PCI adapter placement rules and slot priorities for the 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, or 8205-E6D
Some adapters must be placed in specific peripheral component interconnect (PCI), peripheral component interconnect-X (PCI-X), or PCI Express (PCIe) slots to function correctly or to perform optimally. Learn how to determine the slots in the server or expansion units where you can install the PCI adapters.
PCI slot descriptions for the 8202-E4B and 8205-E6B
Figure 1, Figure 2 shows the rear view of the server with the location codes for the PCI adapter slots. Figure 3 shows the four PCIe x8 low-profile slots as an optional PCIe expansion feature. The PCIe expansion feature is installed at the GX++ slot 1. Each PCIe is a separate PCI host bridge (PHB).
The Table 1 lists the adapter slot locations and details for the 8202-E4B and 8205-E6B.
Slot | Location code | Description | PHB | Adapter size |
---|---|---|---|---|
Slot 1 | P1-C4 | PCIe x8 | PCIe PHB0 module A | Short |
Slot 2 | P1-C5 | PCIe x8 | PCIe PHB1 module A | Short |
Slot 3 | P1-C6 | PCIe x8 | PCIe PHB2 module A | Short |
Slot 4 | P1-C7 | PCIe x8 | PCIe PHB3 module A | Short |
Slot 5 | P1-C1-C1 | PCIe x8 low-profile | PCIe PHB0 module B | Low-profile |
Slot 6 | P1-C1-C2 | PCIe x8 low-profile | PCIe PHB1 module B | Low-profile |
Slot 7 | P1-C1-C3 | PCIe x8 low-profile | PCIe PHB3 module B | Low-profile |
Slot 8 | P1-C1-C4 | PCIe x8 low-profile | PCIe PHB4 module B | Low-profile |
|
PCI slot descriptions for 8202-E4C, 8202-E4D, 8205-E6C, and 8205-E6D
Figure 4 shows the PCI slots and their location codes for 8202-E4C, 8202-E4D, 8205-E6C, and 8205-E6D systems. The 8202-E4C, 8202-E4D, 8205-E6C, and 8205-E6D systems have five PCIe x8 G2 full-height half-length slots and one PCIe x4 full-height half-length slot. All slots support enhanced error handling (EEH), but are not hot pluggable. PCIe slots 1 and 4 have an x16 connector, and the other slots have x8 connector. Table 2 lists the adapter slot locations and details for the 8202-E4C, 8202-E4D, 8205-E6C, and 8205-E6D.
Slot | Location code | Description | PHB | Adapter size | Direct memory access (DMA) capable |
---|---|---|---|---|---|
Slot 1 | P1-C2 | PCIe x8 generation 2 | PCIe-PHB5 | Full-height Half-length | 64-bit |
Slot 2 | P1-C3 | PCIe x8 generation 2 | PCIe-PHB4 | Full-height Half-length | 32-bit |
Slot 3 | P1-C4 | PCIe x8 generation 2 | PCIe-PHB3 | Full-height Half-length | 32-bit |
Slot 4 | P1-C5 | PCIe x8 generation 2 | PCIe-PHB2 | Full-height Half-length | 64-bit |
Slot 5 | P1-C6 | PCIe x8 generation 2 | PCIe-PHB1 | Full-height Half-length | 32-bit |
Slot 6 | P1-C7 | PCIe x4 generation 2 | PCIe-PHB0 | Full-height Half-length | 32-bit |
Slot 7 | P1-C1-C1 | PCIe x8 generation 2 | PCIe PHB0 module B | Low-profile | 32-bit |
Slot 8 | P1-C1-C2 | PCIe x8 generation 2 | PCIe PHB1 module B | Low-profile | 32-bit |
Slot 9 | P1-C1-C3 | PCIe x8 generation 2 | PCIe PHB3 module B | Low-profile | 32-bit |
Slot 10 | P1-C1-C4 | PCIe x8 generation 2 | PCIe PHB4 module B | Low-profile | 32-bit |
|
PCIe expansion units
PCIe expansion units, feature code (FC) 5685, provides connector slots for four low-profile generation-1 or generation-2 PCIe adapters and can be installed in slots C1-C1 to C1-C4. FC 5610 provides connector slots for four low-profile PCIe generation-1 adapters and can be installed in slots C1-C1 to C1-C4. The PCIe generation-2 adapters work best on FC 5685. PCIe expansion unit, FC 5877 and FC 5802 are supported on the system running IBM® AIX®, IBM i, or Linux. The system can be configured to support up to two I/O expansion units per GX adapter.
