Map codes to hardware.
The following diagrams show field replaceable unit (FRU) layout in the 7311-D20 expansion units. Use these diagrams with the following tables.
The following table gives the components available for callout on the 7311-D20 expansion units. It matches those components with the FRU containing the component. The other columns give location information, a link to a removal and replacement procedure, and additional information.
Failing item name | Symbolic failing item name | Physical location code | Identify LED | Link to part number | Failing item removal and replacement procedures |
---|---|---|---|---|---|
Backplane
|
TWRCARD |
Un-P1 | Yes | 28BE | I/O backplane assembly |
PCI adapter in slot 1 | PIOCARD |
Un-P1-C01 | Yes | PCI adapter | |
PCI adapter in slot 2 | PIOCARD |
Un-P1-C02 | Yes | PCI adapter | |
PCI adapter in slot 3 | PIOCARD |
Un-P1-C03 | Yes | PCI adapter | |
PCI adapter in slot 4 | PIOCARD |
Un-P1-C04 | Yes | PCI adapter | |
RIO/HSL adapter
|
SIIOADP |
Un-P1-C05 | Yes | RIO/HSL card | |
PCI adapter in slot 6 | PIOCARD |
Un-P1-C06 | Yes | PCI adapter | |
PCI adapter in slot 7 | PIOCARD |
Un-P1-C07 | Yes | PCI adapter | |
PCI adapter in slot 8 | PIOCARD |
Un-P1-C08 | Yes | PCI adapter | |
PCI bridge set 1 | BRDGSET |
Un-P1 |
Replace the system backplane and cards using the removal and replacement procedures corresponding to the locations indicated. | ||
PCI bridge set 2 | BRDGSET |
Un-P1 |
Replace the system backplane and cards using the removal and replacement procedures corresponding to the locations indicated. | ||
EPO connector (J11) | Un-P1-T1 | ||||
UPS connector (J14) | Un-P1-T2 | ||||
SPCN connector (J15) | Un-P1-T3 | ||||
SPCN connector (J16) | Un-P1-T4 | ||||
Rack beacon connector | Un-P1-T5 | ||||
Fan 1 | Un-A1 | Yes | Part assembly diagrams | Fan | |
Fan 2 | Un-A2 | Yes | Part assembly diagrams | Fan | |
Fan 3 | Un-A3 | Yes | Part assembly diagrams | Fan | |
Fan 4 | Un-A4 | Yes | Part assembly diagrams | Fan | |
Device physical locations | |||||
Disk drive 1 | Un-DB1-D01 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 2 | Un-DB1-D02 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 3 | Un-DB1-D03 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 4 | Un-DB1-D04 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 5 | Un-DB1-D05 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 6 | Un-DB1-D06 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 7 | Un-DB2-D07 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 8 | Un-DB2-D08 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 9 | Un-DB2-D09 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 10 | Un-DB2-D10 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 11 | Un-DB2-D11 (logical location not applicable) | Disk unit parts | Disk drive | ||
Disk drive 12 | Un-DB2-D12 (logical location not applicable) | Disk unit parts | Disk drive | ||
Power supply 1 | Un-E1 | Power parts | Power supply | ||
Power supply 2 | Un-E2 | Power parts | Power supply | ||
Disk drive backplane | Un-DB1 | Backplanes | Disk drive backplane | ||
Disk drive backplane | Un-DB2 | Backplanes | Disk drive backplane | ||
RIO/HSL adapter connector (bottom connector) | HSL_LNK |
Un-P1-C05-00 or Un-P1-C05-T1 | Yes | Exchanging RIO/HSL cables | |
RIO/HSL adapter connector | HSL_LNK |
Un-P1-C05-01 or Un-P1-C05-T2 | Yes | Exchanging RIO/HSL cables |
Multi-adapter bridge domain / PCI bridge set | IOA assignment rules |
---|---|
C01 - C04 | C01, C02, C03, C04 |
C06 - C08 | C06, C07, C08 |