HSCPxxxx platform management error codes

These error codes can be displayed in a window that is displayed on the HMC screen during system configuration and operations.
HSCPxxxx error codes Message Recovery action
HSCP0001 The Backup Critical Data request completed successfully.  
HSCP0002 Ensure the media is inserted correctly into the drive and try the operation again. Verify that the media is inserted correctly in the drive and try the operation again.
HSCP0003 The Backup Critical Data request failed. An internal HMC error occurred. Contact your next level of support or your service provider.
HSCP0004 The media is write protected. Remove write protection and try the operation again. Remove write protection and try the operation again.
HSCP0005 The Backup Critical Data request is in progress. Please wait.  
HSCP0010 The Format Removable Media request completed successfully.  
HSCP0011 Ensure the media is inserted correctly into the drive and try the operation again.  
HSCP0012 The media is write protected. Remove the write protection and try the operation again.  
HSCP0013 An unknown error occurred. Replace the media and try the operation again.  
HSCP0014 The Format Removable Media request failed.  
HSCP0015 Please wait while the media is being formatted.  
HSCP0020 The Save Upgrade Data request completed successfully.  
HSCP0021 The Save Upgrade Data request failed.  
HSCP0022 The Save Upgrade Data request failed. Ensure the removable media is inserted correctly into the drive.  
HSCP0023 The media is write protected. Remove the write protection and try the operation again.  
HSCP0024 An error occurred while copying the upgrade data. Ensure the removable media is inserted correctly into the drive and retry the operation.  
HSCP0025 An error occurred while saving the upgrade data. Try the operation again. If the problem continues, contact your service representative.  
HSCP0026 An error occurred while trying to mount the media. Ensure the removable media is inserted correctly and try the operation again.  
HSCP0027 An error occurred while trying to unmount the media. Ensure the media is not being shared.  
HSCP0028 An non-recoverable error occurred. Refer to the HMC console log for detailed information.
  1. Refer to the HMC console log for more information.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0029 An error occurred while instantiating the save upgrade data target class.  
HSCP0030 An error occurred creating the file that processes the save upgrade data on the next reboot. Try the operation again.
  1. Rebuild the managed system. For details, see Updating managed system or frame information.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0031 Generating archives of subsystem files. Please wait.  
HSCP0040 The corrective service file was successfully downloaded to this system console. Press OK to continue and install this update.  
HSCP0041 The corrective service file was successfully applied. Wait until all tasks complete and reboot the HMC for the changes to take place.  
HSCP0042 An unrecoverable error occurred during the corrective service file download. Try the operation again. If the problem continues, contact your service representative.
  1. Try the task again.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0043 An unrecoverable error occurred during the corrective service installation. Try the operation again. If the problem continues, contact your service representative.
  1. Try the operation again.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0044 The removable media cannot be mounted. Ensure the media is inserted correctly into the drive and try the operation again.
  1. Verify that the removable media is correctly inserted in the drive and try the operation again.
  2. If the error persists, contact your next level of support or your service provider.
HSCP0045 The corrective service data is corrupt. Ensure the media is inserted correctly into the drive and try the operation again.
  1. Verify that the removable media is correctly inserted in the drive and try the operation again.
  2. If the error persists, contact your next level of support or your service provider.
HSCP0046 An error occurred while attempting to remotely connect to the server. Try the operation again. If the problem continues, contact your service representative.
  1. Try the operation again.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0047 An unspecified error occurred while downloading the corrective service file. Try the operation again. If the problem continues, contact your service representative.
  1. Try the operation again.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0048 An unknown error occurred. Try the operation again. If the problem continues, contact your service representative.
  1. Try the task again.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0049 The Install Corrective Service request is in progress. Please wait.  
HSCP0050 The download file is corrupt. Try the operation again.  
HSCP0051 The corrective service file download was unsuccessful. Refer to the text on the error message window.
HSCP0052 Successfully downloaded file. Installing, please wait.  
HSCP0053 Corrective service installation was successful.  
HSCP0054 Corrective service installation has failed. Refer to the text on the error message window.
HSCP0055 View the console log for details.  
HSCP0056 Halting service installation.  
HSCP0057 Corrective service file download in progress...  
HSCP0058 The corrective service file downloaded successfully, continuing...  
HSCP0060 The Customize Date/Time request completed successfully. Please reboot the HMC.
  1. Shut down and restart the HMC. For details, see Shutting down, rebooting, and logging off the HMC.
HSCP0061 The Customize Date/Time request failed.
  1. Verify that the removable media is correctly inserted in the drive and try the operation again.
  2. Try the operation with different media.
  3. Run PC Doctor to determine if there is a problem with the hardware.
  4. If the problem persists, contact your next level of support or your service provider.
HSCP0070 Enter an integer value between 1 and 99.  
HSCP0071 You cannot schedule an event in the past. Set the date and time to schedule the event in the future. Select a date and time that is after the present time.
