PCIe adapter placement rules and slot priorities for the 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A
Find information about the placement rules and slot priorities for the Peripheral Component Interconnect (PCI) Express (PCIe) adapters that are supported for the 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A system.
PCIe slot descriptions for the 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A
Slot | Adapter size | Slot availability in | ||||
---|---|---|---|---|---|---|
8247-21L and 5148-21L | 8247-22L and 5148-22L | 8284-21A 1 processor |
8284-22A 1 processor |
8284-22A 2 processors |
||
PCIe3, x16 | Low-profile | 2 slots (P1-C6 and P1-C7) |
4 slots (P1-C3®, P1-C5, P1-C6, and P1-C7) |
2 slots (P1-C6 and P1-C7) |
2 slots (P1-C6 and P1-C7) |
4 slots (P1-C3, P1-C5, P1-C6, and P1-C7) |
PCIe3, x8 | Low-profile | 3 slots (P1-C91, P1-C11, and P1-C12) |
4 slots (P1-C2, P1-C91, P1-C11, and P1-C12) |
4 slots (P1-C91, P1-C10, P1-C11, and P1-C12) |
3 slots (P1-C91, P1-C11, and P1-C12) |
4 slots (P1-C2, P1-C91, P1-C11, and P1-C12) |
1The slot is not available to install other adapters in the expanded function system backplane. |
- PCIe slots
- Embedded PCIe local area network (LAN) controller
- PCIe3 internal SAS controller
- PCIe3 USB controller
- PCIe3 Switch 1 that provides PCIe buses from Processor Module 1, Chip-0.
- PCIe3 Switch 2 that provides PCIe buses from Processor Module 1, Chip-1.
Features provided | PCIe3 Switch 1 | PCIe3 Switch 2 |
---|---|---|
Lanes and ports | 32-lane, 8-ports PCIe Gen3 | 48-lane, 12-ports PCIe Gen3 |
With integrated 8.0 gigatransfers per second (GTps) Serializer/Deserializer (SerDes) speed negotiation, for each port | ||
Lane and polarity reversal | Supported | Supported |
All ports support concurrent maintenance through I2C bus | Yes | Yes |
End-to-end cyclic redundancy check (CRC) and Poison bit error checking | Supported | Supported |
Data path parity | Supported | Supported |
Memory error correction | Supported | Supported |
Advanced error reporting | Supported | Supported |
Aggregate full duplex bandwidth | 512 GT/s | 768 GT/s |
Designate any port as the Upstream port | Yes | Yes |
27x27 mm, 676-pin FCBGA package | Yes | Yes |
Power consumption |
|
|
Figure 1 shows the rear view of the system with the location codes for the PCIe adapter slots.
Table 3 lists the PCIe adapter slot locations and details for the 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A system.
Slot | Location code |
Description | PHB | Adapter size |
Slot capabilities | Slot availability in | ||||
---|---|---|---|---|---|---|---|---|---|---|
CAPI | SR-IOV | Dynamic direct memory access (DMA) window | I/O adapter enlarged capacity assign order5 | 8247-21L, 8284-21A,
8284-22A, or 5148-21L 1 processor |
8247-22L, 8284-22A, or 5148-22L
2 processors |
|||||
Slot 1 | P1-C21, 6 | PCIe3, x8 | Processor Module 2, Chip-1, PHB1 | Low-profile | No | Yes | Yes | 5 | No | Yes |
Slot 2 | P1-C31 | PCIe3, x16 | Processor Module 2, Chip-1, PHB0 | Low-profile | Yes | Yes | Yes | 9 | No | Yes |
Slot 3 | P1-C41, 6 | PCIe3, x8 | Processor Module 2, Chip-0, PHB1 | N/A | N/A | N/A | N/A | N/A | No | No |
Slot 4 | P1-C51 | PCIe3, x16 | Processor Module 2, Chip-0, PHB0 | Low-profile | Yes | Yes | Yes | 11 | No | Yes |
Slot 5 | P1-C61 | PCIe3, x16 | Processor Module 1, Chip-1, PHB0 | Low-profile | Yes | Yes | Yes | Default | Yes | Yes |
Slot 6 | P1-C71 | PCIe3, x16 | Processor Module 1, Chip-0, PHB0 | Low-profile | Yes | Yes | Yes | Default | Yes | Yes |
