Where allowed to run: All environments (*ALL) Threadsafe: No |
Parameters Examples Error messages |
The Display System Value (DSPSYSVAL) command displays the name and the value of the specified system value.
Top |
Keyword | Description | Choices | Notes |
---|---|---|---|
SYSVAL | System value | QABNORMSW, QACGLVL, QACTJOB, QADLACTJ, QADLSPLA, QADLTOTJ, QALWJOBITP, QALWOBJRST, QALWUSRDMN, QASTLVL, QATNPGM, QAUDCTL, QAUDENDACN, QAUDFRCLVL, QAUDLVL, QAUDLVL2, QAUTOCFG, QAUTORMT, QAUTOSPRPT, QAUTOVRT, QBASACTLVL, QBASPOOL, QBOOKPATH, QCCSID, QCENTURY, QCFGMSGQ, QCHRID, QCHRIDCTL, QCMNARB, QCMNRCYLMT, QCNTRYID, QCONSOLE, QCRTAUT, QCRTOBJAUD, QCTLSBSD, QCURSYM, QDATE, QDATETIME, QDATFMT, QDATSEP, QDAY, QDAYOFWEEK, QDBFSTCCOL, QDBRCVYWT, QDECFMT, QDEVNAMING, QDEVRCYACN, QDSCJOBITV, QDSPSGNINF, QDYNPTYADJ, QDYNPTYSCD, QENDJOBLMT, QFRCCVNRST, QHOUR, QHSTLOGSIZ, QIGC, QIGCCDEFNT, QIGCFNTSIZ, QINACTMSGQ, QINACTITV, QIPLDATTIM, QIPLSTS, QIPLTYPE, QJOBMSGQFL, QJOBMSGQMX, QJOBMSGQSZ, QJOBMSGQTL, QJOBSPLA, QKBDBUF, QKBDTYPE, QLANGID, QLEAPADJ, QLIBLCKLVL, QLMTDEVSSN, QLMTSECOFR, QLOCALE, QLOGOUTPUT, QMAXACTLVL, QMAXJOB, QMAXSGNACN, QMAXSIGN, QMAXSPLF, QMCHPOOL, QMINUTE, QMLTTHDACN, QMODEL, QMONTH, QPASTHRSVR, QPFRADJ, QPRBFTR, QPRBHLDITV, QPRCFEAT, QPRCMLTTSK, QPRTDEV, QPRTKEYFMT, QPRTTXT, QPWDCHGBLK, QPWDEXPITV, QPWDEXPWRN, QPWDLMTAJC, QPWDLMTCHR, QPWDLMTREP, QPWDLVL, QPWDMAXLEN, QPWDMINLEN, QPWDPOSDIF, QPWDRQDDGT, QPWDRQDDIF, QPWDRULES, QPWDVLDPGM, QPWRDWNLMT, QPWRRSTIPL, QQRYDEGREE, QQRYTIMLMT, QRCLSPLSTG, QRETSVRSEC, QRMTIPL, QRMTSIGN, QRMTSRVATR, QSAVACCPTH, QSCANFS, QSCANFSCTL, QSCPFCONS, QSECOND, QSECURITY, QSETJOBATR, QSFWERRLOG, QSHRMEMCTL, QSPCENV, QSPLFACN, QSRLNBR, QSRTSEQ, QSRVDMP, QSSLCSL, QSSLCSLCTL, QSSLPCL, QSTGLOWACN, QSTGLOWLMT, QSTRPRTWTR, QSTRUPPGM, QSTSMSG, QSVRAUTITV, QSYSLIBL, QTHDRSCADJ, QTHDRSCAFN, QTIMADJ, QTIME, QTIMSEP, QTIMZON, QTOTJOB, QTSEPOOL, QUPSDLYTIM, QUPSMSGQ, QUSEADPAUT, QUSRLIBL, QUTCOFFSET, QVFYOBJRST, QYEAR | Required, Positional 1 |
OUTPUT | Output | Optional, Positional 2 |
Top |
Specifies the name of the system value that is displayed.
This is a required parameter.
The system values are:
If a command does not have an *ADVANCED level interface, *INTERMED is used.
Changes made to this system value take effect immediately.
Note:
Note: *JOBDTA is composed of two values to allow you to better customize your auditing. If you specify both of the values, you will get the same auditing as if you specified *JOBDTA. The following values make up *JOBDTA.
Note: *NETCMN is composed of several values to allow you to better customize your auditing. If you specify all of the values, you will get the same auditing as if you specified *NETCMN. The following values make up *NETCMN.
Note: *SECURITY is composed of several values to allow you to better customize your auditing. If you specify all of the values, you will get the same auditing as if you specified *SECURITY. The following values make up *SECURITY.
