller   * 43V7415
16 Microprocessor, 3.0 GHz dual core, 1333 MHz     44E7588
17 Fan-sink (heatsink)     43W0401
18 Side cover *   25R8836
Side cover with lock *   25R8859
19 Power supply, 401 watt     39Y7330
20 Memory, 512MB *   41Y2725
21 System fan, rear   * 25R8829
  PSU adapter bracket (not shown)   * 42C7509

7042-C07 parts listed in the following table are not illustrated.

Table 11. 7042-C07 parts listing (continued)
Description Tier 1 CRU Tier 2 CRU Part number
3.0 V battery   * 33F8354
Bezel kit *   13N2450
Cable, 18-inch SATA signal   * 39Y9810
Cable, 401 watt DAS   * 25R8849
EMC shield kit *   13N2997
EMC I/O shield *   25R8843
System service label *   44E7281
Keylock, keyed-random   * 26K7364
Cable, panel mount assembly, SATA   * 13N2413
Cable, IDE signal   * 13N2466
Cable, serial port 2 *   42C1053
EMC shield kit *   13N2997
PCI-X SCSI Enablement Card *   44E4851
Mouse, 2-button *   03N6669
Kit, bezel *   13N2450
Support and hold down brackets *   41Y9086
Retainer kit (for optical and diskette drives) *   39R9369
Retention module, fan sync     25R8873
Stabilizing feet *   13N2985
C2 switch   * 39Y9783
Miscellaneous tray kit (clip, insulator, retainer) *   39Y9773
Modem cable (see HMC modem cable part numbers)      

For a more complete listing of power cords for the HMC, see Planning for power .

7042-C08 parts

Machine type 7042-C08 uses a personal computer machine type of 7946-52U for its base configuration. To access the personal computer hardware maintenance manuals, see Personal computer parts.

Note: Each PC hardware maintenance manual might reference more than one machine type in its title. If necessary, to cross-reference to the original PC hardware maintenance manual, make sure that you find the hardware maintenance manual for the PC machine type and model for the HMC that you are servicing.

The following illustration and table identifies the major components that make up model 7042-C08.

Figure 7. Model 7042-C08 parts
7042-C08 parts
Notes:
  1. Field replaceable units (FRUs) must be serviced only by an authorized service provider.
  2. Customer replaceable units (CRUs) can be replaced by the customer. Definitions of tier 1 and tier 2 CRUs for this model HMC follow:
    Tier 1 CRU
    A procedure that a customer can perform without input from a service provider. The procedure used to service this type of component is usually required to be done by the customer.
    Tier 2 CRU
    A procedure that a customer can perform, but might require support from a service provider. The procedure used to service this component is not usually required to be done by the customer.
  3. If the part you are replacing is not identified as being either tier 1 or tier 2, call your service provider to service the FRU.
Table 12. 7042-C08 parts listing.

7042-C08 parts listing

Index Description Tier 1 CRU Tier 2 CRU Part number
1 Chassis assembly     49Y8457
2 Operator Information panel assembly   49Y8456  
3 Front USB connector assembly   49Y8449  
4 DVD-RAM Drive, SATA 43W8467    
4 DVD-ROM Drive, SATA 43W8466    
5 Bezel Kit 13N2450    
6 Bezel, upper 49Y8453    
7 Bezel, lower 49Y8454    
8 Hard disk drive, SATA, 3.5- inch 250 GB, fixed/simple-swap, with tray (optional) 39M4511    
8 Hard disk drive, SATA, 3.5-inch 500 GB, fixed/simple-swap, with tray (optional) 39M4517    
8 Hard disk drive, 160 GB (optional) 39M4525    
8 Hard disk drive, 250 GB SATA (optional) 39M4529    
8 Hard disk drive, SATA, 3.5- inch 750 GB, fixed/simple-swap, with tray (optional) 43W7575    
8 Hard disk drive, SATA, 3.5-inch 500 GB, 10K, hot-swap, with tray (optional) 39M4533    
8 Hard disk drive, SATA, 3.5-inch 750 GB, 10K, hot-swap, with tray (optional) 43W7579    
8 Hard disk drive, SAS, 3.5-inch 146 GB, 15K, hot-swap, with tray (optional) 39R7350    
9 Retention bracket (front), adapter   13N2993  
10 Hard disk drive cage, 3.5-inch drives 49Y8451    
10 Hard disk drive cage, 2.5-inch drives     49Y8460
11 SAS/SATA hard disk drive backplane (for 3.5-inch drive cage)   49Y4462  
SATA backplate, simple-swap 25R8842    
12 Hard disk drive fan assembly (for 3.5-inch drive cage)   39Y9860  
13 System board assembly     69Y1013
14 ServeRAID-BR10il v2 SAS/SATA controller     49Y4737
15 Microprocessor, Xeon 2.93 GHz, 1333MHz-9MB Processor     46C6775
Microprocessor, Xeon 2.4 GHz, 1333MHz-8MB, 4C, (models C2x and C2Y)     49Y4647
Microprocessor, Xeon 2.53 GHz, 1333MHz-8MB, 4C, (models 42x and 42Y)     49Y4648
Microprocessor, Xeon 2.67 GHz, 1333MHz-8MB, 4C, (models 52x and 52Y)     49Y4649
Microprocessor, Xeon 2.8 GHz, 1333MHz-8MB, 4C, (models 62x and 62Y)     49Y4668
16 Fan sink     49Y8390
17 Side cover with lock 49Y8447    
18 Retention bracket (rear), adapter   49Y8450  
19 Power supply, non-redundant 401 watt     46M6678
20 Memory, 1 GB single-rank PC3-10600R-999 DDR3 ECC RDIMM 44T1490    
Memory, 2 GB single-rank PC3-10600R-999 DDR3 ECC RDIMM 44T1582    
Memory, 2 GB dual-rank PC3-10600R-999 DDR3 ECC RDIMM 44T1491    
Memory, 4 GB dual-rank PC3-10600R-999 DDR3 ECC RDIMM 44T1598    
Memory, 1 GB dual-rank PC3-10600R-999 DDR3 ECC UDIMM 44T1572    
Memory, 2 GB dual-rank PC3-10600R-999 DDR3 ECC UDIMM 44T1573    
Memory, 2 GB single-rank PC3-10600R-999 DDR3 ECC UDIMM 44T1574    
Memory, 4 GB quad-rank 1 Gbit DDR3-1066 RDIMM 46C7452    
21 System fan, rear   49Y8445  