Slot 7 | P1-C82 | PCIe3, x8 | PCIe3 Switch 2, S2P16 | N/A | N/A | N/A | N/A | N/A | No | No |
Slot 8 | P1-C92, 3 | PCIe3, x8 | PCIe3 Switch 2, S2P17 | Low-profile | No | No | Yes | 6, 84 | Yes | Yes |
Slot 9 | P1-C102, 6 | PCIe3, x8 | PCIe3 Switch 2, S1P9 | Low-profile | No | Yes | Yes | Default | Dedicated slot for the LAN adapter | |
Slot 10 | P1-C112 | PCIe3, x8 | PCIe3 Switch 1, S0P1 | Low-profile | No | No | Yes | 7 | Yes | Yes |
Slot 11 | P1-C122, 6 | PCIe3, x8 | PCIe3 Switch 1, S1P9 | Low-profile | No | Yes | Yes | Default | Yes | Yes |
1Slot is a direct slot from the Processor Module and is a high-performance slot. The connectors in these slots are differently colored than the slots from the PCIe3 switches. 2Slot connected by the PCIe3 switches. 3Slot is not available to install other adapters in the expanded function system backplane. 4The I/O Adapter Enlarged Capacity assignment order value is 6 for one processor or 8 for two processors. 5Assigned PCIe slot order when the I/O Adapter Enlarged Capacity option is enabled.
For example, if the option was enabled with a value of 5 on a two processor system, five slots
(P1-C6, P1-C7, P1-C10, P1-C12, and P1-C2) are enabled with the I/O enlarged capacity. If the option
was enabled with a value of 7 on a two processor system, then six slots (P1-C6, P1-C7, P1-C10,
P1-C12, P1-C2, and P1-C11) are enabled with the I/O enlarged capacity, and so on.
Note: Enabling the I/O Adapter Enlarged Capacity option will only affect Linux partitions. If your system does not have Linux partitions, the I/O Adapter Enlarged Capacity setting should be disabled.
6For platforms with less than 64GB of total system memory, SR-IOV should not be configured in these slots as performance may be severely impacted.
|
PCIe adapters placement rules
- The slot P1-C10 must be used to install the local area network (LAN) adapter feature codes (FCs) EN0T, EN0V, or EN0X. Any other PCIe adapter feature is not supported in this slot.
- The PCIe3 cable adapter (FC EJ05) is supported in
slots P1-C3, P1-C6, and P1-C7. Note: This is a double-wide adapter that requires two adjacent slots.
- CAPI accelerator adapters are supported in slots P1-C6, P1-C7, P1-C3, and P1-C5.
- Slots P1-C3, P1-C5, P1-C6, and P1-C7 are x16 slots with busses direct from the Processor Modules and can be used to install high-performance PCIe adapters. The adapter priority for these slots is for CAPI accelerator adapters (for example, EJ16), PCI accelerator adapters (for example, EJ13), and then for the high-performance adapters, followed by any other adapter.
- Slots P1-C2 is an x8 slot with bus direct from the Processor Modules and can be used to install high-performance PCIe adapters. The adapter priority for this slot is for the high-performance adapters followed by any other adapter.
- Slots P1-C2, P1-C3, P1-C5, P1-C6, and P1-C7 are slots with busses direct from the Processor Modules and are recommended for high-performance PCIe adapters that support the Single Root IO Virtualization (SR-IOV) function.
- FCs 5901, 5278, 5284, and 5287 are not supported in the slots P1-C8, P1-C9, P1-C10, P1-C11, and P1-C12.
- PCIe internal slots P1-C14 and P1-C15 are used to install the SAS RAID adapter FC EJ0V or EL3V and the high-performance internal SAS RAID adapter (CCIN 57D8).
- When the high-performance internal SAS RAID adapter (CCIN 57D8) is installed, the FC EJ0Z is installed in PCIe slot P1-C9 and slot P1-C9 is not available for installing any other PCIe adapter. Slot P1-C9 is used to install the two external SAS ports.
