4089 - Gripper was unable to put cartridge
A gripper on the robotic accessor was unable to place a cartridge into a slot, magazine, or drive. This could be caused by faulty grippers or due to an obstruction in the destination location for the cartridge. This fix procedure describes how to diagnose the issue and, if needed, remove a stuck cartridge from the gripper.
Fix procedure
- If front LED lighting is not solid yellow, Put the library in service mode:
- From the management GUI., go to .
- Choose option and then click the button.
- Open the front door.
- If a cartridge is inside the gripper, follow the “Cartridge removal from gripper” procedure.
- Look around the target area for obstructions and clear them. If no obstructions were found go to
5, otherwise go to Step 7.Additional Troubleshooting:
- Check if the target slot is full, by pushing on the front cartridge.
- Manually move the grippers pickers and confirm no part is damaged and it moves freely. This can be done by moving the motor pulley with your fingers. Pay attention to the gripper fingers to ensure they are not damaged.
- Ensure that the gripper motor cable connector and cartridge present sensor cable connector are firmly seated at the Gripper Control Card (GCC) and no damage to cables is visible.
- Close the door.
- Take the library out of service mode:
- From the management GUI., go to .
- Choose option and then click the button.
- If you performed the check in Step 4.a and the location was full, perform an all tiers inventory from the Management GUI.
Attention: If the problem has occurred multiple times and still not resolved, contact
IBM support to discuss the robotic accessor replacement.
Damaged Components
During the procedure, if any part is found
physically damaged, replace the applicable Customer Replacement Unit (CRU). See Customer service procedures.