Note: *JOBDTA is composed of two values to allow you to better customize your auditing. If you specify both of the values, you will get the same auditing as if you specified *JOBDTA. The following values make up *JOBDTA.
Note: *NETCMN is composed of several values to allow you to better customize your auditing. If you specify all of the values, you will get the same auditing as if you specified *NETCMN. The following values make up *NETCMN.
Note: *SECURITY is composed of several values to allow you to better customize your auditing. If you specify all of the values, you will get the same auditing as if you specified *SECURITY. The following values make up *SECURITY.
Note: If this system value is set to zero (0), the work in these jobs is done in QSYSARB and QLUS system jobs as opposed to the communication arbiters.
When a job being ended has a signal handling procedure for the asynchronous signal SIGTERM, the SIGTERM signal is generated for that job. When the signal handling procedure for the SIGTERM signal is given control, the procedure can take the appropriate actions to avoid undesirable results such as application data that has been partially updated. If the SIGTERM signal handler has not completed in the specified time, the system ends the job.
When the job is ended in a controlled manner, the maximum time for the SIGTERM signal handler is specified on the command. When the job is ended in an immediate manner, the maximum time for the SIGTERM signal handler is specified by this system value. This time limit is used when ending one job, when ending all the jobs in a subsystem, or when ending all jobs in all subsystems. After two minutes, the system operator can use the End Job (ENDJOB) command with OPTION(*IMMED) to override the QENDJOBLMT value and end individual jobs immediately.
A change to this value takes effect immediately. Jobs that are already ending are not affected.
When an object is converted, its digital signature is discarded. The state of the converted object is set to user state. After conversion, objects will have a good validation value and are not suspected of having been tampered with.
Local jobs that are currently signed on to a remote system are excluded. For example, a work station is directly attached to system A, and system A has QINACTIV set on. If Display Station Pass-through or TELNET is used to sign on to system B, this work station is not affected by the QINACTITV value set on system A. Changes made to this system value take effect immediately.
QIPLDATTIM is a single system value with two parts:
*NONE, which indicates that no timed automatic IPL is scheduled, can be specified instead of a specific date and time.
The following example shows how to change the IPL date and time to September 10, 1993 (QDATFMT is MDY) at 9:00 a.m.
CHGSYSVAL SYSVAL(QIPLDATTIM) VALUE('091093 090000')
Note: You should only use this for problem analysis because it prevents other devices on the work station controller from being used.
This system value is determined by the year offset that is associated with the time zone description specified in the system value QTIMZON. A change to a different time zone description for QTIMZON may result in a different associated adjustment.
QLEAPADJ cannot be changed to a value that is different than its current value. If an attempt is made to do so, the diagnostic message CPD168B will be issued. The value of QLEAPADJ is managed by the system.
A change to this system value takes effect immediately. The shipped value may be different for different countries.
Changes made to this system value take effect immediately for jobs entering the system after the change is made.
Note: Changes to the size of a pool may require pages to be written to auxiliary storage. The time required for the system to complete a large change may be greater than your default wait time. If this occurs, message CPF1001 (Wait time expired for system response.) is issued, even though the change completes.
If you create journal QPFRADJ in library QSYS, the dynamic tuning program keeps a record of the changes made to storage pool sizes, activity levels, and the performance level of the system when the changes were made (faulting rates per pool, pool sizes, and activity levels).
An IPL may be required for this system value to take effect. See the System Values topic in the IBM i Information Center at http://www.ibm.com/systems/i/infocenter/ for additional information.
For more information on partitions, see the Logical Partitions topic in the IBM i Information Center at http://www.ibm.com/systems/i/infocenter/.
Note: If the QPWDRULES system value specifies any value other than *PWDSYSVAL, this system value will be ignored when new passwords are checked to see if they are formed correctly. In addition, this system value cannot be changed if QPWDRULES has a value other than *PWDSYSVAL.
Note: This system value is ignored if the system is operating at QPWDLVL 2 or 3.
Note: If the QPWDRULES system value specifies any value other than *PWDSYSVAL, this system value will be ignored when new passwords are checked to see if they are formed correctly. In addition, this system value cannot be changed if QPWDRULES has a value other than *PWDSYSVAL.
Note: If the QPWDRULES system value specifies any value other than *PWDSYSVAL, this system value will be ignored when new passwords are checked to see if they are formed correctly. In addition, this system value cannot be changed if QPWDRULES has a value other than *PWDSYSVAL.
Changing this system value requires careful consideration. If your system connects to other systems in a network then all systems must be able to run with the password rules that will be in effect.
See the System i Security Reference, SC41-5302 publication for additional considerations prior to changing this system value.
Changes to this system value will take effect on the next IPL.
