POWER7 information
FWPCI5
Look here for information about FWPCI5 symbolic FRU.
If you receive symbolic FRU FWPCI5, perform the following procedure:
- Is a location code associated with the checkpoint?
- No: Go to PFW1548: Memory and processor subsystem problem isolation procedure. This ends the procedure.
- Yes: Continue with the next step.
- Replace the following, one at a time, until the problem is resolved:
- The FRU identified by the location code, see the system unit service information for the FRU part numbers.
- I/O backplane, use the following table to determine the part
number for the field replaceable unit (FRU).
CCIN or FFC Type and model Part number Description Location code 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D with failing slot on the system backplane See System parts. System backplane Un-P1 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D with failing slot on the PCI riser card feature (if installed) See System parts. PCI riser card Un-P1-C1 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8233-E8B, 8236-E8C, 8268-E1D See System parts. System backplane Un-P1 8248-L4T, 8408-E8D, 8412-EAD, 9109-RMD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD See System parts. I/O backplane Un-P2 5796, 7314-G30 See System parts. I/O backplane Un-P1 If you need additional information for failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to find additional location codes, part numbers, or replacement procedures for your system.
This ends the procedure.