The IBM® PureFlex™ System Express example configuration 2A consists of the IBM Flex System V7000 Controller + FCoE-capable mezzanine card and dual IBM Flex System 10 Gb Converged Scalable Switches. This configuration is also known as GA4 configuration 2A.
Index letter | Machine type, model, or feature code | Description | Quantity |
---|---|---|---|
A | 7955-01M | IBM Flex System Manager | 1 |
B | Any | Compute nodes | 1, plus optional 12 more |
C | 7893-92X | IBM Flex System chassis | 1 |
D | CN4093 | IBM Flex System 10 Gb Converged Scalable Switch See Table 2 for mezzanine card options. |
2 |
E | 4939-A49 | IBM Flex System V7000 Controller + FCoE-capable mezzanine card | 1 plus optional 2 or 3 |
G | 2076-224 | IBM Storwize® V7000 Expansion Enclosure | Optional *. Up to 9 per controller. The maximum number of expansion enclosures connected to a single controller is 9 minus the IBM Flex System V7000 Expansion Enclosure or Enclosures. |
F | 4939-A29 | IBM Flex System V7000 Expansion Enclosure | Optional, 0, 1, or 2 |
H | 7226-1U3 | IBM Multimedia Storage Enclosure | Optional * |
K | 7316-TF3 | Flat Panel Rack-Mounted Monitor and Keyboard | Optional * |
J | 7014-S25 | First IBM Entry Rack Cabinet Model S25 (25U standard rack) | Optional |
7953-94X | IBM PureFlex System 42U Rack | Optional | |
7953-94X | IBM PureFlex System (overflow 42U rack) | ||
* Add either an IBM Entry Rack Cabinet Model S25 (25U standard rack) or IBM PureFlex System 42U rack to your order to put this device in a rack. |
Machine type, model, or feature code | Description | Quantity | |
---|---|---|---|
The following mezzanine cards can be ordered with the IBM Flex System 10 Gb Converged Scalable Switch: | |||
EC24 | Power Architecture®: IBM Flex System CN4058 8-port 10 Gb Converged Adapter | 1 or 2 | |
A1R1 | X architecture: IBM Flex System CN4054 10 Gb Virtual Fabric Adapter. Note: This mezzanine card is used for an LOM-less system board, or when extra NIC ports are needed. These include: 8737-15X (FC A1BD), 7906-25X (FC A1VN), and 7917-45X (FC A2BD). | 1 or 2 | |
A1R0 | X architecture: IBM Flex System Virtual Fabric Adapter Upgrade to include iSCSI and FCoE. Note: A1R0 is pre-applied to each server that contains A1R1. | 1 or 2 | |
A2TD | X architecture: IBM Flex System Embedded 10 Gb Virtual Fabric Upgrade (Feature on Demand to provide FCoE and iSCSI support). Note: A2TD is applied to 8737-15X (FC A1BC) and 7917-45X (FC A2BC). | 1 or 2 | |
Note: You can have two mezzanine cards per full wide compute node. Or, you can have one mezzanine card per half wide compute node.
|
Feature code | Base | Expansion | Description | Feature code - Service agreement | |
---|---|---|---|---|---|
5639-NZ7 | X | IBM Storwize Family Software for Flex System V7000, v7.1 or later | 5639-ZZA - 1-year SWMA | ||
5639-EX7 | X | IBM Flex System V7000 External Virtualization (EV) Software, v7.1, or later | 5639-EXA - 1-year EV SWMA | ||
5639-RE7 | X | IBM Flex System V7000 Remote Mirroring Software (RMS), v7.1 | 5639-REA - 1-year RM SWMA | ||
5639-CM7 | X | IBM Flex System V7000 Real-time Compression™ (RTC) Software, v7.1, or later | 5639-CMA - 1-year RTC SWMA |
Feature code | Base | Expansion | Description | Feature code - Service agreement | |
---|---|---|---|---|---|
5765-FMX | X | IBM Flex System Manager management software, v1.1, or later | 5660-FMX - 1-year SWMA | ||
5765-FMS | X | IBM Flex System Manager management software Advanced |
Feature code | Base | Expansion | Description | Feature code - Service agreement | |
---|---|---|---|---|---|
5639-W28 | X | Windows 2008 R2 | |||
5639-CAL | X | Windows 2008 Client Access | |||
Xxxx-xxx | X | Windows 2012 | |||
X | VMware View license and subscription entitlement | ||||
5639-OSX | X | Red Hat Enterprise Linux (RHEL) for x86 | |||
5639-11X | X | SUSE Linux Enterprise Server (SLES) for x86 |
Feature code | Base | Expansion | Description | Feature code - Service agreement | |
---|---|---|---|---|---|
5765-PVS | X | PowerVM® Standard Edition v2.2.1.4, or later (for Power® compute nodes) | 5771-PVS - 1-year SWMA | ||
EBK3 | X | ESXi USB Hypervisor Key (VMware version 5, update 1) (for X architecture compute nodes) |
Feature code | Base | Expansion | Description | Feature code - Service agreement | |
---|---|---|---|---|---|
5765-PSE | X | PowerSC™ Standard v1.1, or later (if AIX® selected) | 5660-PSE - 1-year SWMA |
Feature code | Base | Expansion | Description | Feature code - Service agreement | |
---|---|---|---|---|---|
5765-SCP | X | IBM SmartCloud® Entry for IBM Flex System (optional) Notes:
|
5660-SCP - 1-year SWMA |
Feature code | Description |
---|---|
1-year, 9 a.m. x 5 p.m., Software maintenance (SWMA) | |
3-years, 9 a.m. x 5 p.m., Next business day service hardware maintenance (HWMA) | |
Maintenance and Technical Support (MTS) offering: 3-years with one microcode analysis per year | |
Optional 3-day PureFlex bundled services: | |
6911-300 | First compute node = POWER® |
6911-100 | First compute node = System x® |