PCIe adapter placement rules and slot priorities for the 8408-44E or 8408-E8E
Find information about the placement rules and slot priorities for the Peripheral Component Interconnect (PCI) Express (PCIe) adapters that are supported for the 8408-44E or 8408-E8E.
PCIe slot descriptions for the 8408-44E and 8408-E8E
The 8408-44E and 8408-E8E systems provide PCIe generation 3 slots. Table 1 provides information about the PCIe slots in the 8408-44E and 8408-E8E system. The PCIe slots are enabled to support the PCIe3 cable adapter (FC EJ08) that is used to attach the EMX0 PCIe Gen3 I/O expansion drawer.
Slot | Adapter size | Slot availability | ||
---|---|---|---|---|
8408-44E and 8408-E8E (2 processors) |
8408-44E and 8408-E8E (3 processors) |
8408-44E and 8408-E8E (4 processors) |
||
PCIe3 x16 | Full-height, half-length | 4 slots (P1-C8, P1-C9, P1-C10, and P1-C12) | 6 slots (P1-C3, P1-C4, P1-C8, P1-C9, P1-C10, and P1-C12) | 8 slots (P1-C1, P1-C2, P1-C3, P1-C4, P1-C8, P1-C9, P1-C10, and P1-C12) |
PCIe3 x8 | Full-height, half-length | 3 slots (P1-C6, P1-C7, and P1-C11) | 3 slots (P1-C6, P1-C7, and P1-C11) | 3 slots (P1-C6, P1-C7, and P1-C11) |
One PCIe generation 3 (PCIe3) switch in the system backplane provides PCIe3 busses for internal PCIe slots and the embedded PCIe USB host controller.
Features provided | PCIe3 Switch |
---|---|
Lanes and ports | 32-lane, 8-ports PCIe Gen3 |
Lane and polarity reversal | Supported |
All ports support concurrent maintenance through I2C bus | Yes |
End-to-end cyclic redundancy check (CRC) and Poison bit error checking | Supported |
Data path parity | Supported |
Memory error correction | Supported |
Advanced error reporting | Supported |
Aggregate full duplex bandwidth | 512 GT/s |
Designate any port as the Upstream port | Yes |
27x27 mm, 676-pin FCBGA package | Yes |
Power consumption |
|
Figure 1 shows the rear view of the system with the location codes for the PCIe adapter slots.
Table 3 lists the PCIe adapter slot locations and details for the 8408-44E and 8408-E8E systems.
Slot | Location code | Description | PHB | Adapter size | Slot capabilities | Slot availability | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
CAPI | SR-IOV | Dynamic direct memory access (DMA) window | I/O adapter enlarged capacity assign order4 | 8408-44E and 8408-E8E (2 processors) |
8408-44E and 8408-E8E (3 processors) |
8408-44E and 8408-E8E (4 processors) |
|||||
Slot 1 | P1-C11 | PCIe3 x16 | Processor Module 4, Chip-0, PHB0 | Full-height, half-length | Yes | Yes | Yes | 5 | No | No | Yes |
Slot 2 | P1-C21,3 | PCIe3 x16 | Processor Module 4, Chip-1, PHB0 | Full-height, half-length | Yes | Yes | Yes | Default | No | No | Yes |
Slot 3 | P1-C31 | PCIe3 x16 | Processor Module 3, Chip-0, PHB0 | Full-height, half-length | Yes | Yes | Yes | 6 | No | Yes | Yes |
Slot 4 | P1-C41,3 | PCIe3 x16 | Processor Module 3, Chip-1, PHB0 | Full-height, half-length | Yes | Yes | Yes | Default | No | Yes | Yes |
