subscribe iconSubscribe to this information
POWER7 information

Installing the factory-racked server

Use this information to learn about installing the factory-racked server.

To install a server that is already in a factory-installed rack, complete the following high-level tasks:

Table 1. Tasks to install the factory-racked server
Task Where to find associated information
Check the prerequisites. For instructions, see Prerequisite for installing the 8231-E1D, 8231-E2D, or 8268-E1D system.
Perform the inventory. For instructions, see Before you begin.
Remove the shipping bracket on the rear of the system that protects the power supplies. This is not needed for installation.
Note: Depending on your configuration, there might be orange shipping brackets on either side of the rear of the system and also covering the power supplies. Both must be removed.
To remove the shipping bracket, do the following:
  1. Remove the screws.
  2. Pull the power supplies out slightly so that you can remove the shipping bracket.
  3. Reseat the power supplies.
  4. If expansion units are present, remove the shipping brackets that cover the power supplies.
Graphic showing removing the shipping bracket
Connect your expansion unit, disk drives, and PCI adapters, if applicable.
Notes:
  • Consult your project manager or read the system plans before moving or installing any disk drives and PCI adapters.
  • Do not power on your system. You will be instructed to power on the system when you set up the console.
For instructions, see Connecting the expansion units, disk drives, and PCI adapters.
Cable the system and set up a console, interface, or terminal. For instructions, see Cabling the server and setting up the console.
Connect the power cables to the system and apply power. For instructions, see Connecting the power cables to the system.
Complete the server setup. For instructions, see Completing the server setup.


Send feedback | Rate this page