The expansion units attach to a 4X channel adapter installed in the GX slots available in the system.
- Systems with one processor chip module unit support up to two 5802 or 5877 expansion units. The system has only one GX adapter supported.
- Systems with two processor chip module units support up to four 5802 or 5877 expansion units, that is, two per GX channel adapter.
- If you install feature code 5610 or 5685 in the system, you cannot install the 5615 or EJ04, expansion unit, and any I/O expansion drawers. This results in a total of eight internal slots.
- If you do not install feature code 5610 or 5685 in the system, a total of four internal slots are available and you can install an I/O expansion unit.
- If you install the feature code 5685 in the system, only one 5615 or EJ04 unit can be installed and results in a total of ten internal slots.
- If you do not install feature code 5685 in the system, a total of six internal slots are available.
PCI, PCI-X, and PCIe adapters
Use this information to identify slot placement priorities in the system and the maximum number of adapters that can be installed in the system and attached expansion units. Verify whether the adapter is supported for your system. For details about the supported adapters, see Supported PCI adapters for the 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, or 8205-E6D.
FCs 5767, 5768, and 9055 are the only adapters that can be installed in slot 6 (P1-C7). If a GX adapter is installed in GX++ slot 2 (P1-C8), FCs 5767, 5768, and 9055 must be installed in the other PCIe x8 slot.
Feature code | Description | 8202-E4B and 8205-E6B | 8202-E4C, 8202-E4D, 8205-E6C, and 8205-E6D | ||
---|---|---|---|---|---|
Slot priorities3 | Maximum number of adapters supported | Slot priorities3 | Maximum number of adapters supported | ||
2943 | 8-port Asynchronous EIA-232E/RS-422A
PCI Adapter (FC 2943; CCIN 3-B)
|
All slots have the same priority | 24 and 32 | All slots have the same priority | 24 and 32 |
5723 | 2-port
Asynchronous EIA-232 PCI Adapter (FC 5723; CCIN 5723)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
1905 | 4 Gb Single-port Fibre Channel
PCI-X 2.0 DDR Adapter (FC 1905; CCIN 1910)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
1910 | 4 Gb Dual-port Fibre Channel
PCI-X 2.0 DDR Adapter (FC 1910; CCIN 1910)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
19771 | 2 Gb Fibre Channel PCI-X Adapter
(FC 1977; CCIN 197E)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
57161 | 2 Gb Fibre Channel PCI-X Adapter
(FC 5716; CCIN 280B)
|
All slots have the same priority | All slots have the same priority | ||
57492 | 4 Gb Dual-port Fibre Channel
PCI-X 2.0 DDR Adapter (FC 5749; CCIN 576B)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
5758 | 4 Gb Single-port Fibre Channel
PCI-X 2.0 DDR Adapter (FC 5758; CCIN 1910)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
