077
Explanation
While the system was processing a console service request, an error occurred.
- xxxx
- This halfword is for IBM® internal use only.
- yyyy
- This halfword is the unique reason code identifier.
- Code
- Explanation
- 0000
- In a request to start or stop MONITOR JOBNAMES, STATUS, or SESSIONS processing, the caller passed an incorrect console name or address space identifier (ASID).
- 0010
- The parameter list passed was not valid.
- 0014
- A caller was not running in the Console address space.
- 001C
- The system could not process a console request because of conflicting requests in the parameter list.
- 0020
- The system could not process a console request because of incomplete or incorrect data in the parameter list.
- 0024
- The system could not process a console request because the specified console was not dedicated to the requesting component.
- 0028
- The system encountered an error in CommTask processing.
- 002C
- The SMCS logical error exit determined that there was a logical error associated with a SMCS console session.
- 002D
- SMCS could not initialize or a session with an LU could not be established. Message IEE052I or IEE053I has been issued with more specific information.
- 002E
- An unexpected condition has occurred in SMCS attempting to establish a session with an LU. Message IEE053I or IEE057I may be issued with more specific information.
- 002F
- A storage overlay within DIDOCS has been detected.
- 0030
- A storage overlay within SMCS has been detected. SMCS will continue; however, performance may be degraded.
- 0032
- Appropriate ENQ serialization could not be obtained during system partitioning.
- 0038
- UCME look-up error. Either the requested UCME could not be located, or the console ID supplied for the look-up was invalid.
- 003C
- IEEVARYD found a parameter or option that is not valid.
- 003D
- The CnzConv service was unable to process the request made by the caller. The caller invoked a service in AR mode with a non-zero ALET associated with the input parameter list. The service however requires that input parameter list is addressable from the primary address space.
- 0400 – 3FFF
- These codes are for IBM internal use only, with the
following exceptions:
- 0828
- All IXCMSGOs failed. IXCMSGO is the method by which Console services use XCF to send information to other systems in the sysplex. The failure is likely due to XCF buffer constraints on one or more systems. Check SYSLOG for message CNZ2202E that might provide additional information about the abend.
- 0A08
- A subsystem console request was made to module IEAVG700 with a subsystem console service routine parameter list (SCSR mapped in macro IEZVG100) with a version value in field SCSVER that is no longer supported.
- 0F00
- An unexpected return code was received from the IXCMSGO service while sending information to other systems in the sysplex.
System action
If the error occurred during MONITOR or STOPMN command processing, the MONITOR function is not changed. Otherwise, the system abnormally ends the calling routine.
- Reason code
- System action
- 003C
- The IEEVARYD service returns return code X'10'.
- 003D
- The service called is unable to process the request.
Operator response
If the error occurred during MONITOR command processing, reenter the MONITOR or STOPMN command.
For other errors (including those designated as IBM internal use only), contact the system programmer.
System programmer response
Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM Support Center. Be prepared to provide any dump or issuance of message CNZ0001I that occurred around the time of the ABEND.
Programmer response
- Reason code
- Application programmer response
- 0000
- Correct the console name or address space identifier and issue the MONITOR request again.
- 001C
- Correct the function request bits in the subsystem console service routine parameter list so that there are no conflicting requests and issue the subsystem console request again.
- 0020
- Correct the subsystem console service routine parameter list data and issue the subsystem console request again.
- 0024
- Correct the console in the subsystem console service routine parameter list and issue the request again.
- 0038
- Correct the console ID and retry the UCME lookup.
- 003C
- Correct the program invoking the IEEVARYD service. If the VDEV_ENQS_HELD flag (found in the IEEZB833 mapping) is being used, the code must be updated to remove this option (it is no longer supported), and to release the ENQ serialization required to bring the device online (that is, SYSIEFSD.VARYDEV and SYSIEFSD.Q4).
- 003D
- Correct the program that called the CNZCONV service so that the request can be successfully completed.
- 0A08
- Update the application to use a Subsystem Console Service Routine Parameter List that is supported and set SCSVER to the current version (constant SCSVERSN as defined in IEZVG100).
For other errors (including those described as IBM internal use only), contact the system programmer.
Source
Console services