Slot 5 | P1-C62, 5 | PCIe3 x8 | PEX8732 Switch, S0P1 | Full-height, half-length | No | Yes | Yes | 10 | Yes | Yes | Yes |
Slot 6 | P1-C72, 5 | PCIe3 x8 | PEX8732 Switch, S1P8 | Full-height, half-length | No | Yes | Yes | 11 | Yes | Yes | Yes |
Slot 7 | P1-C81,3 | PCIe3 x16 | Processor Module 2, Chip-0, PHB0 | Full-height, half-length | Yes | Yes | Yes | 7 | Yes | Yes | Yes |
Slot 8 | P1-C91 | PCIe3 x16 | Processor Module 2, Chip-1, PHB0 | Full-height, half-length | Yes | Yes | Yes | Default | Yes | Yes | Yes |
Slot 9 | P1-C101,3 | PCIe3 x16 | Processor Module 1, Chip-0, PHB0 | Full-height, half-length | Yes | Yes | Yes | 8 | Yes | Yes | Yes |
Slot 10 | P1-C111, 5 | PCIe3 x8 | Processor Module 1, Chip-1, PHB1 | Full-height, half-length | No | Yes | Yes | 9 | Dedicated slot for the LAN adapter | ||
Slot 11 | P1-C121 | PCIe3 x16 | Processor Module 1, Chip-1, PHB0 | Full-height, half-length | Yes | Yes | Yes | Default | Yes | Yes | Yes |
1Slot is a direct slot from the Processor Module and is a high-performance slot. The connectors in these slots are differently colored than the slots from the PCIe3 switch. 2Slot connected by the PCIe3 switch. 3Slot supports up to 75W adapters. 4Assigned PCIe slot order when the I/O Adapter Enlarged Capacity option is enabled. For example, if the option was enabled with a value of 5, five slots (P1-C2, P1-C4, P1-C9, P1-C12, and P1-C1) are enabled with the I/O enlarged capacity. If the option was enabled with a value of 6, then six slots (P1-C2, P1-C4, P1-C9, P1-C12, P1-C1, and P1-C3) are enabled with the I/O enlarged capacity, and so on. 5For platforms with less than 64GB of total system memory, SR-IOV should not be
configured in these slots as performance may be severely impacted.
Note: Enabling the I/O Adapter
Enlarged Capacity option will only affect Linux partitions.
If your system does not have Linux partitions, the I/O
Adapter Enlarged Capacity setting should be disabled.
|
PCIe adapters placement rules
- FCs 5899, EN0W, EN0S, EN0U, EN0H, EN0K, EN0M, EN15, and EN17 are the only adapters that can be installed in slot P1-C11 by IBM® Manufacturing in order to ensure proper system manufacture and testing.
- Slots P1-C1, P1-C2, P1-C3, P1-C4, P1-C8, P1-C9, P1-C10, and P1-C12 are x16 slots with busses direct from the Processor Modules and can be used to install high-performance PCIe adapters.
- All PCIe x16 slots can be used for the PCIe3 Optical Cable Adapter (FC EJ08).
- Slots P1-C1, P1-C2, P1-C3, P1-C4, P1-C8, P1-C9, P1-C10, and P1-C12 are Coherent Accelerator Processor Interface (CAPI) capable.
- Slots P1-C6 and P1-C7 are x8 slots behind the PCIe3 Switch that can be used to install lower-performance PCIe adapters.
- All slots support SR-IOV capable adapters.
Verify whether the adapter is supported for your system. For details about the supported adapters, see PCI adapter information by feature type for the 8408-44E and 8408-E8E.