57592 | 4 Gb Dual-port Fibre Channel
PCI-X 2.0 DDR Adapter (FC 5759; CCIN 5759)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
1980 and 2849 | POWER® GXT135P Graphics Accelerator
with digital support (FC 1980; CCIN 1980)
|
All slots have the same priority | 8 | All slots have the same priority | 8 |
1954 | 4-port 10/100/1000 Base-TX PCI-X
adapter (FC 1954)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
1978 | IBM Gigabit
Ethernet-SX PCI-X Adapter (FC 1978)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
1979 | IBM 10/100/1000
Base-TX Ethernet PCI-X Adapter (FC 1979)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
19831 | 2-port 10/100/1000 Base-TX Ethernet
PCI-X Adapter (FC 1983; CCIN 5706)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
1986 | 1-Gb iSCSI TOE PCI-X Adapter
(FC 1986; CCIN 573B)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
1987 | 1-Gb iSCSI TOE PCI-X Adapter
(FC 1987; CCIN 573C)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
5700 | IBM Gigabit
Ethernet-SX PCI-X Adapter (FC 5700; CCIN 5700)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
5701 | IBM 10/100/1000
Base-TX Ethernet PCI-X Adapter (FC 5701; CCIN 5701)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
57061 | 2-port 10/100/1000 Base-TX Ethernet
PCI-X Adapter (FC 5706; CCIN 5706)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
57131 | 1 Gb-TX iSCSI TOE PCI-X Adapter
(FC 5713; CCIN 573B)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
57141 | 1 Gb iSCSI TOE PCI-X on Optical
Media Adapter (FC 5714; CCIN 573C)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
57211 | 10 Gb Ethernet-SR PCI-X 2.0 DDR
Adapter (FC 5721; CCIN 573A)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
57221 | 10 Gb Ethernet-LR PCI-X 2.0 DDR
Adapter (FC 5722; CCIN 573A)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
5740 | 4-port 10/100/1000 Base-TX PCI-X
adapter (FC 5740; CCIN 1954)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
2738 | 2-port USB PCI Adapter (FC 2738;
CCIN 28EF)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
4764 | PCI-X Cryptographic Coprocessor
(FC 4764; CCIN 4764)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
59002 | PCI-X DDR Dual-x4 3 Gb SAS Adapter
(FC 5900; CCIN 572A)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
59022 | PCI-X DDR Ext Dual-x4 3 Gb SAS
RAID Adapter (FC 5902; CCIN 572B)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
59082 | PCI-X DDR 1.5 GB cache SAS RAID
Adapter (FC 5908; CCIN 572F, 575C)
|
All slots have the same priority | 8 and 16 | All slots have the same priority | 8 and 16 |
59122 | PCI-X DDR Dual-x4 3 Gb SAS Adapter
(FC 5912; CCIN 572A)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
19121 | PCI-X DDR 2.0 Dual Channel Ultra320
SCSI Adapter (FC 1912; CCIN 571A)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