If the system is operating at QPWDLVL 0 or 1, the valid range is 1-10. If the system is operating at QPWDLVL 2 or 3, the valid range is 1-128.
Note: If the QPWDRULES system value specifies any value other than *PWDSYSVAL, this system value will be ignored when new passwords are checked to see if they are formed correctly. In addition, this system value cannot be changed if QPWDRULES has a value other than *PWDSYSVAL.
If the system is operating at QPWDLVL 0 or 1, the valid range is 1-10. If the system is operating at QPWDLVL 2 or 3, the valid range is 1-128.
Note: If the QPWDRULES system value specifies any value other than *PWDSYSVAL, this system value will be ignored when new passwords are checked to see if they are formed correctly. In addition, this system value cannot be changed if QPWDRULES has a value other than *PWDSYSVAL.
Note: If the QPWDRULES system value specifies any value other than *PWDSYSVAL, this system value will be ignored when new passwords are checked to see if they are formed correctly. In addition, this system value cannot be changed if QPWDRULES has a value other than *PWDSYSVAL.
Note: If the QPWDRULES system value specifies any value other than *PWDSYSVAL, this system value will be ignored when new passwords are checked to see if they are formed correctly. In addition, this system value cannot be changed if QPWDRULES has a value other than *PWDSYSVAL.
Note: If any value other than *PWDSYSVAL is specified for QPWDRULES, the QPWDLMTAJC, QPWDLMTCHR, QPWDLMTREP, QPWDMAXLEN, QPWDMINLEN, QPWDPOSDIF, and QPWDRQDDGT system values are ignored when a new password is checked to see if it is formed correctly.
Only one *DGTMAXn value can be specified. If a *DGTMINn value is also specified, the n value specified for *DGTMAXn must be greater than or equal to the n value specified for *DGTMINn.
Only one *DGTMINn value can be specified. If a *DGTMAXn value is also specified, the n value specified for *DGTMAXn must be greater than or equal to the n value specified for *DGTMINn.
Only one *LTRMAXn value can be specified. If a *LTRMINn value is also specified, the n value specified for *LTRMAXn must be greater than or equal to the n value specified for *LTRMINn.
Only one *LTRMINn value can be specified. If a *LTRMAXn value is also specified, the n value specified for *LTRMAXn must be greater than or equal to the n value specified for *LTRMINn.
If the system is operating at QPWDLVL 0 or 1, the valid range is 1-10. If the system is operating at QPWDLVL 2 or 3, the valid range is 1-128.
The nnn value specified must be large enough to accommodate all *MIXCASEn, *DGTMAXn, *LTRMAXn, *SPCCHRMAXn, first and last character restrictions, and non-adjacent character requirements.
If *MINLENnnn is also specified, the nnn value specified for *MAXLENnnn must be greater than or equal to the nnn value specified for *MINLENnnn.
If no *MAXLENnnn value is specified, a value of *MAXLEN10 is assumed if the system is operating with a QPWDLVL value of 0 or 1 or a value of *MAXLEN128 is assumed if the system is operating with a QPWDLVL value of 2 or 3.
If the system is operating at QPWDLVL 0 or 1, the valid range is 1-10. If the system is operating at QPWDLVL 2 or 3, the valid range is 1-128.
If *MAXLENnnn is also specified, the nnn value specified for *MAXLENnnn must be greater than or equal to the nnn value specified for *MINLENnnn.
If no *MINLENnnn value is specified, a value of *MINLEN1 is assumed.
Only one *MIXCASEn value can be specified.
If a *LTRMAXn value is specified, the n value specified for *LTRMAXn must be greater than or equal to two times the n value specified for *MIXCASEn.
When the system is operating with a QPWDLVL of 0 or 1, *REQANY3 has the same effect as if *DGTMIN1, *LTRMIN1, and *SPCCHRMIN1 were all specified.
Only one *SPCCHRMAXn value can be specified. If a *SPCCHRMINn value is also specified, the n value specified for *SPCCHRMAXn must be greater than or equal to the n value specified for *SPCCHRMINn.
Only one *SPCCHRMINn value can be specified. If a *SPCCHRMAXn value is also specified, the n value specified for *SPCCHRMAXn must be greater than or equal to the n value specified for *SPCCHRMINn.
Changes to this value take effect when a PWRDWNSYS command is entered.
Whether or not a partition is IPLed at the same time as the system is powered on depends on the partition's configuration value for IPL action.
On partitioned systems, this system value must be changed from the service processor's Advanced System Management Interface (ASMI).
For more information on partitions, see the Logical Partitions topic in the IBM i Information Center at http://www.ibm.com/systems/i/infocenter/.
Note: Using this value can have adverse effects on system performance. More information is in the Files and file systems category in the IBM i Information Center at http://www.ibm.com/systems/i/infocenter/.
