AUXCBL

Replace the SCSI cable that connects the auxiliary cache I/O adapter to the storage I/O adapter.

  1. Are you working on a 571F/575B combination storage and auxiliary cache IOA card set (uses two card slot locations)?
    Yes:
    This symbolic FRU does not apply. The SCSI cable is not a FRU on this card set. Go to the next item in the failing item list. This ends the procedure.
    No:
    Continue with the next step.
  2. Find the location of the auxiliary cache I/O adapter:
    1. Determine the address of the auxiliary cache I/O adapter. See the System reference code format description.
    2. Determine the location of the auxiliary cache I/O adapter. See Part locations and location codes for the model on which you are working.
  3. Replace the SCSI cable that connects the auxiliary cache I/O adapter to the storage I/O adapter. See Finding parts, locations, and addresses for cable part number information.
Note: To replace the SCSI cable concurrently, you must use concurrent maintenance to power off the auxiliary cache I/O adapter. Replace the cable and then use concurrent maintenance to power on the auxiliary cache I/O adapter. Do not replace the cable when both adapters are powered on.