57361 | PCI-X DDR 2.0 Dual Channel Ultra320
SCSI Adapter (FC 5736; CCIN 571A)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
57822 | PCI-X Dual Channel Ultra320 SCSI
RAID Adapter with Auxiliary Write Cache (double-wide) (FC 5782; CCIN
571F and 575B)
|
All slots have the same priority | 8 and 16 | All slots have the same priority | 8 and 16 |
2947 | IBM ARTIC960Hx 4-port Multiprotocol PCI
Adapter (FC 2947)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
6805 | IBM ARTIC960Hx 4-port Multiprotocol PCI
Adapter (FC 2947)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
6808 | PCI Quad Modem IOA (FC 6808;
CCIN 2805)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
6809 | PCI Quad Modem IOA (FC 6809;
CCIN 2805)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
6833 | PCI 2-Line WAN with Modem No
IOP (FC 6833; CCIN 2793)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
6834 | PCI 2-Line WAN with Modem No
IOP CIM (FC 6834; CCIN 2793)
|
All slots have the same priority | 24 and 48 | All slots have the same priority | 24 and 48 |
5277 | 4-port Async EIA-232 PCIe 1X
LP Adapter (FC 5277; CCIN 57D2)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5289 | PCIe 2-port Async EIA-232 PCIe
1X LPC Adapter (FC 5289; CCIN 57D4)
|
1, 3, 2, 4 | 12 | 6, 5, 4, 3, 2, 1 | 12 |
5290 | PCIe LP 2-port Async EIA-232
Adapter (FC 5290; CCIN 57D4)
|
5, 7, 6, 8 | 2 | 7, 9, 8, 10 | 2 |
5785 | 4 Port Async EIA-232 PCIe Adapter
(FC 5785; CCIN 57D2)
|
1, 3, 2, 4 | 24 and 44 | 5, 4, 3, 2, 1 | 25 and 45 |
5273 | 8 Gb PCI Express Dual-port Fibre Channel
Adapter (FC 5273; CCIN 577D)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5276 | 4-Gb PCI Express Dual-port Fibre Channel
Adapter (FC 5276; CCIN 5774)
|
5, 7, 6, 8 | 7, 9, 8, 10 | ||
57291 | PCIe2 FH 4-port 8 Gb Fibre Channel
Adapter (FC 5729; CCIN 5729)
|
Not supported | 5, 4, 3, 2, 1 | 5 | |
5735 | 8 Gb PCI Express Dual-port Fibre Channel
Adapter (FC 5735; CCIN 577D)
|
1, 3, 2, 4 | 24 and 44 | 6, 5, 4, 3, 2, 1 | 25 and 45 |
57731 | 4 Gb PCI Express Single Port Fibre
Channel Adapter (FC 5773; CCIN 5773)
|
1, 3, 2, 4 | 24 and 44 | 6, 5, 4, 3, 2, 1 | 25 and 45 |
57742 | 4 Gb PCI Express Dual-port Fibre Channel
Adapter (FC 5774; CCIN 5774)
|
1, 3, 2, 4 | 24 and 44 | 6, 5, 4, 3, 2, 1 | 25 and 45 |
EN0A | PCIe2 16 Gb 2-port Fibre Channel
Adapter (FC EN0A; CCIN 577F)
|
Not supported | 5, 4, 3, 2, 1 | 5 | |
EN0B | PCIe2 LP 16 Gb 2-port Fibre Channel
Adapter (FC EN0B; CCIN 577F)
|
Not supported | 7, 9, 8, 10 | 4 | |
EN0S |
PCIe2 4-port (10Gb+1GbE) SR+RJ45 Adapter (FC EN0S; CCIN 2CC3)
|
Not supported | 1, 4, 2, 3, 5 | 5 | |
EN0T |
PCIe2 LP 4-port (10Gb+1GbE) SR+RJ45 Adapter (FC EN0T; CCIN 2CC3)
|
Not supported | 7, 8, 9, 102 | 4 | |
EN0U |
PCIe2 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter (FC EN0U; CCIN 2CC3)
|