HSCP0080 There are no system events.  
HSCP0081 Unable to display the log data.
  1. Verify that the removable media is correctly inserted in the drive and try the operation again.
  2. Try the operation with different media.
  3. Run PC Doctor to determine if there is a problem with the hardware.
  4. If the problem persists, contact your next level of support or your service provider.
HSCP0082 Unable to retrieve log data.
  1. Verify that the removable media is correctly inserted in the drive and try the operation again.
  2. Try the operation with different media.
  3. Run PC Doctor to determine if there is a problem with the hardware.
  4. If the problem persists, contact your next level of support or your service provider.
HSCP0083 An error occurred while processing the exit request.
  1. Verify that the removable media is correctly inserted in the drive and try the operation again.
  2. Try the operation with different media.
  3. Run PC Doctor to determine if there is a problem with the hardware.
  4. If the problem persists, contact your next level of support or your service provider.
HSCP0090 Cannot check both the 'Export default gateway' and 'Silent' options for 'routed'. Select either Export default gateway or Silent for the Routed option.
HSCP0091 Your updates have been saved to the system configuration files. You may need to reboot for all Network Settings changes to take affect. Restart the HMC.
HSCP0092 Unable to save your Network Settings updates to the system configuration files.
  1. Try the operation again.
  2. Shut down and restart the HMC.
  3. If the error persists, contact your next level of support or your service provider.
HSCP0093 Ethernet driver {1} cannot be set to {0}.
  1. Select a valid speed for the adapter.
  2. Select Auto-negotiate speed.
  3. Shut down and restart the HMC.
HSCP0100 No managed systems were detected that are attached to this system console.
  1. If you have a managed system attached, shut down and restart the HMC.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0101 No logical partitions have been defined for this managed system.
  1. Check to ensure that Service Focal Point is communicating correctly with the managed system.
  2. Shut down and restart the HMC.
  3. If the error persists, contact your next level of support or your service provider.
HSCP0102 A blank or incorrect entry was entered in the partition password field. Re-enter a valid password in the entry field and try the operation again.
HSCP0103 A blank or incorrect entry was entered in the listening port field. Re-enter a valid listening port and try the operation again.
HSCP0104 A blank or incorrect entry was entered in the IP address field. Re-enter the IP address and try the operation again.
HSCP0110 The Inventory Scout Services command completed successfully.  
HSCP0111 The Inventory Scout Services command request failed.
  1. Try the operation again.
  2. Shut down and restart the HMC.
  3. If the error persists, contact your next level of support or your service provider.
HSCP0112 The removable media cannot be mounted. Ensure the media is inserted correctly into the drive and try the operation again.
  1. Insert a correctly formatted diskette into the drive.
  2. Try using an alternate diskette.
  3. If the error persists, contact your next level of support or your service provider.
HSCP0113 The media is write protected. Remove the write protection and try the operation again. Remove write protection on the media and retry the operation.
HSCP0114 The Inventory Scout request failed. Ensure the removable media is inserted correctly into the drive.
  1. Insert the correctly formatted diskette into the drive.
  2. Try using an alternate diskette.
  3. If the error persists, contact your next level of support or your service provider.
HSCP0115 An error occurred while copying the Inventory Scout data. Verify that a blank formatted diskette is inserted correctly in the drive and retry the operation.
  1. Ensure that there is enough space on the media.
  2. Try using an alternate diskette and retry the operation.
  3. If the error persists, contact your next level of support or your service provider.
HSCP0116 An error occurred while compressing the Inventory Scout data. Try the operation again.  
HSCP0117 An error occurred while trying to unmount the media.  
HSCP0118 The Inventory Scout daemon was restarted successfully.  
HSCP0119 The Inventory Scout daemon cannot be restarted. Reboot the HMC and try the operation again.
  1. Try the operation again.
  2. Shut down and restart the HMC.
  3. If the error persists, contact your next level of support or your service provider.
HSCP0120 The CEC name is malformed.
  1. Shut down and restart the HMC.
  2. If the error persists, contact your next level of support or your service provider.
HSCP0121 The Inventory Scout request failed. An error occurred while copying data to removable media.
  1. Retry the operation.
  2. Restart the invscout daemon.
  3. If the error persists, contact your next level of support or your service provider.
HSCP0122 The system partition(s) did not respond to query attempts.
  1. Check to ensure that Service Focal Point is communicating correctly with the managed system.
  2. Shut down and restart the HMC.
  3. If the error persists, contact your next level of support or your service provider.
HSCP0123 Unable to start the terminal session using available error data. Return to Service Management interface and attempt to start the TTY session from there.
  1. Return to the Service Management interface and attempt to start the virtual terminal session.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0124 Unrecoverable error attempting to start a TTY session. Return to Service Management interface and attempt to start the TTY session from there.
