FI01141
FI01141 indicates that a loss of power to an IOP, to an internal device, or to an external device might have occurred.
Complete the following steps:
- Are 0000 xxxx, 1xxx xxxx, or A6xx 698x SRCs displayed on the control
panel?
- No: Continue with the next step.
- Yes: Use the SRC displayed on the control panel to diagnose the problem.
- Did the SRC that directed you to this FI code involve an externally
attached device or an IOP with an externally attached device?
- No: Continue with the next step.
- Yes: Verify that there is no obvious problem with power to the device. If you suspect a power problem with the device, go to the service information for that external device.
- The power supply cables or connections to internal disk units, tape units, or optical storage units might be the failing item. For part numbers, see Finding parts, locations, and addresses.