Not supported | 1, 4, 2, 3, 5 | 5 | |
EN0V |
PCIe2 LP 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter (FC EN0V; CCIN 2CC3)
|
Not supported | 7, 8, 9, 102 | 4 | |
EN0W |
PCIe2 2-port 10 GbE BaseT RJ45 Adapter (FC EN0W; CCIN 2CC4)
|
Not supported | 1, 4, 2, 3, 5 | 5 | |
EN0X |
PCIe2 LP 2-port 10 GbE BaseT RJ45 Adapter (FC EN0X; CCIN 2CC4)
|
Not supported | 7, 8, 9, 102 | 4 | |
EN0Y2 | PCIe2 LP 8Gb 4-port Fibre Channel
Adapter (FC EN0Y; CCIN EN0Y)
|
5, 7, 6, 82 | 4 | 7, 9, 8, 102 | 4 |
EN27 |
PCIe 2-port Async EIA-232 Adapter (FC EN27; CCIN 57D4)
|
1, 3, 2, 4 | 12 | 1, 2, 3, 4, 5 | 12 |
EN28 |
PCIe 2-port Async EIA-232 LP Adapter (FC EN28; CCIN 57D4)
|
5, 7, 6, 8 | 2 | 7, 9, 8, 10 | 2 |
5269 | POWER GXT145 PCI Express Graphics Accelerator
(FC 5269; CCIN 5269)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
EC41 | PCIe2 LP 3D Graphics Adapter
x1 (FC EC41)
|
7, 9, 8, 10 | 4 | ||
EC42 | PCIe2 3D Graphics Adapter x1
(FC EC42)
|
All slots have the same priority (1, 2, 3, 4, 5) | 5 | ||
5748 | POWER GXT145 PCI Express Graphics Accelerator (FC 5748; CCIN 5748)
|
All slots have the same priority (1, 2, 3, 4) | 8 | All slots have the same priority (1, 2, 3, 4, 5) | 8 |
EJ0J | PCIe3 RAID SAS Adapter (FC EJ0J;
CCIN 57B4)
|
Not supported | 5, 4, 3, 2, 1 | 4 | |
EJ0L | PCIe3 12 GB Cache RAID SAS quad-port
6 Gb Adapter (FC EJ0L; CCIN 57CE)
|
Not supported | 5, 4, 3, 2, 1 | 2 | |
EJ0M | PCIe3 LP RAID SAS Adapter (FC
EJ0M; CCIN 57B4)
|
Not supported | 7, 9, 8, 10 | 2 | |
EJ10 | PCIe3 4 x8 SAS Port Adapter
(FC EJ10; CCIN 57B4)
|
Not supported | 5, 4, 3, 2, 1 | 4 | |
EJ11 | PCIe3 LP 4 x8 SAS Port Adapter
(FC EJ11; CCIN 57B4)
|
Not supported | 7, 9, 8, 10 | 4 | |
52602 | PCIe2 LP 4-port 1 GbE Adapter
(FC 5260; CCIN 576F)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5270 | 10 Gb FCoE PCIe Dual-port Adapter
(FC 5270; CCIN 2B3B)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5271 | 4-port 10/100/1000 Base-TX PCI Express Adapter (FC 5271;
CCIN 5717)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5272 | 10 Gb Ethernet-CX4 PCI Express Adapter (FC 5272;
CCIN 5272)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5274 | 2-port Gb Ethernet-SX PCI Express Adapter (FC 5274;
CCIN 5768)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5275 | 10 Gb Ethernet-SR PCI Express Adapter (FC 5275;
CCIN 2B54)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5278 | PCIe Dual-x4 SAS Adapter (FC
5278; CCIN 57B3)
|
Not supported | 7, 9, 8, 10 | 4 | |
5279 | PCIe2 LP 2x10 GbE SFP+ Copper
2x1 GbE UTP Adapter (FC 5279; CCIN 2B52)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5280 | PCIe2 LP 2x10 GbE SR 2x1 GbE
UTP Adapter (FC 5280; CCIN 2B54)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5281 | 1 Gb Ethernet UTP 2-port PCIe
Adapter (FC 5281; CCIN 5767)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
52842 | PCIe2 LP 2-port 10 GbE SR Adapter