The 8408-44E and 8408-E8E systems can have two, three, or four system processor modules.
Feature code | Description | 8408-E8E (2 processors) |
8408-E8E (3 processors) |
8408-E8E (4 processors) |
8408-44E (2 processors) |
8408-44E (3 processors) |
8408-44E (4 processors) |
||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Slot priorities | Maximum number of adapters supported | Slot priorities | Maximum number of adapters supported | Slot priorities | Maximum number of adapters supported | Slot priorities | Maximum number of adapters supported | Slot priorities | Maximum number of adapters supported | Slot priorities | Maximum number of adapters supported | ||
5285 | PCIe2
2-port 4X InfiniBand QDR Adapter (FC 5285; CCIN 58E2); Adapter FRU
number: 74Y2987
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
5287 | PCIe2
2-port 10 GbE SR Adapter (FC 5287; CCIN 5287); Adapter FRU number:
74Y3457
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
5708 | PCIe
10 Gb FCoE 2-port Adapter (FC 5708; CCIN 2B3B)
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
5717 | 4-port
10/100/1000 Base-TX PCI Express Adapter
(FC 5717; CCIN 5217); Adapter FRU number: 46Y3512
|
5, 6, 9, 7, 11, 8 | 6 | 5, 6, 9, 7, 4, 11, 8, 3 | 8 | 5, 6, 9, 7, 4, 2, 11, 8, 3, 1 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
5729 | PCIe2
FH 4-port 8 Gb74Y3467 Fibre Channel Adapter (FC 5729; CCIN 5729);
Adapter FRU number: 74Y3467
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
5735 | 8 Gb PCI Express Dual-port Fibre Channel
Adapter (FC 5735; CCIN 577D); Adapter FRU number: 10N9824
|
5, 6, 9, 7, 11, 8 | 6 | 5, 6, 9, 7, 4, 11, 8, 3 | 8 | 5, 6, 9, 7, 4, 2, 11, 8, 3, 1 | 10 | 5, 6, 8, 11, 7, 9 | 6 | 5, 6, 8, 3, 11, 7, 4, 9 | 8 | 5, 6, 8, 3, 1, 11, 7, 4, 2, 9 | 10 |
5744 | PCIe2
2x10 GbE SR 2x1 GbE UTP Adapter (FC 5744; CCIN 2B44); Adapter FRU
number: 74Y1987
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
5748 | POWER® GXT145 PCI Express Graphics Accelerator (FC
5748; CCIN 5748); Adapter FRU number: 10N7756
|
5, 9, 7, 11, 8 | 5 | 5, 9, 7, 4, 11, 8, 3 | 7 | 5, 9, 7, 4, 2, 11, 8, 3, 1 | 9 | 5, 8, 11, 7, 9 | 5 | 5, 8, 3, 11, 7, 4, 9 | 7 | 5, 8, 3, 1, 11, 7, 4, 2, 9 | 9 |
5767 | 2-port
10/100/1000 Base-TX Ethernet PCI Express Adapter (FC 5767;
CCIN 5767); Adapter FRU number: 46K6601
|
5, 6, 9, 7, 11, 8 | 6 | 5, 6, 9, 7, 4, 11, 8, 3 | 8 | 5, 6, 9, 7, 4, 2, 11, 8, 3, 1 | 10 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
5769 | 10 Gb
Ethernet-SR PCI Express Adapter
(FC 5769; CCIN 5769); Adapter FRU number: 46K7897
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
5785 | 4-port Async EIA-232
PCIe Adapter (FC 5785; CCIN 57D2); Adapter FRU number: 46K6734
|
5, 9, 7, 11, 8 | 5 | 5, 9, 7, 4, 11, 8, 3 | 7 | 5, 9, 7, 4, 2, 11, 8, 3, 1 | 9 | 5, 8, 11, 7, 9 | 5 | 5, 8, 3, 11, 7, 4, 9 | 7 | 5, 8, 3, 1, 11, 7, 4, 2, 9 | 9 |
5899 | PCIe2
4-port 1 GbE Adapter (FC 5899; CCIN 576F); Adapter FRU number: 74Y4064
OS support:
|
