FCIOA

The Fibre Channel I/O adapter is the failing item.

If the attached device is owned by a Virtual I/O Server partition see Troubleshooting the Virtual I/O Server to determine the parts to replace. Otherwise, replace the Fibre Channel I/O adapter using the I/O adapter location information in the service action log if it is available. If the location is not available, find the address of the I/O adapter, see the System reference code format description. Use the address to find the location. See Part locations and location codes. If an I/O Processor SRC sent you here, replace the Fibre Channel I/O adapter associated with the I/O processor that logged the SRC.

Use the following table to determine the part number for the field replaceable unit (FRU).

CCIN or FFC Type and model Part number Description Location code
2787   80P6417 Fibre Channel IOA (for disk drive attachment only) Un-Px-Cy
280D   03N5014 4 Gbps Fibre Channel (1 Port) adapter Un-Px-Cy
280E   03N5016 PCI-X Fibre Channel disk controller Un-Px-Cy
5704   80P6416 Fibre Channel IOA (for removable media attachment only) Un-Px-Cy
576B   32N1294 4 Gbps Fibre Channel (2 Port) adapter Un-Px-Cy
5774   10N7255 Gigabit PCI Express Dual Port Fibre Channel adapter Un-Px-Cy
577D   10N9824 8 Gigabit PCI Express Dual Port Fibre Channel adapter Un-Px-Cy
57FC   To determine the FRU part number, remove the adapter from the system. Fibre Channel IOA Un-Px-Cy