(FC 5284; CCIN 5287)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5286 | PCIe2 LP 2-port 10 GbE SFP+ Copper
Adapter (FC 5286; CCIN 5288)
|
5, 7, 6, 8 | 4 | 7, 9, 8, 10 | 4 |
5287 | PCIe2 2-port 10 GbE SR Adapter
(FC 5287; CCIN 5287)
|
Not supported | 1, 2, 3, 4, 5 | 5 | |
5288 | PCIe2 LP 2-port 10 GbE SFP+ Copper
Adapter (FC 5288; CCIN 5288)
|
Not supported | 1, 2, 3, 4, 5 | 5 | |
57082 | 10 Gb FCoE PCIe Dual-port Adapter
(FC 5708; CCIN 2B3B)
|
1, 3, 2, 4 | 24 and 44 | 1, 2, 3, 4, 5 | 25 and 45 |
57171 | 4-port 10/100/1000 Base-TX PCI Express Adapter (FC 5717;
CCIN 5717)
|
1, 3, 2, 4 | 24 and 42 | 1, 2, 3, 4, 5 | 25 and 45 |
57322 | 10 Gb Ethernet-CX4 PCI Express Adapter (FC 5732;
CCIN 2B43)
|
1, 3, 2, 4 | 24 and 44 | 1, 2, 3, 4, 5 | 25 and 45 |
5744 | PCIe2 2x10 GbE SR 2x1 GbE UTP
Adapter (FC 5744; CCIN 2B44)
|
Not supported | 1, 2, 3, 4, 5 | 5 | |
5745 | PCIe2 2x10 GbE SFP+ Copper 2x1
GbE UTP Adapter (FC 5745; CCIN 2B43)
|
Not supported | 1, 2, 3, 4, 5 | 5 | |
57671 | 2-port 10/100/1000 Base-TX Ethernet PCI Express Adapter (FC 5767;
CCIN 5767)
|
1, 3, 2, 4 | 24 and 44 | 1, 2, 3, 4, 5 | 25 and 45 |
57681 | 2-port Gigabit Ethernet-SX PCI Express Adapter (FC 5768;
CCIN 5768)
|
1, 3, 2, 4 | 24 and 44 | 5, 4, 3, 2, 1 | 25 and 45 |
57692 | 10 Gb Ethernet-SR PCI Express Adapter (FC 5769;
CCIN 2B44)
|
1, 2, 3, 4 | 24 and 44 | 1, 2, 3, 4, 5 | 25 and 45 |
57722 | 10 Gb Ethernet-LR PCI Express Adapter (FC 5772;
CCIN 576E)
|
1, 3, 2, 4 | 24 and 44 | 1, 2, 3, 4, 5 | 25 and 45 |
58991 | PCIe2 4-port 1 GbE Adapter (FC
5899; CCIN 576F)
|
4,1,2,31 | 24 and 44 | 6, 1, 2, 3, 4, 5 1 | 26 and 45 |
9055 | PCIe 2-port 1 GbE TX adapter
(FC 9055; CCIN 5767)
|
Not supported | 6, 1, 2, 3, 4, 52 | 1 | |
EC272 | PCIe2 LP 2-port 10 GbE RoCE SFP+
adapter (FC EC27; CCIN EC27)
|
Not supported | 7, 9, 8, 102 | 4 | |
EC282 | PCIe2 2-port 10 GbE RoCE SFP+
adapter (FC EC28; CCIN EC27)
|
Not supported | 1, 4, 2, 3, 52 | 5 | |
EC292 | PCIe2 LP 2-port 10 GbE RoCE SR
adapter (FC EC29; CCIN EC29)
|
Not supported | 7, 9, 8, 102 | 4 | |
EC2G | PCIe LP 2-Port 10 GbE SFN6122F
Adapter (FC EC2G; CCIN EC2G)
|
Not supported | 7, 9, 8, 101 | 4 | |
EC2H | PCIe LP 2-Port 10 GbE SFN5162F
Adapter (FC EC2H; CCIN EC2H)
|
Not supported | 7, 9, 8, 101 | 4 | |
EC2J | PCIe 2-Port 10 GbE SFN6122F Adapter
(FC EC2J; CCIN EC2G)
|
Not supported | 1, 2, 3, 4, 5, 61 | 4 | |
EC2K | PCIe 2-Port 10 GbE SFN5162F Adapter
(FC EC2K; CCIN EC2H)
|
Not supported | 1, 2, 3, 4, 51 | 4 | |
EC302 | PCIe2 2-port 10 GbE RoCE SR adapter
(FC EC30; CCIN EC29)
|
Not supported | 1, 4, 2, 3, 52 | 5 | |
EN0H | PCIe2 4-port (10 Gb FCoE, 1 GbE)
SFP+ Adapter (FC EN0H, CCIN 2B93)
|
Not supported | 1, 2, 3, 4, 52 | 5 | |
EN0J | PCIe2 LP 4-port (10 Gb FCoE,
1 GbE) SFP+ Adapter (FC EN0J, CCIN 2B93)
|
Not supported | 7, 8, 9, 102 | 4 | |
EN0K | PCIe2 4-port (10Gb FCoE and1GbE)
