FI01141

FI01141 indicates that a loss of power to an IOP, to an internal device, or to an external device might have occurred.

Complete the following steps:

  1. Are 0000 xxxx, 1xxx xxxx, or A6xx 698x SRCs displayed on the control panel?
    • No: Continue with the next step.
    • Yes: Use the SRC displayed on the control panel to diagnose the problem.
  2. Did the SRC that directed you to this FI code involve an externally attached device or an IOP with an externally attached device?
    • No: Continue with the next step.
    • Yes: Verify that there is no obvious problem with power to the device. If you suspect a power problem with the device, go to the service information for that external device.
  3. The power supply cables or connections to internal disk units, tape units, or optical storage units might be the failing item. For part numbers, see Finding parts, locations, and addresses.