00C50003
Explanation
This could be either a user or a system error. SPUFI was unable to obtain the required storage via GETMAIN.
System action
SPUFI task abends. User returns to ISPF main menu.
System programmer response
If the problem persists, the standard SPUFI documentation should be collected. Refer to X'C5......' codes for information about obtaining dumps and displaying message IDs.
User response
If the problem persists, notify the system programmer. You may have to specify a larger machine size at logon time.
Problem determination
Register 2 contains the amount of storage that was requested. Message DSNE392E, in the ISPF log data set, gives the name of the module that issued this abend.
Collect the following diagnostic items:
- SYSABEND, SYSUDUMP, or SYSMDUMP output.
- Listing of the ISPF log for the session involved in the problem.