8202-E4B or 8205-E6B SAS dual-RAID subsystem with internal drives

This configuration uses dual-storage I/O adapter (IOA) mode or high availability (HA) RAID mode with internal disk drives.

This configuration increases availability using dual-storage IOA or high availability (HA) to connect multiple adapters to a common set of internal disk drives. It also increases the performance of RAID arrays. The following rules apply to this configuration:

Example: SAS dual-RAID subsystem with internal drives

This example provides an overview of the dual-storage I/O adapter (IOA) configuration using internal disk drives on the 8202-E4B or 8205-E6B system.
Figure 1. Disk bays controlled by both embedded SAS adapters when using SAS dual-RAID subsystem with internal drives
Disk bays controlled by both embedded SAS adapters when using SAS dual-RAID subsystem with internal drives
The following table lists the configuration details.
Table 1. Configuration details
Embedded SAS Configuration details

RAID enablement card

RAID/Cache storage controller

Cache battery card

  • RAID enablement card (CCIN 2BE1) in tandem with separate cache battery card (CCIN 2BCF) creates a RAID adapter.
  • The RAID controller card with cache battery card attached (CCIN 2BD9) provides another RAID adapter.
  • The two SAS adapters connect to all eight disk drives.
  • Physical connections to the SAS cable are enabled in order to attach to another SAS port expander in an external disk enclosure using a YI cable.