Verify whether the adapter is supported for your system. For details about the supported adapters, see PCIe adapter information by feature types for the 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A.
Feature code | Description | 8247-21L or 5148-21L | 8247-22L or 5148-22L | 8284-21A 1 processor |
8284-22A 1 processor |
8284-22A 2 processors |
|||||
---|---|---|---|---|---|---|---|---|---|---|---|
Slot priorities | Maximum number of adapters supported | Slot priorities | Maximum number of adapters supported | Slot priorities | Maximum number of adapters supported | Slot priorities | Maximum number of adapters supported | Slot priorities | Maximum number of adapters supported | ||
5260 | PCIe2
LP 4-port 1 GbE Adapter (FC 5260; CCIN 576F); Adapter FRU number:
74Y4064
OS support: AIX,
IBM i, Linux, PowerKVM, and VIOS operating systems
|
11, 10, 82, 6, 5 | 6 | 11, 2, 10, 82, 6, 4, 5 | 7 | 11, 10, 82, 6, 5 | 6 | 11, 10, 82, 6, 5 | 6 | 11, 2, 10, 82, 6, 4, 5 | 8 |
5269 | POWER® GXT145 PCI Express Graphics Accelerator
(FC 5269; CCIN 5269); Adapter FRU number: 74Y3227
OS support: Linux operating system |
10, 82, 5, 6 | 4 | 10, 82, 1, 2, 4, 5, 6 | 7 | 10, 82, 5, 6 | 4 | 10, 82, 5, 6 | 4 | 10, 82, 1, 2, 4, 5, 6 | 7 |
5270 | 10 Gb
FCoE PCIe Dual-port Adapter (FC 5270; CCIN 2B3B); Adapter FRU number:
46K8088
OS support (depending on the system you
are using):
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
5271 | 4-port
10/100/1000 Base-TX PCI Express Adapter
(FC 5271; CCIN 5717); Adapter FRU number: 46Y3512
OS support (depending on the system you
are using):
|
11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 | Not supported | Not supported | 11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 |
5273 | PCIe2
8 Gb Dual-port Fibre Channel Adapter (FC 5273; CCIN 577D); Adapter
FRU number: 10N9824
OS support (depending on the system you
are using):
|
Not supported | Not supported | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
5274 | 2-port
Gb Ethernet-SX PCI Express Adapter
(FC 5274; CCIN 5768); Adapter FRU number: 10N6846
OS support (depending on the system you
are using):
|
11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 | Not supported | Not supported | 11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 |
5275 | 10 Gb
Ethernet-SR PCI Express Adapter
(FC 5275; CCIN 5275); Adapter FRU number: 46K7897
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
5276 | 4-Gb PCI Express Dual-port Fibre Channel
Adapter (FC 5276; CCIN 5774); Adapter FRU number: 10N7255
OS support: Linux operating system |
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
5277 | 4-port
Async EIA-232 PCIe 1X LP Adapter (FC 5277; CCIN 57D2); adapter FRU
number 46K6734
OS support: Linux operating system |
10, 82, 5, 6 | 4 | 10, 82, 1, 2, 4, 5, 6 | 7 | 10, 82, 5, 6 | 4 | 10, 82, 5, 6 | 4 | 10, 82, 1, 2, 4, 5, 6 | 7 |
52783 | PCIe
Dual-x4 SAS Adapter (FC 5278; CCIN 57B3); Adapter FRU number: 44V4852
OS support: Linux operating system |
Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | 5, 6 | 2 | 5, 2, 6, 4 | 4 |
5280 | PCIe2
LP 2x10 GbE SR 2x1 GbE UTP Adapter (FC 5280; CCIN 2B54); Adapter FRU
number 74Y1988
OS support: Linux operating system |
