Choosing the recovery procedure for a disk failure or disk errors
Use this information to determine the actions that you need to take when you recover your system because of a failed or damaged disk unit.
The steps you follow to recover from a disk failure depend on the following items:
- What unit failed.
- Whether disk protection, such as device parity protection or mirrored protection is active.
- Whether you have user auxiliary storage pools (ASPs) configured.
- Whether some or all of the sectors on the disk are damaged. If a disk unit must be replaced, a service representative normally tries to copy the information from the disk unit when it is replaced. This procedure is sometimes referred to as a disk pump.
Use Table 1 to determine what recovery procedure you should follow, based on the failure that has occurred on your system. To find your situation on the chart, ask your service representative whether data was copied successfully (the results of the disk pump).
Service representative terminology | Terminology in recovery charts |
---|---|
Full pump | None of the data is lost |
Partial pump | Some of the data is lost |
Could not pump | All of the data is lost |
Recovery for disk errors that do not require disk replacement: Some
types of disk units automatically recover from errors without needing to be
replaced. In some cases, however, sectors are damaged before the disk unit
reassigns them and some object damage occurs. If you receive a message indicating
that object damage has occurred and disk sectors have been reassigned, consider
this to be the value Some
for the column Data loss on
the failed unit in Table 1.
- Begin at the task immediately following
Attach the new disk unit
. - If the checklist contains a task called,
Restore the disk unit data
, skip that task.
Type of unit that failed | Data loss on failed unit | Availability protection on failed unit | User APSs configured? | Procedure to follow |
---|---|---|---|---|
Any | N/A | Mirrored protection | N/A 1 | Checklist 14: Actions for non-load source disk unit failure |
Any | N/A | Device parity protection | N/A 1 | Checklist 15: Actions for non-load source disk unit failure |
Load source unit | None | None | N/A 1 | Checklist 1: Actions for load-source disk unit failure |
Load source unit | Some2 | None | N/A 1 | Checklist 2: Actions for load-source disk unit failure |
Load source unit | All | None | No | Checklist 3: Actions for load-source disk unit failure |
Load source unit. No basic ASPs in overflowed status3 | All | None | Yes | Checklist 4: Actions for load-source disk unit failure |
Load source unit. One or more basic ASPs in overflowed status3. | All | None | Yes | Checklist 5: Actions for load-source disk unit failure |
Non-Load source unit in system ASP4 | None | None | N/A 1 | Checklist 6: Actions for non-load source disk unit failure or disk units in basic user auxiliary storage pool disk failure |
Non-Load source unit in system ASP4 | Some2 | None | N/A 1 | Checklist 7: Actions for non-load source disk unit failure |
Non-Load source unit in system ASP4 | All | None | No | Checklist 8: Actions for non-load source disk unit failure |
Non-Load source unitin system ASP4. No basic ASPs in overflowed status3. | All | None | Yes | Checklist 9: Actions for non-load source disk unit failure |
Non-Load source unit in system ASP4. One or more basic ASPs in overflowed status3. | All | None | Yes | Checklist 10: Actions for non-load source disk unit failure |
Disk unit in basic ASP | None | None | Yes | Checklist 6: Actions for non-load source disk unit failure or disk units in basic user auxiliary storage pool disk failure |
Disk unit in basic ASP | Some2 | None | Yes | Checklist 11: Actions for a failure in a basic auxiliary storage pool disk unit |
Disk unit in basic ASP. Failed unit not in overflowed status3. | All | None | Yes | Checklist 12: Actions for a failure in a basic auxiliary storage pool disk unit |
Disk unit in basic ASP. Failed unit in overflowed status3. | All | None | Yes | Checklist 13: Actions for a failure in a basic auxiliary storage pool disk unit |
Disk unit in independent ASP | None | None | Yes | Checklist 17: Actions for independent auxiliary storage pool disk failure |
Disk unit in independent ASP | Some2 | None | Yes | Checklist 18: Actions for a failure in an independent auxiliary storage pool disk unit |
Disk unit in independent ASP | All | None | Yes | Checklist 19: Actions for a failure in an independent auxiliary storage pool disk unit |
Cache storage in input/output processor (IOP) | Some | N/A | N/A1 | Checklist 23: Actions for a failed cache card |
|