Note: Any telephone call will cause the system to IPL.
Whether or not a partition is IPLed at the same time as the system is powered on depends on the partition's configuration value for IPL action.
On partitioned systems, this system value must be changed from the service processor's Advanced System Management Interface (ASMI).
For more information on partitions, see the Logical Partitions topic in the IBM i Information Center at http://www.ibm.com/systems/i/infocenter/.
If the error is to be logged unconditionally, a PARable message is sent to QSYSOPR and an entry is created in the problem log. If the reporting component provides error data, a spooled file is created to contain the data. The spooled file name is stored in the error log and problem log entries.
If the error is to be conditionally logged, the decision to log the error will be made by the policy based Service Monitor. If the decision is to log the problem, an entry is created in the problem log. The problem data will be stored in a problem data library and the problem record entry will be updated with the name of the library.
For details on System SSL and SSL ciphers, see the SSL section of the Security Reference information in the IBM i Information Center at http://www.ibm.com/systems/i/infocenter/.
A change to this system value takes effect immediately for all subsequent System SSL sessions. The shipped value is *RSA_AES_128_CBC_SHA, *RSA_RC4_128_SHA, *RSA_RC4_128_MD5, *RSA_AES_256_CBC_SHA, *RSA_3DES_EDE_CBC_SHA, *RSA_DES_CBC_SHA, *RSA_EXPORT_RC4_40_MD5, *RSA_EXPORT_RC2_CBC_40_MD5, *RSA_NULL_SHA, and *RSA_NULL_MD5.
Note: You must have *IOSYSCFG, *ALLOBJ, and *SECADM special authorities to change this system value.
A cipher cannot be added to QSSLCSL if the required SSL protocol value for the cipher suite is not set for the QSSLPCL (SSL protocol list) system value.
Note: System SSL uses the sequence of the values in QSSLCSL to order the System SSL default cipher specification list. The default cipher specification list entries are system defined and can change on release boundaries. A default cipher removed from QSSLCSL results in the cipher's removal from the default list. The default cipher is added back to the default cipher specification list when it is added back into QSSLCSL. It is not possible to add other ciphers to the default list beyond the system defined set for the release.
For details on System SSL and SSL ciphers, see the SSL section of the Security Reference information in the IBM i Information Center at http://www.ibm.com/systems/i/infocenter/.
A change to this system value takes effect immediately. The shipped value is *OPSYS.
Note: You must have *IOSYSCFG, *ALLOBJ, and *SECADM special authorities to change this system value.
Note: *OPSYS allows the values to be automatically updated with newer and stronger ciphers when installing to a future release that has new cipher suite capabilities.
Note: Additional cipher suite capabilities will not be added automatically when moving to a future release. You will have to determine what if any new cipher suites are available and add them to the QSSLCSL (SSL cipher specification list) system value manually.
For details on System SSL and SSL Protocols, see the SSL section of the Security Reference information in the IBM i Information Center at http://www.ibm.com/systems/i/infocenter/.
A change to this system value takes effect immediately for all subsequent System SSL sessions. The shipped value is *OPSYS.
Note: You must have *IOSYSCFG, *ALLOBJ, and *SECADM special authorities to change this system value.
The thread resources affinity level can be set to the following values:
Time adjustment software should check QTIMADJ prior to starting. If QTIMADJ has an identifier for other time adjustment software, then the software being started should notify the user of this potential conflict and confirm that this time adjustment software should be started. When QTIMADJ is *NONE the software should update QTIMADJ to identify that it is now responsible for adjusting the system clock. Time adjustment software should check QTIMADJ again prior to ending. QTIMADJ should be set to *NONE only if the current value identifies this time adjustment software that is ending. Changes made to this system value take effect immediately. The shipped value is *NONE.
This value affects jobs for which *SYSVAL is specified as the time separator. When specifying time on commands, users must use the time separator specified for their job or no time separator. If a time separator different from the job's time separator is used to specify time on a command, the command will fail.
For more information on partitions, see the Logical Partitions topic in the IBM i Information Center at http://www.ibm.com/systems/i/infocenter/.
This system value has no effect on the following:
The following values can be specified:
Note: This system value must be the same as the offset that is associated with the time zone description specified in the system value QTIMZON. A change to a different time zone description for QTIMZON may result in a different associated offset. The system value QUTCOFFSET will be changed as well to match this new offset. QUTCOFFSET cannot be changed to a value that is different than the offset currently associated with QTIMZON. If an attempt is made to do so, the diagnostic message CPD1687 will be issued.
Top |
Specifies whether the output from the command is displayed at the requesting work station or printed with the job's spooled output.
Top |
Top |
*ESCAPE Messages
Top |