  1. Return to the Service Management interface and attempt to start the virtual terminal session.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0125 An incorrect user ID and password combination was entered. Specify a valid user ID and password and try the operation again.
  1. Specify a valid user ID and password and retry the operation.
  2. Ensure that the remote service (FTP) site is operational.
  3. If the problem persists, contact your next level of support or your service provider.
HSCP0126 The corrective service file was not found on the server. Ensure the correct fully qualified path and filename has been specified for the 'Patch file' field and retry the operation.
  1. Specify a valid user ID and password and retry the operation.
  2. Ensure that the remote service (FTP) site is operational.
  3. If the problem persists, contact your next level of support or your service provider.
HSCP0127 An error occurred while unpacking the corrective service file. The file may be corrupt, or the HMC may have run out of disk space. Try the operation again. If the problem continues, contact your service representative.
  1. Shut down and restart the HMC.
  2. If the error persists, contact your next level of support or your service provider.
HSCP0128 A required file is missing from the service package. Contact your service representative. Contact your next level of support or your service provider.
HSCP0129 An attempt was made to apply incorrect service to this version of HMC software. Ensure the correct service filename has been specified and retry the operation.
  1. Ensure that the correct service file name has been entered and try the operation again.
  2. If the problem persists, contact your next level of support or your service provider.
HSCP0130 The target directory for service file extraction does not exist. Contact your service representative.
  1. Shut down and restart the HMC.
  2. If the error persists, contact your next level of support or your service provider.
HSCP0131 A fatal error occurred during service file installation. The system may be unstable. Contact your service representative.
  1. Shut down and restart the HMC.
  2. If the error persists, contact your next level of support or your service provider.
HSCP0135 Error {0} processing data on removable media.
  1. Attempt to download and apply the service file again.
  2. Save HMC upgrade data to preserve configuration data. For details, see Saving HMC upgrade data.
  3. Reinstall the HMC from the recovery CD as if doing an upgrade.
  4. If the problem persists, contact your next level of support or your service provider.
HSCP0136 The corrective service file was successfully copied to the HMC. Select the Frame 'Install Corrective Service' task to apply this update. Select the frame Install Corrective Service task to apply this update.
HSCP0137 The corrective service file was successfully downloaded to the HMC. Select the Frame 'Install Corrective Service' task to apply this update. Select the Frame Install Corrective Service task to apply this update.
HSCP0138 An internal error occurred during Save Upgrade Data processing. Refer to the HMC console log for detailed information and recovery actions. Refer to the HMC console log for detailed information and recovery actions.
HSCP0139 The DVD device is currently in use. Wait until all current DVD operations have been completed and try the operation again.  
HSCP0140 The DVD media is write protected. Remove the write protection and try the operation again.  
HSCP0141 Ensure the DVD media is inserted correctly into the drive and try the operation again.  
HSCP0142 An invalid or missing file system exists on the DVD media. Reformat the DVD and try the operation again.  
HSCP0143 The DVD device is not functioning correctly. Contact your service representative.  
HSCP0144 An error was detected while mounting the remote server. Verify that the parameters have been entered correctly and try the operation again.  
HSCP0145 The userId and password combination to log in to the remote server is incorrect. Ensure the combination is valid and try the operation again.  
HSCP0146 The temporary space used to create the backup archive has been exhausted. You can attempt to free disk space by deleting any pending dump files, or contact your service representative.  
HSCP0147 An error occurred while writing the informative description for this dump file. The backup task will now continue without this information.  
HSCP0148 No dump files exist on the remote server.  
HSCP0149 No detailed dump information exists for this archive.  
HSCP0150 An error occurred while reading the backup archive detailed information. The remote server may be busy. Try the operation again.  
HSCP0151 An error occurred while downloading the archive to this HMC. View the console log to see the detailed error information. Try the operation again.  
HSCP0152 An error occurred while copying the archive to this HMC. View the console log to see the detailed error information. Try the operation again.  
HSCP0153 The Backup Critical Console Data task was completed successfully.  
HSCP0154 The critical console data archive file was successfully offloaded to this HMC. Reboot the HMC and this data will be restored.  
HSCP0155 The task is unavailable. Please try again later.  
HSCP0156 An error occurred attempting to contact the remote system. Ensure a valid hostname or IP address has been entered and try the operation again.  
HSCP0157 An unrecoverable error occurred while transferring the file to the remote server. Verify that the target environment on the remote server can accommodate the request and try the operation again. If the failure persists, initiate the 'View Problem Logs' task from the Service Utilities menu for detailed error information. This will require 'hscpe' authority.  
HSCP0158 VPD collection was not successful. Verify all partition profiles associated with the managed system are active and accessible. Error details:  
HSCP0159 VPD collection from the managed system was successful.  
HSCP0160 VPD collection has failed. Verify all partition profiles associated with the managed system are active and accessible. Try the operation again. Error details: