1087 Shutdown temperature threshold exceeded

Explanation

Shutdown temperature threshold exceeded.

User response

Inspect the enclosure and the enclosure environment.
  1. Check environmental temperature.
  2. Ensure that all of the components are installed or that there are fillers in each bay.
  3. Check that all of the fans are installed and operating properly.
  4. Check for any obstructions to airflow, proper clearance for fresh inlet air, and exhaust air.
  5. Handle any specific obstructed airflow errors that are related to the drive, the battery, and the power supply unit.
  6. Bring the system back online. If the system performed a hard shutdown, the power must be removed and reapplied.

Possible Cause-FRUs or other:

Node (2%)

Battery (1%)

Power supply unit (1%)

Drive (1%)

Other:

Environment (95%)