Example 1:
SETSMS INTERVAL(020)
Example 2:
SETSMS DESELECT(ALL),TRACE(ON),SIZE(16K)
SETSMS SELECT(ACSINT,CDSC,CONFC)
DISPLAY SMS,TRACE
10.24.04 DISPLAY SMS
IGD002I 11:08:57 DISPLAY SMS 056
TRACE = ON SIZE = 128K TYPE = ERROR
JOBNAME = * ASID = *
TRACING EVENTS:
MODULE = ON SMSSJF = ON SMSSSI = ON ACSINT = ON
OPCMD = ON CONFC = ON CDSC = ON CONFS = ON
MSG = ON ERR = ON CONFR = ON CONFA = ON
ACSPRO = ON IDAX = ON DISP = ON CATG = ON
VOLREF = ON SCHEDP = ON SCHEDS = ON VTOCL = ONVTOCD = ON
VTOCR = ON VTOCC = ON VTOCA = ON
RCD = ON DCF = ON DPN = ON TVR = ON
DSTACK = ON UAFF = ON
VOLSELMSG = (OFF,0) TYPE = ERROR JOBNAME = *
ASID = * STEPNAME = *
DSNAME = *
Example 3:
SETSMS SELECT(MODULE,DSTACK,VTOCC)
Example 4:
SETSMS AKP(300)
SETSMS AKP(300)
IGW467I DFSMS TVS ACTIVITY KEY POINT PARMLIB VALUE 959
CHANGED ON SYSTEM: SYSTEM1
OLD VALUE: 200
NEW VALUE: 300
Example 5:
SETSMS QTIMEOUT(500)
SETSMS QTIMEOUT(500)
IGW467I DFSMS TVS QTIMEOUT PARMLIB VALUE 962
CHANGED ON SYSTEM: SYSTEM1
OLD VALUE: 400 1
NEW VALUE: 500 1
Example 6:
SETSMS MAXLOCKS(200,100)
SETSMS MAXLOCKS(200,100)
IGW467I DFSMS TVS MAXLOCKS PARMLIB VALUE 965
CHANGED ON SYSTEM: SYSTEM1
OLD VALUE: 100 50 1
NEW VALUE: 200 100 1
These MAXLOCKS values are for example only. In practice, you might want to set the minimum and increment values higher to avoid generating too many messages.
Example 7:
SETSMS VOLSELMSG(ON,ALL) TYPE(ERROR)
After the processing
completes, check the parameter settings, enter:DISPLAY SMS,VOLSELMSG
This
results the following report:IGD002I 08:14:24 DISPLAY SMS 488
VOLSELMSG = (ON,ALL) TYPE = ERROR JOBNAME = *
ASID = * STEPNAME = *
DSNAME = *
TRACE = ON SIZE = 128K TYPE = ERROR
JOBNAME = * ASID = *
Note that because the TYPE parameter
value is shared by SMS trace facility and volume selection analysis
messages, changing it for volume selection analysis messages will
therefore affect SMS tracing.