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
5281 | 1 Gb
Ethernet UTP 2-port PCIe Adapter (FC 5281; CCIN 5767); Adapter FRU
number: 46K6601
OS support: Linux operating system |
11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 | Not supported | Not supported | 11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 |
5283 | PCIe2
LP 2-port 4X InfiniBand QDR Adapter (FC 5283; CCIN 58E2); Adapter
FRU number: 74Y2987
OS support: Linux operating system |
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
52843 | PCIe2
LP 2-port 10 GbE SR Adapter (FC 5284; CCIN 5287); Adapter FRU number:
74Y3242
|
Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | 5, 6 | 2 | 5, 2, 6, 4 | 2 |
EC27 | PCIe2
LP 2-port 10 GbE RoCE SFP+ adapter (FC EC27; CCIN EC27); Adapter FRU
number: 000E1493
|
Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EC29 | PCIe2
LP 2-port 10 GbE RoCE SR adapter (FC EC29; CCIN EC29); Adapter FRU
number: 00E1600
|
Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EC2G | PCIe
LP 2-Port 10 GbE SFN6122F Adapter (FC EC2G; CCIN EC2G); Adapter FRU
number: 00E8224
|
Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EC2M4 | PCIe3
LP 2-port 10 GbE NIC and RoCE SR adapter (FC EC2M; CCIN 57BE); Adapter
FRU number: 00RX875, low-profile tailstock: 00RX872
|
Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EC3A | PCIe3 LP 2-Port 40 GbE NIC RoCE QSFP+ Adapter
(FC EC3A; CCIN 57BD); Adapter FRU number: 00FW105
OS support (depending on the system you are using): AIX, Linux, and VIOS supports NIC capability only |
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EC3E | PCIe3 2-port 100 Gb EDR IB Adapter x16 (FC
EC3E and EC3F; CCIN 2CEA); Adapter FRU number:
00WT075
|
5, 6 | 2 | 5, 2, 6, 4 | 4 | Not supported | Not supported | 5, 6 | 2 | 4, 6, 2, 5 | 4 |
EC3L | PCIe3
2-port 100 GbE (NIC and RoCE) QSFP28 Adapter (FC EC3L and EC3M; CCIN 2CEC); Adapter FRU
number: 00WT078
|
5, 6 | 2 | 5, 2, 6, 4 | 4 | Not supported | Not supported | 5, 6 | 2 | 4, 6, 2, 5 | 4 |
EC3T | PCIe3 LP
1-port 100 Gb EDR InfiniBand Adapter x16 (FC EC3T; CCIN 2CEB) Adapter FRU number: 00WT013
|
5, 6 | 2 | 5, 2, 6, 4 | 4 | Not supported | Not supported | 5, 6 | 2 | 4, 6, 2, 5 | 4 |
EC374 | PCIe3 LP 2-port 10 GbE
NIC and RoCE SFP+ Copper Adapter (FC EC37; CCIN 57BC); Adapter
FRU number: 00RX859
|
Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EC41 | PCIe2
LP 3D Graphics Adapter x1 (FC EC41); Adapter FRU number: 00E3980
|
11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 | Not supported | Not supported | 11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 |
EC45 | PCIe2
LP 4-port USB 3.0 Adapter (FC EC45; CCIN 58F9); Adapter FRU number:
00E2932; low-profile tailstock part number: 00E2934
|
11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 | 11, 10, 82, 5, 6 | 5 | 11, 10, 82, 5, 6 | 5 | 11 , 1, 10, 82, 2, 6, 4, 5 | 8 |
EC51 | PCIe2 LP 3D Graphics Adapter x16 (FC EC51)
|
5, 6 | 2 | 2, 4, 5, 6 | 4 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EC54 | PCIe3 1.6 TB NVMe Flash Adapter (FC EC54 and EC55; CCIN
58CB); Adapter FRU number: 00MH991
|
5, 6, 102, 86, 11 | 5 | 1, 2, 4, 5, 6, 86, 10 | 7 | Not supported | Not supported | 5, 6, 102, 86, 11 | 5 | 1, 2, 4, 5, 6, 86, 10 | 7 |
