This section of the listing documents the source statements of
the module and the resulting object code.
This section is the most useful part of the listing because it
gives you a copy of all the statements in your source program (except
listing control statements) exactly as they are entered into the machine.
You can use it to find simple coding errors, and to locate and correct
errors detected by the assembler. By using this section with the
Ordinary Symbol and Literal Cross Reference section, you can check
that your branches and data references are in order. The location
counter values and the object code listed for each statement help
you locate any errors in a storage dump. Finally, you can use this
part of the listing to check that your macro instructions have been
expanded properly.
On z/OS and CMS, the assembler can produce two formats of the Source
and Object section: a 121-character format and a 133-character format.
To select one, you must specify either the LIST(121) assembler option
or the LIST(133) assembler option. Both sections show the source
statements of the module, and the object code of the assembled statements.
The 133-character format shows the location counter, and the first
and second operand addresses (ADDR1 and ADDR2) as 8-byte fields in
support of 31-bit addresses. This format is required when producing
the generalized object format data set (see GOFF (z/OS and CMS)). The 133-character format also
contains the first eight characters of the macro name in the identification-sequence
field for statements generated by macros. Figure 1 shows
an example of the Source and Object section of the listing. This section
shows the source statements of the module, and the object code of
the assembled statements.
High Level Assembler lets you write your program, and print the
assembler listing headings, in mixed-case. Diagnostic messages are
printed in the language you specify in the LANGUAGE assembler option
described in LANGUAGE.
Figure 1 shows an example of the Source
and Object section in 121-character format, and in mixed-case. Figure 1. Source and object listing section—121 format 1 2
SAMP01 Sample Listing Description Page 3
Active Usings: None
3 4 5 6 7 8 9
Loc Object Code Addr1 Addr2 Stmt Source Statement HLASM R6.0 2008/07/11 17.48
000000 00000 000E0 2 Samp01 Csect
22 Entry1 SAMPMAC Parm1=YES 00002300
000000 18CF 23+Entry1 LR 12,15 01-SAMPM
24+ ENTRY Entry1 01-SAMPM
12
R:C 00000 25+ USING Entry1,12 Ordinary Using 01-SAMPM
000002 0000 0000 00000 26+ LA Savearea,10 01-SAMPM
10 ** ASMA044E Undefined symbol - Savearea
10 ** ASMA029E Incorrect register specification - Savearea
11 ** ASMA435I Record 6 in SAMP01 MACLIB A1(SAMPMAC) on volume: EAR191
000006 50D0 A004 00004 27+ ST 13,4(,10) 01-SAMPM
00000A 50A0 D008 00008 28+ ST 10,8(,13) 01-SAMPM
00000E 18DA 29+ LR 13,10 01-SAMPM
R:A35 00010 30+ USING *,10,3,5 Ordinary Using,Multiple Base 01-SAMPM
** ASMA303W Multiple address resolutions may result from this USING and the USING on statement number 25 13
** ASMA435I Record 10 in SAMP01 MACLIB A1(SAMPMAC) on volume: EAR191
14
31+ DROP 10,3,5 Drop Multiple Registers 01-SAMPM
32 COPY SAMPLE 00002400
33=* Line from member SAMPLE
C 02A 00000 0002A 34 Using IHADCB,INDCB Establish DCB addressability 00002500
C 07A 00000 0007A 35 ODCB Using IHADCB,OUTDCB 00002600
36 push using 00002700
15
R:2 00000 37 PlistIn Using Plist,2 Establish Plist addressability 00002800
R:3 00000 38 PlistOut Using Plist,3 00002900
SAMP01 Sample Listing Description Page 4
16 Active Usings (1):Entry1,R12 IHADCB(X'FD6'),R12+X'2A' PlistIn.plist,R2 PlistOut.plist,R3
ODCB.IHADCB(X'F86'),R12+X'7A'
Loc Object Code Addr1 Addr2 Stmt Source Statement HLASM R6.0 2008/07/11 17.48
000010 1851 40 ?Branch LR R5,R1 Save Plist pointer 00003100
** ASMA147E Symbol too long, or first character not a letter - ?Branch
** ASMA435I Record 30 in SAMP01 ASSEMBLE A1 on volume: EAR191
000012 5820 5000 00000 41 L R2,0(,R5) R2 = address of request list 00003200
000016 47F0 C022 00022 42 B Open 00003300
697 End 00055100
0000D0 00000001 698 =f'1'
0000D4 00000000 699 =V(RCNVDATE)
0000D8 00000000 700 =V(RCNVTIME)
0000DC 00000002 701 =f'2'
- 1
- The deck identification, if any, consisting of 1–8 characters.
It is obtained from the name field of the first named TITLE statement.
The assembler prints the deck identification and date on every page
of the listing except the Options Summary.
