POWER7 information

TPMD_OV

The thermal power management firmware has detected that the system is operating without power supply redundancy.

The maximum power limit for the operational power supply has been reached and action has been taken to reduce power consumption. A power-related SRC might or might not have been logged.

If you need additional information for failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to find additional location codes, part numbers, or replacement procedures for your system.

Complete the following steps.

  1. Check the error log for power-related SRCs (1xxx yyyy). Did you find a power-related SRC?
    • No: Continue with the next step.
    • Yes: Resolve the problem using the power-related SRC. This ends the procedure.
  2. Replace the power supply. If there are two power supplies, check the LEDs on the power supplies (see PWRSPLY for descriptions of the LEDs and their meaning). If the LEDs indicate that one of the power supplies is failing, replace it first. If the LEDs do not indicate a failure, replace the power supplies one at a time. Did replacing power supplies resolve the problem?
    • No: Continue with the next step.
    • Yes: This ends the procedure.
  3. Replace the TPMD card. This ends the procedure.