7042-CR9 Hardware Management Console specifications

Hardware specifications for model 7042-CR9 provide detailed information for your Hardware Management Console (HMC), including dimensions, electrical, power, temperature, environmental specifications, and noise emissions.

The HMC controls managed systems, including the management of logical partitions and the use of capacity on demand. Using service applications, the HMC communicates with managed systems to detect, consolidate, and send information to IBM® for analysis. The HMC provides service technicians with diagnostic information for systems that can operate in a multiple-partitioned environment.

Use the following specifications to plan for your HMC.

Table 1. Dimensions
Width Depth Height Weight
429 mm (16.9 in.) 734 mm (28.9 in.) 43.0 mm (1.7 in.) 15.9 kg (35 lb)
Table 2. Electrical 1
Electrical characteristics Properties
Minimum measured power 135 W
Maximum measured power 183 W
Minimum kVA 0.14
Maximum kVA 0.191
Minimum thermal output 460.62 BTU/hr
Maximum thermal output 624.4 BTU/hr
Input voltage (low range) 100 - 127 V ac
Input voltage (high range) 200 - 240 V ac
Frequency 50 or 60 Hz
  1. Power consumption and heat output vary depending on the number and type of optional features that are installed and the power-management optional features that are in use.
Table 3. Environmental requirements
Environment Allowable operating Nonoperating (system off) Nonoperating (storage) Nonoperating (shipping)
ASHRAE class A3      
Airflow direction Front-to-back      
Temperature

5°C - 40°C (41°F - 104°F) at 0 - 950 m (0 - 3117 ft)

Decrease maximum system temperature by 1°C for every 175 m (574 ft) above 950 m (3117 ft).

5°C - 28°C (41°F - 82°F) at 3050 m (10000 ft)

5°C - 45°C (41°F - 113°F) 1°C - 60°C (33.8°F - 140.0°F) -40°C to 60°C (-40°F to 140°F)
Humidity range

Non-condensing: -12.0°C (10.4°F) dew point

Relative humidity (RH): 8% - 85%

8% - 85% RH 5% to 80% RH 5% - 100% RH
Maximum dew point 24°C (75°F) 27°C (80.6°F)  29°C (84.2°F) 29°C (84.2°F)
Maximum altitude 3050 m (10000 ft) 3050 m (10000 ft) 3050 m (10000 ft) 10700 m (35105 ft)
Table 4. Noise emissions (Maximum configuration)1
Acoustical characteristics Idling Operating
LWAd 6.1 bels 6.1 bels
  1. The noise emission level that is stated is the declared (upper limit) sound power level, in bels, for a random sample of servers. All measurements are made in accordance with ISO 7779 and reported in conformance with ISO 9296.



Last updated: Tue, February 02, 2021