- 2
- The information taken from the operand field of a TITLE statement.
- 3
- Location field. This field is the value of the location counter
that represents the assembled address (in hexadecimal notation) of
the object code.
- For ORG statements, the value of the location counter before the
ORG is placed in the location column, and the value of the location
counter after the ORG is placed in the Addr2 field.
- If the END statement contains an operand, the operand value (requested
entry point) appears in the location field.
- In the case of LOCTR, COM, CSECT, RSECT, and DSECT statements,
the location field contains the current address of these control sections.
- In the case of EXTRN, WXTRN, ENTRY, and DXD instructions, the
location field and object code field are blank.
- For LTORG statements, the location field contains the location
assigned to the literal pool.
If, at the time of the page eject,
the current control section being assembled is a COM section, the
heading line starts with C-LOC. If, at the time of the page eject,
the current control section being assembled is a DSECT, the heading
line starts with D-LOC. If, at the time of the page eject, the current
control section being assembled is an RSECT, the heading line starts
with R-LOC.
- 4
- The object code produced by the source statement. The entries,
which are shown left-aligned and in hexadecimal notation, are machine
instructions or assembled constants. Machine instructions are printed
in full with a space inserted after every four digits (2 bytes). Only
the first 8 bytes of a constant appears in the listing if PRINT NODATA
is in effect, unless the statement has continuation records. The
whole constant appears if PRINT DATA is in effect. (See "PRINT instruction" in
the HLASM Language Reference.)
This field also shows the base registers for ordinary USING instructions,
and the base register and displacement for dependent USING instructions.
See 12 and 15 for
more details.
- 5
- Effective addresses (each the result of adding a base register
value and a displacement value):
- The field headed Addr1 contains the effective address for the
first operand of an instruction (if applicable). It also contains:
- For a USING instruction, the value of the first operand.
- For a CSECT, START, LOCTR, or RSECT instruction, the start address
of the control section.
- For an ORG instruction, the value of the location counter before
the ORG.
- For an EQU instruction, the value assigned.
- The field headed Addr2 contains the effective address of the last
operand of any instruction referencing storage.
- For a USING instruction, the Addr2 field contains the value of
the second operand.
- For a CSECT, START, LOCTR, or RSECT instruction, the Addr2 field
contains the end address of the control section.
- For an ORG instruction, the Addr2 field contains the next address
as specified by the operand field.
- For an EQU instruction, the Addr2 field contains the length assigned.
If the assembler option LIST(121)
is in effect, both address fields contain six digits; however, if
the high-order digit is 0, it is not printed. If the assembler option
LIST (133) is in effect, both address fields contain eight digits.
For USING and EQU instructions, the Addr2 field can contain up to
eight digits.
- 6
- The statement number. The column following the statement number
contains one of these values:
- A plus sign (+) indicates that the statement was generated as
the result of macro call processing.
- An unnumbered statement with a plus sign (+) is the result of
open code substitution.
- A minus sign (-) indicates that the statement was read by a preceding
AREAD instruction.
- An equals sign (=) indicates that the statement was included by
a COPY instruction.
- A greater-than sign (>) indicates that the statement was generated
as the result of a preceding AINSERT instruction. If the statement
is read by an AREAD instruction, this takes
precedence and a minus sign is printed.
- 7
- The source program statement. The following items apply to this
section of the listing:
- Source statements are listed, including those
brought into the program by the COPY assembler instruction, and including
macro definitions submitted with the main program for assembly. Listing
control instructions are not printed, except for PRINT, which is printed
unless the NOPRINT operand is specified.
- Macro definitions obtained from a library are not listed, unless
the macro definition is included in the source program with a COPY
statement, or the LIBMAC assembler option was specified.
- The statements generated as the result of a macro instruction
follow the macro instruction in the listing, unless PRINT NOGEN is
in effect. If PRINT GEN is in effect and PRINT NOMSOURCE is specified,
the printing of the source statements generated during macro processing
and conditional assembly substitution is suppressed, without suppressing
the printing of the generated object code of the statements. If PRINT
MCALL is in effect, nested macro instructions including all parameters
are printed. When the PRINT NOGEN instruction is in effect, the assembler
prints one of the following on the same line as the macro call or
model statement:
- The object code for the first instruction generated
- The first 8 bytes of generated data from a DC instruction
When the assembler forces alignment
of an instruction or data constant, it generates zeros in the object
code and prints only the generated object code in the listing. When
you use the PRINT NOGEN instruction the generated zeros are not printed.
Diagnostic
Messages and Generated Data: If the next line to print after a
macro call or model statement is a diagnostic message, the generated
data is not shown.
- Assembler and machine instruction statements in the source program
that contain variable symbols are listed twice: first, as they appear
in the source input, and second, with values substituted for the variable
symbols. See Figure 2 for an example of
this.