Copper and RJ45 Adapter (FC EN0K; CCIN 2CC1)
|
Not supported | 1, 2, 3, 4, 52 | 4 | |
EN0L | PCIe2 LP 4-port (10Gb FCoE and
1GbE) Copper and RJ45 Adapter (FC EN0L; CCIN 2CC1)
|
Not supported | 7, 9, 8, 10 | 4 | |
2728 | 4-port USB PCIe Adapter (FC 2728;
CCIN 57D1)
|
1, 2, 3, 4 | 24 and 44 | 5, 4, 3, 2, 1 | 25 and 45 |
4807 | PCIe Cryptographic Coprocessor
(FC 4807; CCIN 4765)
|
1, 3, 2, 4 | 2 | 5, 4, 3, 2, 1 | 2 |
4808 | PCIe Cryptographic Coprocessor
(FC 4808; CCIN 4765)
|
Installed in the expansion units and not supported in the system | 8 | Installed in the expansion units and not supported in the system | 8 |
52832 | PCIe2 LP 2-port 4X InfiniBand
QDR Adapter (FC 5283; CCIN 58E2)
|
5, 7, 6, 8 | 2 | 7, 9, 8, 10 | 2 |
52852 | PCIe2 2-port 4X InfiniBand QDR
Adapter (FC 5285; CCIN 58E2)
|
1, 3, 2, 4 | 2 | 1, 2, 3, 4, 5 | 2 |
20532 | PCIe RAID and SSD SAS Adapter
3 Gb Low-profile (FC 2053; CCIN 57CD)
|
6 and 8 | 2 | 8 and 10 | 2 |
20542 | PCIe RAID and SSD SAS Adapter
3 Gb Low-profile (FC 2054; CCIN 57CD)
|
Not supported | 2 | 2 and 5 or 3 and 5 | 2 |
20552 | PCIe RAID and SSD SAS Adapter
3 Gb with Blind-Swap Cassette (FC 2055; CCIN 57CD)
|
Installed in the expansion units and not supported in the system | 10 and 20 | Installed in the expansion units and not supported in the system | 10 and 20 |
5805 | PCIe 380 MB Cache Dual - x4 3
Gb SAS RAID Adapter (FC 5805; CCIN 574E)
|
1, 3, 2, 4 | 24 and 44 | 1, 2, 3, 4, 5 | 25 and 45 |
59012 | PCIe Dual - x4 SAS Adapter (FC
5901; CCIN 57B3)
|
1, 3, 2, 4 | 24 and 44 | 5, 4, 3, 2, 1 | 25 and 45 |
59032 | PCIe 380 MB Cache Dual x4 3 Gb
SAS RAID Adapter (FC 5903; CCIN 574E)
|
1, 3, 2, 4 | 1, 2, 3, 4, 5 | ||
5913 | PCIe2 1.8 GB Cache RAID SAS Tri-port
6 Gb Adapter (FC 5913; CCIN 57B5)
|
1, 3, 2, 4 | 18 and 24 | 1, 2, 3, 4, 5 | 18 and 24 |
ESA1 | PCIe2 RAID SAS Adapter Dual-port
6 Gb (FC ESA1; CCIN 57B4)
|
Not supported | 1, 2, 3, 4, 5 | 20 and 40 | |
ESA2 | PCIe2 RAID SAS Adapter Dual-port
6 Gb LP (FC ESA2; CCIN 57B4)
|
Not supported | 7, 9, 8, 10 | 2 | |
ESA3 | PCIe2 1.8 GB Cache RAID SAS Adapter
Tri-port 6Gb (FC ESA3; CCIN 57BB)
|
Not supported | 1, 2, 3, 4, 5 | 2 | |
2893 | PCI Express 2-Line WAN with Modem
(FC 2893; CCIN 576C)
|
1, 3, 2, 4 | 24 and 44 | 5, 4, 3, 2, 1 | 25 and 45 |
2894 | PCI Express 2-Line WAN with Modem
(FC 2894; CCIN 576C)
|
1, 3, 2, 4 | 24 and 44 | 5, 4, 3, 2, 1 | 25 and 45 |
EN13 | PCI Express 2-Line WAN with Modem
(FC EN13; CCIN 576C)
|
1, 3, 2, 4 | 24 and 44 | 5, 4, 3, 2, 1 | 25 and 45 |
EN14 | PCI Express 2-Line WAN with Modem
(FC EN14; CCIN 576C)
|
1, 3, 2, 4 | 24 and 44 | 5, 4, 3, 2, 1 | 25 and 45 |
ES09 | IBM Flash Adapter 90 (PCIe2
0.9TB) (FC ES09; CCIN 578A)
|
Not supported | 5, 4, 3, 1 Restriction: Not
supported in slot 2 (P1-C3) or slot 6 (P1-C1-C2) in 8205-E6D
|
20 | |
