KFWITM393E User ID or
password is invalid.
- OR -
KFWITM215E: Unable to process
logon request
|
Start Manage Tivoli Monitoring Services and
verify that the Tivoli Enterprise
Portal server is started.
Ensure that the user ID and password are correct when you log
on to the Tivoli Enterprise
Portal.
Use the sysadmin user ID and password.
Determine whether the sysadmin account password
is expired. If so, update the password and corresponding services
by following the steps in Resetting passwords for Tivoli Monitoring for Tivoli Storage Manager.
Verify that the sysadmin account is not locked.
The account is an operating system account.
|
KFWITM010I: Tivoli Enterprise
Portal Server not ready.
- OR -
KFWITM402E: Communication with the
Tivoli Enterprise Server could not
be established.
|
Verify that the Tivoli Enterprise
Portal server is started.
Restart the Tivoli Enterprise
Portal server.
The Portal server initialization can take up to 20 minutes.
Wait 20 minutes and log on again.
You can review the trace log for more information. Start Manage
Tivoli Monitoring Services, right-click the Tivoli Enterprise
Portal server, and
click .
|
KFWITM392E: Internal error
occurred during logon.
|
Start the DB2® instance.
If it is already started, restart it. From a DB2 command window, issue the db2stop and db2start commands
to stop and start the DB2 instance.
|
The portal server cannot initialize
because of a DB2 shutdown.
- OR -
KFWITM009I: The Tivoli Enterprise
Portal Server is still being
initialized and is not ready for
communications.
|
Start the DB2 instance
and wait a few minutes for it to finish initializing.
If you receive message KFWITM009I, you can
look at the most recent trace log to verify that the portal server
is initialized. Search for the text string Waiting for requests.
Startup completed.
To view the trace log, start Manage Tivoli Monitoring
Services, right-click the Tivoli Enterprise
Portal server, and
click .
|
KFWITM008W The Tivoli Enterprise
Portal Server has lost contact
with the Tivoli Enterprise
Monitoring Server.
|
Start Manage Tivoli Monitoring
Services and verify that the Tivoli Enterprise
Monitoring server is started.
|
The following error is displayed:Application Blocked by Security
Settings.
The Java security settings have
prevented this application from
running. You may change this
behavior in the Java Control Panel.
|
The conditions can be relaxed by moving the security slider in the Java™ Control Panel to Medium (from the default of High).
For more information about this problem, see Technote 1659560 (http://www.ibm.com/support/docview.wss?uid=swg21659560).
|