- All error diagnostic messages appear in
line except those suppressed by the FLAG option. Diagnosing assembly errors describes how error messages and MNOTEs
are handled.
- Literals that have not been assigned locations by LTORG statements
appear in the listing following the END statement. Literals are identified
by the equal sign (=) preceding them.
- Whenever possible, a generated statement is printed in the same
format as the corresponding macro definition (model) statement. The
starting columns of the operation, operand, and comments fields are
preserved, unless they are displaced by field substitution, as shown
in Figure 2.
Figure 2. Source and object listing
section Loc Object Code Addr1 Addr2 Stmt Source Statement HLASM R6.0 2008/07/11 17.48
1 &A SETC 'abcdefghijklmnop' 00001000
2 &A LA 4,1 Comment 00002000
000000 4140 0001 00001 +abcdefghijklmnop LA 4,1 X00002000
+ Comment
3 &b SETC 'abc' 00003000
4 &b LA 4,1 Comment 00004000
000004 4140 0001 00001 +abc LA 4,1 Comment 00004000
It is possible for a generated statement to occupy ten or more
continuation lines on the listing. In this way, generated statements
are unlike source statements, which are restricted to nine continuation
lines. - 8
- The release level of High Level Assembler.
- 9
- The date and time at the start of the assembly.
- 10
- The error diagnostic messages immediately follow the source statement
in error. Many error diagnostic messages include the segment of the
statement that is in error. You can use the FLAG assembler option
to control the level of diagnostic messages displayed in your listing.
- 11
- The informational message, ASMA435I, that describes the origin
of the source statement in error. This message is only printed when
you specify the FLAG(RECORD) assembler option.
If the input data
set containing the source in error is a z/OS UNIX System Services
file, message ASMA435I can continue over more than one print line.
If the inclusion of the path name in the message causes the message
to be more than 255 bytes in length, the message is truncated. Figure 3. Example showing truncation
of long ASMA435I message Loc Object Code Addr1 Addr2 Stmt Source Statement HLASM R6.0 2008/07/11 17.48
000004 5810 0001 00001 6 l 1,1
** ASMA309W Operand 1 resolved to a displacement with no base register
** ASMA033I Storage alignment for 1 unfavorable
** ASMA435I Record 6 in /u/carland/assembler/source/dataset.which/has/a.very/longname/thus/causing/this/message/tobe/prin
ted/OVER/more/than/one/line/ on volume:
- 12
- The Addr1 and Addr2 columns show the first and second operand
addresses in the USING instructions. The base registers on an ordinary
USING instruction are printed, right-aligned in the object code columns,
preceded by the characters “R:”.
- 11
- A second instance of the informational message ASMA435I (also
mentioned in 1 ). Conditional assembly
statements and comment statements contribute to the record count of
macro definitions, as suggested by the record number which is greater
than the number of generated statements.
- 14
- The identification-sequence field from the source statement. For
a macro-generated statement, this field contains information identifying
the origin of the statement. The first two columns define the level
of the macro call, where a level of 01 indicates
statements generated by the macro specified within the source code,
and higher level numbers indicate statements generated from macros
invoked from within a macro.
For a library macro call, the last
five columns contain the first five characters of the macro name.
For a macro whose definition is in the source program (including
one read by a COPY statement or by the LIBMAC assembler option), the
last five characters contain the line number of the model statement
in the definition from which the generated statement is derived.
This information can be an important diagnostic aid in analyzing output
resulting from macro calls within macro calls.
- 15
- The Addr1 and Addr2 columns show the first and second operand
addresses in the USING instructions. The resolved base displacement
for a dependent USING instruction is printed in the object code columns,
as register displacement, where register is
shown as a hexadecimal value.
- 16
- The current USING
PUSH level is printed after the heading and before the first active
USING. If the USING PUSH level is zero, it is not shown.
If PRINT
UHEAD or PCONTROL(UHEAD) has been specified, a summary of current
active USINGs is printed on up to four heading lines, following the
TITLE line on each page of the source and object section. The USINGs
listed are those current at the end of the
assembly of the last statement on the previous page of the listing,
with the following exceptions: - The USINGs summary shows the effect of the USING instruction when:
- It is the first statement in the source input data set, or
- It is the first statement on the new page
- The USINGs summary shows the effect of the DROP instruction when:
- It is the first statement in the source input data set, or
- It is the first statement on the new page
Current active USINGs include
USINGs that are temporarily overridden. In the following example,
the USING for base register 12 temporarily overrides the USING for
base register 10. After the DROP instruction, the base register for
BASE1 reverts to register 10. USING BASE1,10
USING BASE1,12 Temporarily overrides register 10
LA 1,BASE1 Uses base register 12
DROP 12
LA 1,BASE1 Uses base register 10
The
summary of active USINGs heading lines have the format: Active Usings (n): label.sectname+offset(range),registers
where: - n
- Is the current PUSH level. If the PUSH level is zero, it is not
shown. If no USING statements are active, the heading appears as Active
Usings: None.
