AIB0016I SYSAIB CTRACE DEFINITION FAILED. RC=rc, RSN=rsn
Explanation
The system cannot define the SYSAIB component trace.
In the message text:
- rc
- The return code provided by the CTRACE DEFINE macro.
- rsn
- The reason code provided by the CTRACE DEFINE macro.
System action
The system runs without the SYSAIB component trace.
Operator response
Notify the system programmer.
System programmer response
Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM Support Center.
Problem determination
For information about the CTRACE return and reason codes, see CTRACE macro in z/OS MVS Programming: Authorized Assembler Services Reference ALE-DYN.
Source
AI Base Component for IBM® z/OS®
Module
AIBCTIT
Routing code
2, *
Descriptor code
5