The Operator Panel

With the Operator Panel, you can monitor, configure, and operate library functions from the library front panel.

Figure 1. Operator Panel components

Operator Panel components


Operator Panel components

Table 1. Operator Panel component descriptions
Number Component Description
1 LCD display 16-character LCD graphic display
2 Plus key (+)Up key (Δ) Button that is used to navigate upward (↑) through the menu items.
3 Minus key (-)Down key (∇) Button that is used to navigate downward (↓) through the menu items.
4 Cancel key (X) Button that is used to cancel a user action and return to the last menu item.
5 Enter key Button that is used to display a submenu or to select a user action.
6 Ready/Activity LED Green LED lit when the unit is powered ON and functional. The LED flashes when there is any library activity or the library is offline.
7 Clean Drive LED Amber LED lit when the drive needs cleaning. The LED turns OFF after the drive is cleaned successfully.
8 Attention LED Amber LED lit when a cartridge is bad/marginal, or invalid. The LED turns OFF when all marginal and invalid cartridges are removed from the library. The LED turns on if Autoclean is enabled and no cleaning cartridge is in a cleaning position. The LED might also be lit when there is a power supply problem.
9 Error LED Amber LED lit when there is an unrecoverable library or drive failure. The corresponding error message is displayed on the LCD screen and the LED remains ON until the error state is resolved.
All LEDs are updated during power ON and reset sequences. At power ON or software reset, all LEDs turn on as soon as POST allows. For more information, see Table 3.
The Operator Panel operates in two basic modes:
  • User Interaction mode - Mode that is employed when a user is pushing keys on the Operator Panel. User Interaction mode continues until 3 minutes after a user stops pushing keys, or the requested accessor action stops, whichever is longer.
  • System Driven mode - Normal mode of operation where the Operator Panel displays status in response to commands issued from the drive's internal interface.
Note: Any operational conflict between commands that are received over the host interface or the Web User Interface and those commands that are entered by way of the Operator Panel are avoided with a reservation mechanism on a first-come, first-served basis. Operator Panel commands are canceled by an Operator Panel logout or timeout.

For information on logging in to the Operator Panel, see Logging in to the Operator Panel.

Input modes

There are several ways to enter values in the different menu items. These values are selectable predefined values, toggle values, and numerical values like network addresses.

Selecting predefined values/ toggling states

  1. To set the predefined value/ toggling state, press Enter to select the menu item.
  2. With the Plus and Minus keys, select the predefined value/toggling state for that item.
  3. As soon as the Operator Panel display shows the correct value, press Enter to apply the value/state.

Entering numerical values

Numerical values are needed for network addresses, password entries, and other configuration entries.
  1. After you navigate to the menu item, the current value is displayed and the cursor highlights the first digit of the value that can be changed.
  2. For each digit to be changed in the value, follow the steps below:
    1. Use the Plus and Minus keys to increment or decrement the digit.
    2. Press Enter to highlight the next editable digit.
  3. Press Enter at the last digit to apply the complete entry. Press Cancel to cancel the whole edit process and maintain the original value.
Table 2 shows the top-level menu tree structure of the Operator Panel on the front of the library.
Table 2. Operator Panel menu tree

Operator Panel menu tree

Unlock I/O Station Unlock Magazine Commands Configuration1 View Current Information Service Logout


Move Cartridge
Unload
Clean Drive
Inventory
Move to Ship Position
Reboot Drive
Reboot Library
Change Library State


Configure Library
Configure Auto Cleaning
Configure Network Settings
Configure Op Panel Settings
Configure Web GUI Settings
View Settings
Set Default

Setting Information Slot Information


View Error Status  
Diagnostics
View Firmware Revision
Telnet Service Port2

  1. In the Configuration menu, the current configuration setting is indicated by an asterisk on the Operator Panel screen.
  2. For use by technical support personnel only.

The Operator Panel provides a subset of menu items that are compared to the full capability of the Web User Interface. For the operations that are available on the Operator Panel, see Locating management functions.

Front panel Indicators

LEDs on the front panel of the library provide a visual indication about the status of certain library components. The library also displays an appropriate message on the LCD screen to help identify the reason of failure.

Table 3. Front Panel Indicators

Front Panel Indicators

Library Condition Ready/Activity LED Cleaning LED Attention LED Error LED Message on the LCD screen
POST (Power ON Self Test) Flashes 2 times every 3 seconds OFF OFF OFF INITIALIZING... INVENTORY...
Library is online and ready to receive a command ON OFF OFF OFF READY
Magazine open Flashes 2 times every 3 seconds OFF OFF OFF PLEASE INSERT MAGAZINE
Magazine unlocked Flashes 2 times every 3 seconds OFF OFF OFF MAGAZINE UNLOCKED
I/O Station open Flashes 2 times every 3 seconds OFF OFF OFF PLEASE CLOSE I/O STATION
I/O Station unlocked Flashes 2 times every 3 seconds OFF OFF OFF N/A
Library firmware is being updated Flashes 2 times every 3 seconds OFF OFF OFF LOADER FIRMWARE UPDATING!
Drive firmware is being updated Flashes 2 times every 3 seconds OFF OFF OFF DRIVE FIRMWARE UPDATING!
Drive dump is being uploaded to host computer Flashes 2 times every 3 seconds OFF OFF OFF DRIVE DUMP DATA UPLOADING!
Library is offline Flashes 2 times every 3 seconds OFF OFF OFF OFFLINE
Cartridge is being moved Flashes 2 times every 3 seconds OFF OFF OFF READY
Library error occurred ON OFF OFF ON *** CHK ***

CODE: [XXXX]

Drive error occurred ON OFF OFF ON DRIVE FAULT

CODE: [X]

Cartridge error occurred ON OFF ON OFF MEDIA FAULT

CODE: [X]

Cleaning cartridge expired ON OFF ON OFF REPLACE CLEANING MEDIA
Drive requested cleaning ON ON OFF OFF CLEAN DRIVE
Drive is being cleaned ON Flashes 1 time per second OFF OFF CLEANING...

Any error that is detected by the library or drive controller and not recoverable through predetermined firmware algorithms is considered unrecoverable. When an error occurs, an error code is displayed on the Operator Panel display and the error LED is ON. The error code remains on the Operator Panel until a key is pressed, which causes the Operator Panel to return to the Home Screen. Numeric error codes and or text status messages are displayed. See Error codes.