EC54 | PCIe3 1.6 TB NVMe Flash Adapter (FC EC54 and EC55; CCIN
58CB); Adapter FRU number: 00MH991
|
5, 6, 102, 86, 11 | 5 | 1, 2, 4, 5, 6, 86, 10 | 7 | Not supported | Not supported | 5, 6, 102, 86, 11 | 5 | 1, 2, 4, 5, 6, 86, 10 | 7 |
EC56 | PCIe3 3.2 TB NVMe Flash Adapter
(FC EC56 and EC57; CCIN 58CC); Adapter FRU number: 00MH993
|
5, 6, 102, 86, 11 | 5 | 1, 2, 4, 5, 6, 86, 10 | 7 | Not supported | Not supported | 5, 6, 102, 86, 11 | 5 | 1, 2, 4, 5, 6, 86, 10 | 7 |
EJ05 | PCIe3 cable adapter for
the EMX0 PCIe Gen3 I/O expansion drawer (FC
EJ05; CCIN 2B1C); Adapter FRU number: 000RR809
|
5-6, 6-7 | 1 | 2-3, 5-6, 6-7 | 2 | Not supported | Not supported | 5-6, 6-7 | 1 | 2-3, 5-6, 6-7 | 2 |
EJ0M | PCIe3
RAID SAS quad-port 6 Gb LP Adapter (FC EJ0M; CCIN 57B4); Adapter FRU
number: 000MH910
|
Not supported | Not supported | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EJ11 | PCIe3
LP 4 x8 SAS Port Adapter (FC EJ11; CCIN 57B4); Adapter FRU number:
000MH910
|
Not supported | Not supported | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EJ135 | PCIe3 LP FPGA Compression
Accelerator Adapter (FC EJ13; CCIN 59AB); Adapter FRU number: 000NK006
|
5, 6 | 2 | 1, 5, 2, 6, 4 | 4 | Not supported | Not supported | 5, 6 | 2 | 1, 5, 2, 6, 4 | 4 |
EJ165 | PCIe3 LP CAPI Fibre Channel Flash Accelerator
Adapter (FC EJ16); Adapter FRU number: 00NK025
|
5, 6 | 1 | 5, 2, 6, 4 | 2 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EJ185 | PCIe3 LP CAPI FlashSystem
Accelerator Adapter (FC EJ18); Adapter FRU number: 00NK025
|
Not supported | Not supported | Not supported | Not supported | 5, 6 | 1 | 5, 6 | 1 | 5, 2, 6, 4 | 2 |
EJ1B | CAPI Compression Accelerator Adapter (FC EJ1A and EJ1B; CCIN
2CF0); Adapter FRU number: 00WT173
|
4, 5 | 1 | 2, 4, 5, 6 | 2 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EJ1N | PCIe1 SAS Tape/DVD Dual-port 3 Gb x8 Adapter (FC EJ1P and
EJ1N; CCIN 57B3); Adapter FRU:44V4852
|
5, 6 | 2 | 5, 2, 6, 4 | 4 | Not supported | Not supported | 5, 6 | 2 | 4, 6, 2, 5 | 4 |
EJ32 | 4767-001 Cryptographic Coprocessor (FC EJ32 and EJ33; CCIN
4767)
|
Not supported | 6 | Not supported | 10 | Not supported | Not supported | Not supported | 6 | Not supported | 10 |
EJ1K | PCIe3 1.92 TB CAPI NVMe Flash
Accelerator Adapter (FC EJ1K; CCIN 58CD)
|
5, 6 | 2 | 2, 5, 4, 6 | 4 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL09 | PCIe
LP 4 Gb 2-port Fibre Channel Adapter (FC EL09; CCIN 5774); adapter
FRU number: 000E0807, 000E0904
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL103 | PCIe
LP 2-port SAS Adapter 3 Gb (FC EL10; CCIN 57B3); Adapter FRU number:
44V4852
|
5, 6 | 2 | 5, 2, 6, 4 | 4 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL27 | PCIe2
2-port 10 GbE RoCE SFP+ adapter (FC EL27; CCIN EC27); Adapter FRU
number: 74Y1988
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL2N | PCIe
8 Gb Dual-port Fibre Channel Adapter (FC EL2N; CCIN 577D); Adapter
FRU number: 10N9824
OS support: Linux and PowerKVM operating systems |
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL2P3 | PCIe2
LP 2-port 10 GbE SR Adapter (FC EL2P; CCIN 5287); Adapter FRU number:
74Y3242
|
5, 6 | 2 | 5, 2, 6, 4 | 4 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL2Z | PCIe2