The 7042-C08 parts that are listed in the following table are not illustrated.

Table 13. 7042-C08 parts listing (continued)
Description Tier 1 CRU Tier 2 CRU Part number
ServeRAID-MR10i adapter 43W4296    
ServeRAID-MR10is VAULT adapter 44E8695    
NetXtreme II 1000 Express Ethernet Adapter 39Y6070    
Cable, backplane configuration (3.5-inch hot-swap hard disk drive)   49Y8448  
Cable, SAS signal (3.5-inch hot-swap hard disk drive)   46M6498  
Cable, SATA signal (3.5-inch simple-swap hard disk drive)   49Y8444  
Cable 1Mx4 SAS-Mini   39R6530  
Cable 3Mx4 SAS-Mini   39R6532  
Cable, optical disk drive/tape drive   25R5635  
EMC shield 49Y8455    
EMC shield kit, optical disk drive/tape drive 13N2997    
Feet, chassis 13N2985    
Hard disk drive carrier, 3.5-inch simple-swap 42C7495    
Hard disk drive shield 44X0388    
Keyboard, US 42C0060    
Keylock, keyed-alike   26K7363  
Keylock, keyed-random   26K7364  
Kit, Retainer (for optical and diskette drives) 39R9369    
Power supply unit adapter 42C7509    
Miscellaneous parts kit 39Y9773    
Mouse, 2-button 39Y9875    
Mouse, optical, 3-button (optional) 40K9203    
Power supply cage, 430 watt     49Y8459
Retention module (for fan sink)     49Y8458
Side/top cover 49Y8446    
System service label 49Y8452    
USB hypervisor key 44M2234    
Virtual media key 46C7532    
Modem cable (see HMC modem cable part numbers)      

For a more complete listing of power cords for the HMC, see Planning for power.

HMC keyboard CRUs

The keyboards identified in the following table can be attached to any HMC.

Notes:
  1. All keyboards are considered a Tier 1 CRU.
  2. You must have the specific character set designed for each language installed on your HMC.
Keyboard country code FRU/CRU part number
US English 10N6956
Arabic 10N6984
Belgian/French 89P8302
Belgian/UK 10N6969
Bulgarian 10N6972
Brazilian Portuguese 10N6963
Chinese/US 10N6966
Czech 10N6981
Danish 10N6971
Dutch 10N6975
English/EMEA 10N6988
French 10N6957
French Canadian 445 10N6967
French Canadian 58 10N6968
German 10N6959
Greek 10N6977
Hebrew 10N6978
Hungarian 10N6964
Icelandic 89P8317
Italian 141 89P8318
Italian 142 10N6958
Japanese 194 10N6962
Korean 10N6965
LA Spanish 10N6983
Norwegian 10N6974
Polish 10N6979
Portuguese 10N6976
Romanian 89P8326
Russian 10N6986
Russian/Cyrillic 89P8328
Serbian/Cyrillic 89P8329
Slovak 10N6980
Spanish 10N6961
Swedish/Finnish 10N6870
Swiss/French/German 10N6973
Thailand 89P8334
Turkish 440 10N6982
Turkish 179 89P8336
UK English 10N6960
US 89P8338
Yugoslav/Latin 89P8339

HMC modem cable part numbers

The following tables contain part number information for HMC modem cables, along with the name of the country or region where used, and a listing of countries along with the telephone cable name and part number where used.