- label
- Is the label name specified for a Labeled USING. If the USING
is not labeled, this field is omitted.
- sectname
- Is the section name used to resolve the USING. The section name
is listed as (PC) if the section is an unnamed CSECT, (COM) if
the section is unnamed COMMON, and (DSECT) if the
section is an unnamed DSECT.
- offset
- Is the offset from the specified section that is used to resolve
the USING. This field is omitted if it is zero.
- (range)
- Is the number of bytes addressed by this base register for instructions
with 12-bit displacement fields. It is only shown if the default value
(any multiple of X'1000') is not used.
- registers
- Is the register or registers specified on the USING statement.
For dependent USINGs, the register is printed as register+offset where register is
the register used to resolve the address from the corresponding ordinary
USING, and offset is the offset from the
register to the address specified in the dependent USING.
If there are more
active USINGs than can fit into four lines, the summary is truncated,
and the character string 'MORE ...' is appended to the last line.
In Figure 4, the USINGs at statements 25 and 30
are ordinary USINGs. The USING at statement 34 is a dependent USING,
and that at statement 35 is a labeled dependent USING. The USINGs
at statements 37 and 38 are labeled USINGs.
Figure 4 also shows an example of the Source
and Object section when the same assembly is run with assembler
option LIST(133), and is followed by a description of differences
with respect to Figure 1: Figure 4. Source
and object listing section—133 formatSAMP01 Sample Listing Description Page 3
Active Usings: None
1
Loc Object Code Addr1 Addr2 Stmt Source Statement HLASM R6.0 2008/07/11 17.48
00000000 00000000 000000E0 2 Samp01 Csect
22 Entry1 SAMPMAC Parm1=YES 00002300
00000000 18CF 23+Entry1 LR 12,15 01-SAMPMAC
24+ ENTRY Entry1 01-SAMPMAC
2
R:C 00000000 25+ USING Entry1,12 Ordinary Using 01-SAMPMAC
00000002 0000 0000 00000000 26+ LA Savearea,10 01-SAMPMAC
** ASMA044E Undefined symbol - Savearea
** ASMA029E Incorrect register specification - Savearea
** ASMA435I Record 6 in SAMP01 MACLIB A1(SAMPMAC) on volume: EAR191
00000006 50D0 A004 00000004 27+ ST 13,4(,10) 01-SAMPMAC
0000000A 50A0 D008 00000008 28+ ST 10,8(,13) 01-SAMPMAC
0000000E 18DA 29+ LR 13,10 01-SAMPMAC
3
R:A35 00000010 30+ USING *,10,3,5 Ordinary Using,Multiple Base 01-SAMPMAC
** ASMA303W Multiple address resolutions may result from this USING and the USING on statement number 25
** ASMA435I Record 10 in SAMP01 MACLIB A1(SAMPMAC) on volume: EAR191
31+ DROP 10,3,5 Drop Multiple Registers 01-SAMPMAC
32 COPY SAMPLE 00002400
33=* Line from member SAMPLE
C 02A 00000000 0000002A 34 Using IHADCB,INDCB Establish DCB addressability 00002500
C 07A 00000000 0000007A 35 ODCB Using IHADCB,OUTDCB 00002600
36 push using 00002700
R:2 00000000 37 PlistIn Using Plist,2 Establish Plist addressability 00002800
R:3 00000000 38 PlistOut Using Plist,3 00002900
SAMP01 Sample Listing Description Page 4
Active Usings (1):Entry1,R12 IHADCB(X'FD6'),R12+X'2A' PlistIn.plist,R2 PlistOut.plist,R3
ODCB.IHADCB(X'F86'),R12+X'7A'
Loc Object Code Addr1 Addr2 Stmt Source Statement HLASM R6.0 2008/07/11 17.48
00000010 1851 40 ?Branch LR R5,R1 Save Plist pointer 00003100
** ASMA147E Symbol too long, or first character not a letter - ?Branch
** ASMA435I Record 30 in SAMP01 ASSEMBLE A1 on volume: EAR191
00000012 5820 5000 00000000 41 L R2,0(,R5) R2 = address of request list 00003200
00000016 47F0 C022 00000022 42 B Open 00003300
697 End 00055100
000000D0 00000001 698 =f'1'
000000D4 00000000 699 =V(RCNVDATE)
000000D8 00000000 700 =V(RCNVTIME)
000000DC 00000002 701 =f'2'
- 1
- The Addr1 and Addr2 columns show eight-character operand addresses.
- 2
- The assembled address of the object code occupies eight characters.
- 3
- The first eight characters of the macro name are shown in the
identification-sequence field.
|