10, 5, 6, 8, 11, 7, 9 | 7 | 10, 5, 6, 8, 3, 11, 7, 4, 9 | 9 | 10, 5, 6, 8, 3, 1, 11, 7, 4, 2, 9 | 11 | 11, 5, 6, 8, 11, 7, 9 | 7 | 11, 5, 6, 8, 3, 11, 7, 4, 9 | 9 | 11, 5, 6, 8, 3, 1, 11, 7, 4, 2, 9 | 11 |
5901 | PCIe
Dual - x4 SAS Adapter (FC 5901; CCIN 57B3); Adapter FRU number: 44V4852
|
5, 6, 9, 7, 11, 8 | 6 | 5, 6, 9, 7, 4, 11, 8, 3 | 8 | 5, 6, 9, 7, 4, 2, 11, 8, 3, 1 | 10 | 5, 6, 8, 11, 7, 9 | 6 | 5, 6, 8, 3, 11, 7, 4, 9 | 8 | 5, 6, 8, 3, 1, 11, 7, 4, 2, 9 | 10 |
EC2N | PCIe3 2-port 10 GbE
NIC and RoCE SR adapter (FC EC2N; CCIN 57BE); Adapter FRU
number: 00RX875
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 10, 8, 11, 7, 9, 5, 6 | 7 | 10, 8, 3, 11, 7, 4, 9, 5, 6 | 9 | 11, 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 11 |
EC30 | PCIe2 FH 2-port 10 GbE
RoCE SR adapter (FC EC30; CCIN EC29); Adapter FRU number: 00E1601
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
EC38 | PCIe3 2-port 10 GbE
NIC and RoCE SFP+ Copper Adapter (FC EC38; CCIN 57BC); Adapter
FRU number: 00RX859
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 10, 8, 11, 7, 9, 5, 6 | 7 | 10, 8, 3, 11, 7, 4, 9, 5, 6 | 9 | 11, 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 11 |
EC3B | PCIe3 2-Port 40 GbE NIC RoCE QSFP+ Adapter (FC
EC3B; CCIN 57BD); Adapter FRU number: 00FW105
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
EC3F | PCIe3 2-port 100 Gb EDR IB Adapter x16 (FC
EC3E and EC3F; CCIN 2CEA); Adapter FRU number:
00WT075
|
9, 7, 11, 8 | 4 | 9, 7, 4, 11, 8, 3 | 6 | 9, 7, 4, 2, 11, 8, 3, 1 | 8 | 8, 11, 7, 9 | 3 | 8, 3, 11, 7, 4, 9 | 3 | 8, 3, 1, 11, 7, 4, 2, 9 | 3 |
EC3M | PCIe3
2-port 100 GbE (NIC and RoCE) QSFP28 Adapter (FC EC3L and EC3M; CCIN 2CEC); Adapter FRU
number: 00WT078
|
9, 7, 11, 8 | 4 | 9, 7, 4, 11, 8, 3 | 6 | 9, 7, 4, 2, 11, 8, 3, 1 | 8 | 8, 11, 7, 9 | 3 | 8, 3, 11, 7, 4, 9 | 3 | 8, 3, 1, 11, 7, 4, 2, 9 | 3 |
EC3U | PCIe3 1-port 100 Gb EDR
Infiniband Adapter x16 (FC EC3U; CCIN 2CEB) Adapter FRU number: 00WT013
|
9, 7, 11, 8 | 4 | 9, 7, 4, 11, 8, 3 | 6 | 9, 7, 4, 2, 11, 8, 3, 1 | 8 | 8, 11, 7, 9 | 3 | 8, 3, 11, 7, 4, 9 | 3 | 8, 3, 1, 11, 7, 4, 2, 9 | 3 |
EC42 | PCIe2 3D Graphics Adapter
x1 (FC EC42); Adapter FRU number: 00E3980
|
5, 6, 9, 7, 11, 8 | 6 | 5, 6, 9, 7, 4, 11, 8, 3 | 8 | 5, 6, 9, 7, 4, 2, 11, 8, 3, 1 | 10 | 5, 6, 8, 11, 7, 9 | 6 | 5, 6, 8, 3, 11, 7, 4, 9 | 8 | 5, 6, 8, 3, 1, 11, 7, 4, 2, 9 | 10 |
EC46 | PCIe2
4-port USB 3.0 Adapter (FC EC46; CCIN 58F9); Adapter FRU number: 00E2932
|
Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EC551 | PCIe3 1.6 TB NVMe Flash Adapter (FC EC54 and EC55; CCIN
58CB); Adapter FRU number: 00MH991
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
EC571 | PCIe3 3.2 TB NVMe Flash Adapter
(FC EC56 and EC57; CCIN 58CC); Adapter FRU number: 00MH993
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
EJ08 | PCIe3 cable adapter that
is used to connect your system to the EMX0 PCIe3 expansion drawer (FC EJ08; CCIN
2CE2); Adapter FRU number: 041T9901
