FCIOA
The Fibre Channel I/O adapter is the failing item.
If the attached device is owned by a Virtual I/O Server partition see Troubleshooting the Virtual I/O Server to determine the parts to replace. Otherwise, replace the Fibre Channel I/O adapter using the I/O adapter location information in the service action log if it is available. If the location is not available, find the address of the I/O adapter, see the System reference code format description. Use the address to find the location. See Part locations and location codes. If an I/O Processor SRC sent you here, replace the Fibre Channel I/O adapter associated with the I/O processor that logged the SRC.
Use the following table to determine the part number for the field replaceable unit (FRU).
| CCIN or FFC | Type and model | Part number | Description | Location code |
|---|---|---|---|---|
| 2787 | 80P6417 | Fibre Channel IOA (for disk drive attachment only) | Un-Px-Cy | |
| 280D | 03N5014 | 4 Gbps Fibre Channel (1 Port) adapter | Un-Px-Cy | |
| 280E | 03N5016 | PCI-X Fibre Channel disk controller | Un-Px-Cy | |
| 5704 | 80P6416 | Fibre Channel IOA (for removable media attachment only) | Un-Px-Cy | |
| 576B | 32N1294 | 4 Gbps Fibre Channel (2 Port) adapter | Un-Px-Cy | |
| 5774 | 10N7255 | Gigabit PCI Express Dual Port Fibre Channel adapter | Un-Px-Cy | |
| 577D | 10N9824 | 8 Gigabit PCI Express Dual Port Fibre Channel adapter | Un-Px-Cy | |
| 57FC | To determine the FRU part number, remove the adapter from the system. | Fibre Channel IOA | Un-Px-Cy |