1High-bandwidth storage adapter. See the Performance notes before you install this adapter. 2Extra high-bandwidth adapter. See the Performance notes before you install this adapter. 3The adapters are installed in this order in the system for best performance. |
Performance notes
Use this information to determine the maximum number of adapters that can be placed in a system while still maintaining optimum performance.
Performance notes regarding GX++ channel adapters and I/O expansion units
The I/O expansion units must be limited to one expansion unit per GX++ channel controller (FC 5615 or FC EJ04) Do not connect multiple expansion units to the same GX++ channel controller.
Table 3 shows the slot placement priorities and the maximum number of specified adapters that can be installed for connectivity. However, for optimum performance, you might want to further limit the total number of high bandwidth and extra-high bandwidth adapters. If you must expand the I/O capacity of the system for extra-high bandwidth adapters, use high-performance I/O expansion units such as 5610, 5685, 5796, 5802, or 5877.
The following tables provide guidelines on the maximum number of high bandwidth and extra-high bandwidth adapters you can use and still maintain optimum performance.
Extra-high bandwidth storage adapters
System configuration | Adapters in system slots C4 to C7 | Low profile adapters in system slots C1-C1 to C1-C4 if FC 5610 or 5685 is used | Adapters per 5615 or EJ04 with one or more 5796 | Adapters per 5615 or EJ04 with one or two 5802 or 5877 | System maximum |
---|---|---|---|---|---|
System with one processor chip module unit | 3 (2 for 5735) | 31 (2 for 5273) | 4 | 6 (4 for 5735) | 9 |
System with two processor chip module units | 3 (2 for 5735) | 31 (2 for 5273) | 4 (8 in 2 drawers) | 6 (12 in 2 drawers) (4 or 8 for 5735) | 15 (10 for 5735) |
1Split adapters across both internal slots C4 to C7 and the four-slot riser slots C1-C1 to C1-C4 if FC 5610 or 5685 is used. You can install extra high-performance adapters in three out of the four base slots and in three out of four of FC 5610 or 5685 slots. |
Extra-high bandwidth Ethernet adapters
System configuration | Adapters in system slots C4 - C7 | Low profile adapters in system slots C1-C1 to C1-C4 if FC 5610 or FC 5685 is used | Adapters per 5615 or EJ04 with one or more 5796 | Adapters per 5615 or EJ04 with one or two 5802 or 5877 | System maximum |
---|---|---|---|---|---|
System with one processor chip module unit | 2 | 2 | 2 | 4 | 4 |
System with two processor chip module units | 2 | 2 | 2 (4 in 2 drawers) | 4 (8 in 2 drawers) | 8 |
For best performance, extra high-bandwidth Ethernet adapters must be installed in 5802 or 5877 expansion drawers when available, instead of using internal system unit slots. A maximum of two adapters in slots P1-C4 through P1-C7, and a maximum of two adapters in slots P1-C1-C1 through P1-C1-C4 can be installed. |