|
9, 7, 11, 8 | 4 | 9, 7, 3, 11, 8, 4 | 6 | 9, 7, 3, 1, 11, 8, 4, 2 | 8 | 8, 11, 7, 9 | 4 | 8, 3, 11, 7, 4, 9 | 6 | 8, 3, 1, 11, 7, 4, 2, 9 | 8 |
EJ0J | PCIe3 RAID SAS quad-port
6 Gb Adapter (FC EJ0J; CCIN 57B4); Adapter FRU number: 000FX846
|
9, 7, 8, 5, 6 | 5 | 9, 7, 4, 8, 3, 5, 6 | 7 | 9, 7, 4, 2, 8, 3, 1, 5, 6 | 9 | 9, 8, 10, 6, 7 | 5 | 9, 3, 8, 4, 10, 6, 7 | 7 | 9, 3, 1, 8, 4, 2, 10, 6, 7 | 9 |
EJ0L | PCIe3 12 GB Cache RAID
SAS quad-port 6 Gb Adapter (FC EJ0L; CCIN 57CE); Adapter
FRU number: 00FX840
|
9, 7 | 2 | 9, 7, 4 | 3 | 9, 7, 4, 2 | 4 | 8, 11 | 2 | 8, 3, 11 | 3 | 8, 3, 1, 11 | 4 |
EJ10 | PCIe3 4 x8 SAS Port
Adapter (FC EJ10; CCIN 57B4); Adapter FRU number: 00RR793 for 8408-44E or 8408-E8E and
00MH959 for all other machine type models
|
9, 7, 8, 5, 6 | 5 | 9, 7, 4, 8, 3, 5, 6 | 7 | 9, 7, 4, 2, 8, 3, 1, 5, 6 | 9 | 9, 8, 10, 6, 7 | 5 | 9, 3, 8, 4, 10, 6, 7 | 7 | 9, 3, 1, 8, 4, 2, 10, 6, 7 | 9 |
EJ14 | PCIe3
12 GB Cache RAID PLUS SAS Adapter Quad-port 6 Gb x8 (FC EJ14; CCIN
57B1); Adapter FRU number 01DH742
|
9, 7 | 2 | 9, 7, 4 | 3 | 9, 7, 4, 2 | 4 | 8, 11 | 2 | 8, 3, 11 | 3 | 8, 3, 1, 11 | 4 |
EJ1P | PCIe1 SAS Tape/DVD Dual-port 3 Gb x8 Adapter (FC EJ1P and
EJ1N; CCIN 57B3); Adapter FRU:44V4852
|
5, 6, 9, 7, 11, 8 | 5 | 5, 6, 9, 7, 4, 11, 8, 3 | 7 | 5, 6, 9, 7, 4, 2, 11, 8, 3, 1 | 9 | 5, 6, 8, 11, 7, 9 | 6 | 5, 6, 8, 3, 11, 7, 4, 9 | 8 | 5, 6, 8, 3, 1, 11, 7, 4, 2, 9 | 8 |
EJ27, EJ28, and EJ29 | PCIe
Cryptographic Coprocessor (FC EJ27, FC EJ28, and FC EJ29; CCIN 476A);
Adapter FRU number: 45D7948
|
5, 6, 9, 7, 11, 8 | 6 | 5, 6, 9, 7, 4, 11, 8, 3 | 8 | 5, 6, 9, 7, 4, 2, 11, 8, 3, 1 | 10 | 5, 6, 8, 11, 7, 9 | 6 | 5, 6, 8, 3, 11, 7, 4, 9 | 8 | 5, 6, 8, 3, 1, 11, 7, 4, 2, 9 | 10 |
EJ32 | 4767-001 Cryptographic Coprocessor (FC EJ32 and EJ33; CCIN
4767)
|
5, 6, 9, 7, 11, 8 | 6 | 5, 6, 9, 7, 4, 11, 8, 3 | 8 | 5, 6, 9, 7, 4, 2, 11, 8, 3, 1 | 10 | 5, 6, 8, 11, 7, 9 | 6 | 5, 6, 8, 3, 11, 7, 4, 9 | 8 | 5, 6, 8, 3, 1, 11, 7, 4, 2, 9 | 10 |
EN0A | PCIe3 16 Gb
2-port Fibre Channel Adapter (FC EN0A; CCIN 577F); Adapter FRU number: 00E3496
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
EN0G | PCIe2 8Gb 2-Port Fibre Channel
Adapter (FC EN0F and EN0G; CCIN 578D); Adapter FRU number: 00WT111
|
11, 9, 8, 7, 6, 5 | 6 | 11, 3, 9, 8, 7, 6, 5, 4 | 8 | 1, 11, 3, 9, 8, 7, 6, 2, 5, 4 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
EN0H | PCIe3
4-port (2x10 Gb FCoE, 2x1 GbE) SFP+ Adapter (FC EN0H; CCIN 2B93); Adapter FRU number: 00E3498
|
10, 9, 7, 11, 8, 5, 6 | 7 | 10, 9, 7, 4, 11, 8, 3, 5, 6 | 9 | 10, 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 11 | 10, 8, 11, 7, 9, 5, 6 | 7 | 10, 8, 3, 11, 7, 4, 9, 5, 6 | 9 | 11, 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 11 |
EN0K | PCIe3 4-port (10 Gb FCoE and 1 GbE) Copper and RJ45 Adapter
(FC EN0K; CCIN 2CC1); Adapter FRU number: 00E8140
|
