- DDNAME=ddname
- Specifies the name of the in-stream data set that follows the
//*DATASET statement.
- MODE=E
- MODE=C
- Defines the card-reading mode.
- E
- Indicates that JES3 is to read the statements as EBCDIC with
validity checking. E is the default if the MODE parameter is omitted.
- C
- Indicates that JES3 is to read the statements in card image
form, that is, in column binary or data mode 2.
MODE=C is not valid
for jobs read from disk or tape, or for jobs submitted from remote
work stations.
- J=YES
- J=NO
- Indicates how JES3 is to recognize the end of the data set.
If
you specify MODE=C, JES3 ignores the J parameter; therefore, use
a //*ENDDATASET statement to end the data set - YES
- Indicates that a //*ENDDATASET statement ends the data set.
Specify YES when JOB statements appear in the data set.
- NO
- Indicates that a JOB statement ends the data set. NO is the
default if the J parameter is omitted, unless MODE=C is specified.
- CLASS=NO
- CLASS=MSGCLASS
- CLASS=class
- Identifies the output class JES3 is to use for the data set.
- NO
- Indicates that the system is to assign an output class. If you
omit the CLASS parameter, the default is NO.
- MSGCLASS
- Requests the output class in the MSGCLASS parameter on the JOB
statement.
- class
- Specifies the output class.
|