00E40024
Explanation
Internal protocols required for utility serialization were violated. Specifically, utility serialization cleanup was not invoked upon completion of utility processing. This error can happen if during utility restart, the utility control statement is modified improperly.
System action
The utility job step is terminated, placing the utility in the stopped state.
Operator response
An operator with SYSOPR authority can issue the TERM UTILITY command to release the resources claimed by the stopped utility, however this action might not be necessary.
System programmer response
Determine the failing environment. If you suspect an error in Db2, you might need to report the problem. For information about identifying and reporting the problem, see Collecting diagnostic data.
Problem determination
Collect the following diagnostic items:
- REPAIR dump of all SYSUTIL pages.