10, 9, 7, 11, 8, 5, 6 | 7 | 10, 9, 7, 4, 11, 8, 3, 5, 6 | 9 | 10, 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 11 | 10, 8, 11, 7, 9, 5, 6 | 7 | 10, 8, 3, 11, 7, 4, 9, 5, 6 | 9 | 11, 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 11 |
EN0M | PCIe3 4-port (10 Gb FCoE and 1 GbE) LR and RJ45 Adapter (FC
EN0M; CCIN 2CC0); Adapter FRU number: 00E8144
|
9, 7, 11, 8, 5, 6 | 6 | 9, 7, 4, 11, 8, 3, 5, 6 | 8 | 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
EN0S | PCIe2 4-port (10 Gb + 1 GbE)
SR+RJ45 Adapter (FC EN0S; CCIN 2CC3); Adapter FRU number: 00E2715;
Part number (Full-height tailstock): 00E2863; Part number (Low-profile
tailstock): 00E2720
|
10, 9, 7, 11, 8, 5, 6 | 7 | 10, 9, 7, 4, 11, 8, 3, 5, 6 | 9 | 10, 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 11 | 10, 8, 11, 7, 9, 5, 6 | 7 | 10, 8, 3, 11, 7, 4, 9, 5, 6 | 9 | 11, 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 11 |
EN0U | PCIe2
4-port (10 Gb + 1 GbE) Copper SFP+RJ45 Adapter (FC EN0U; CCIN 2CC3);
Adapter FRU number: 00E2715; low-profile tailstock: 00E2720
|
10, 9, 7, 11, 8, 5, 6 | 7 | 10, 9, 7, 4, 11, 8, 3, 5, 6 | 9 | 10, 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 11 | 10, 8, 11, 7, 9, 5, 6 | 7 | 10, 8, 3, 11, 7, 4, 9, 5, 6 | 9 | 11, 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 11 |
EN0W | PCIe2
2-port 10 GbE BaseT RJ45 Adapter (FC EN0W; CCIN 2CC4); Adapter FRU number: 00E2714
|
10, 9, 7, 11, 8, 5, 6 | 7 | 10, 9, 7, 4, 11, 8, 3, 5, 6 | 9 | 10, 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 11 | 10, 8, 11, 7, 9, 5, 6 | 7 | 10, 8, 3, 11, 7, 4, 9, 5, 6 | 9 | 11, 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 11 |
EN12 | PCIe2 FH 4-port 8 Gb Fibre Channel Adapter (FC
EN12; CCIN EN0Y); Adapter FRU number 00WT107
|
11, 9, 8, 7, 6, 5 | 6 | 11, 3, 9, 8, 7, 6, 5, 4 | 8 | 1, 11, 3, 9, 8, 7, 6, 2, 5, 4 | 10 | 8, 11, 7, 9, 5, 6 | 6 | 8, 3, 11, 7, 4, 9, 5, 6 | 8 | 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 10 |
EN15 | PCIe3
4-port 10 GbE SR Adapter (FC EN15; CCIN 2CE3); Adapter FRU number:
00ND466; full-height tailstock: 00ND462
|
10, 9, 7, 11, 8, 5, 6 | 7 | 10, 9, 7, 4, 11, 8, 3, 5, 6 | 9 | 10, 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 11 | 10, 8, 11, 7, 9, 5, 6 | 7 | 10, 8, 3, 11, 7, 4, 9, 5, 6 | 9 | 11, 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 11 |
EN17 | PCIe3
4-port 10 GbE SFP+ Copper Adapter (FC EN17, CCIN 2CE4); Adapter FRU
number: 00ND463; full-height tailstock part number: 00ND465
|
10, 9, 7, 11, 8, 5, 6 | 7 | 10, 9, 7, 4, 11, 8, 3, 5, 6 | 9 | 10, 9, 7, 4, 2, 11, 8, 3, 1, 5, 6 | 11 | 10, 8, 11, 7, 9, 5, 6 | 7 | 10, 8, 3, 11, 7, 4, 9, 5, 6 | 9 | 11, 8, 3, 1, 11, 7, 4, 2, 9, 5, 6 | 11 |
EN27 | PCIe
2-port Async EIA-232 Adapter (FC EN27; CCIN 57D4); Adapter FRU number:
000ND487
|
5, 6, 9, 7, 11, 8 | 6 | 5, 6, 9, 7, 4, 11, 8, 3 | 8 | 5, 6, 9, 7, 4, 2, 11, 8, 3, 1 | 10 | 5, 6, 8, 11, 7, 9 | 6 | 5, 6, 8, 3, 11, 7, 4, 9 | 8 | 5, 6, 8, 3, 1, 11, 7, 4, 2, 9 | 10 |
1FC EC55 and EC57 are currently only supported on 8408-44E. |