If you are using a cable other than one of the cables listed in the following table, read the following caution statement.

Note: For a more complete listing of power cords for the HMC, see Planning for power.
CAUTION:
To reduce the risk of fire, use only No. 26 AWG or larger (for example, 24 AWG) UL-listed or CSA certified telecommunication line cord. (C035)
Primary country or region Cable name Cable part number
Austria AUS 21H4902
Australia AUZ 75G3807
Belgium BEL 21H4903
Denmark DN 75G3812
Finland FN 75G3809
France FR 75G3803
Germany GE 75G3804
Hong Kong S.A.R. of the PRC HK 75G3808
Israel ISR 21H4905
Italy IT 75G3802
Netherlands NL 75G3810
South Africa SAF 21H4904
Sweden SW 75G3806
Switzerland SZ 75G3811
United Kingdom UK 75G3805
United States US 87G6236

External modems

Contains a list of external modem part number along with the primary country or region where used.

Primary country or region Modem part number
United States 03N7035
Australia 03N7036
Europe 03N7037
United Kingdom 03N7038
China 03N7039
Taiwan 03N7040
All geographies 03N7041

Internal modem

When ordering a replacement internal modem for HMC models 7042-CR5, 7042-CR6, or 7042-CR7, use part number 45D3866. For other HMC models, use part number 80P4702.

Power cords

The manufacturer provides a power cord with a grounded attachment plug to use with this product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet.

Power cords used in the United States and Canada are listed by Underwriter's Laboratories (UL) and certified by the Canadian Standards Association (CSA).

  • For units intended to be operated at 115 volts: Use a UL-listed and CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length and a parallel blade, grounding-type attachment plug rated 15 amperes, 125 volts.
  • For units intended to be operated at 230 volts (within the US): Use a UL-listed and CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length and a tandem blade, grounding-type attachment plug rated 15 amperes, 250 volts.
  • For units intended to be operated at 230 volts (outside the US): Use a cord set with a grounding-type attachment plug. The cord set should have the appropriate safety approvals for the country in which the equipment will be installed.
  • The power cords listed in the following table are specifically designed for a country or region and are usually available only in that country or region.
Note: All power cords are considered a Tier 1 CRU.
Front view of power cords
Index Power cord part number Used in these countries and regions
1 1838574 Thailand, Bahamas, Barbados, Bolivia, Brazil, Canada, Costa Rica, Dominican Republic, Ecuador, El Salvador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Netherlands Antilles, Panama, Peru, Philippines, Taiwan, Trinidad (West Indies), Tobago, United States of America, Venezuela
2 6952301 Bahamas, Barbados, Bermuda, Bolivia, Brazil, Canada, Cayman Islands, Colombia, Costa Rica, Dominican Republic, Ecuador, El Salvador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Korea (South), Liberia, Mexico, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad (West Indies), United States of America, Venezuela
3 13F9940 Argentina, Australia, China (PRC), New Zealand, Papua New Guinea, Paraguay, Uruguay, Western Samoa
4 13F9979 Afghanistan, Algeria, Andorra, Angola, Austria, Belgium, Benin, Bulgaria, Burkina Faso, Burundi, Cameroon, Central African Rep., Chad, Czech Republic, Egypt, Finland, France, French Guiana, Germany, Greece, Guinea, Hungary, Iceland, Indonesia, Iran, Ivory Coast, Jordan, Lebanon, Luxembourg, Macao S.A.R. of the PRC, Malagasy, Mali, Martinique, Mauritania, Mauritius, Monaco, Morocco, Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland, Portugal, Romania, Senegal, Slovakia, Spain, Sudan, Sweden, Syria, Togo, Tunisia, Turkey, former USSR, Vietnam, former Yugoslavia, Zaire, Zimbabwe
5 13F9997 Denmark
6 14F0015 Bangladesh, Burma, Pakistan, South Africa, Sri Lanka
7 14F0033 Antigua, Bahrain, Brunei, Channel Islands, Cyprus, Dubai, Fiji, Ghana, Hong Kong S.A.R. of the PRC, India, Iraq, Ireland, Kenya, Kuwait, Malawi, Malaysia, Malta, Nepal, Nigeria, Polynesia, Qatar, Sierra Leone, Singapore, Tanzania, Uganda, United Kingdom, Yemen, Zambia
8 14F0051 Liechtenstein, Switzerland
9 14F0069 Chile, Ethiopia, Italy, Libya, Somalia
10 14F0087 Israel


Send feedback Rate this page

Last updated: Sun, December 17, 2017