LP 2-port 10 GbE RoCE SR adapter (FC EL2Z; CCIN EC29); Adapter FRU
number: 00E1600
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL38 | PCIe3 LP 4-port (10 Gb FCoE, 1 GbE) SFP+ Adapter (FC EL38,
CCIN 2B93); Adapter FRU number: 000E9284
|
5, 6, 9, 11 | 5 | 5, 2, 6, 4, 1, 9, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL39 | PCIe
LP 2-Port 10 GbE SFN6122F Adapter (FC EL39; CCIN EC2G); Adapter FRU
number: 00E8224
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL3B | PCIe3
LP RAID SAS Adapter (FC EL3B; CCIN 57B4); Adapter FRU number: 000MH910
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL3C | PCIe3 LP 4-port (10 Gb FCoE and 1 GbE) Copper and RJ45
Adapter (FC EL3C; CCIN 2CC1); Adapter FRU number: 00E8140
|
5, 6, 9, 11 | 5 | 5, 2, 6, 4, 1, 9, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL3D | PCIe3 LP 2-port 56 Gb
FDR IB Adapter x16 (FC EL3D; CCIN 2CE7); Adapter FRU number: 00RX852
|
5, 6 | 2 | 5, 2, 6, 4 | 4 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL3X | PCIe3 LP 2-port 10 GbE NIC and RoCE SFP+ Copper Adapter (FC
EL3X; CCIN 57BC); Adapter FRU number: 0RX859; Low-profile tailstock: 00RX856
|
5, 6, 8, 10, 11 | 5 | 5, 2, 6, 4, 1, 8, 10, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL3Z | PCIe2 LP 2-port 10 GbE BaseT RJ45 Adapter (FC EL3Z; CCIN
2CC4); Adapter FRU number: 00E2714; Full-height tailstock part number: 00E2862; Low-profile
tailstock part number: 00E2721
OS support: Linux and PowerKVM operating systems |
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL40 | PCIe3 LP 2-port 10 GbE
NIC and RoCE SR Adapter (FC EL40; CCIN 57BE); Adapter FRU
number: 00RX875
|
5, 6, 8, 10, 11 | 5 | 5, 2, 6, 4, 1, 8, 10, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL43 | PCIe3 LP 16 Gb 2-port
Fibre Channel Adapter (FC EL43; CCIN 577F); Adapter FRU
number: 00E3496
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EL4M | PCIe2 4-port 1 GbE Adapter
(FC EL4L and EL4M; CCIN 576F); Adapter FRU number: 74Y4064
e
|
11, 10, 82, 6, 5 | 6 | 11, 1, 10, 82, 6, 4, 5 | 7 | Not supported | Not supported | 11, 10, 82, 6, 5 | 8 | Not supported | Not supported |
EL60 | PCIe3
LP 4 x8 SAS Port Adapter (FC EJ60; CCIN 57B4); Adapter FRU number:
000MH910
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
EL5Y | PCIe2 8 Gb 2-Port Fibre Channel Adapter (FC EL5Y and EL5Z;
CCIN 578D); Adapter FRU number: 00WT111
|
5, 6, 8, 10, 11 | 5 | 5, 2, 6, 4, 1, 8, 10, 11 | 8 | Not supported | Not supported | 5, 6, 8, 10, 11 | 5 | 5, 2, 6, 4, 1, 8, 10, 11 | 8 |
EN0B | PCIe3 LP 16
Gb 2-port Fibre Channel Adapter (FC EN0B; CCIN 577F); Adapter FRU number: 000E9283
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | 5, 6, 82, 10, 11 | 5 | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EN0F | PCIe2 8Gb 2-Port Fibre Channel
Adapter (FC EN0F and EN0G; CCIN 578D); Adapter FRU number: 00WT111
|
5, 6, 8, 10, 11 | 5 | 5, 2, 6, 4, 1, 8, 10, 11 | 8 | 5, 6, 8, 10, 11 | 5 | 5, 6, 8, 10, 11 | 5 | 5, 2, 6, 4, 1, 8, 10, 11 | 8 |
EN0J | PCIe3 LP
4-port (2x10 Gb FCoE, 2x1 GbE) SFP+ Adapter (FC EN0J, CCIN 2B93); Adapter FRU number: 00E3498
|
Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | 5, 6, 9, 11 | 5 | 5, 2, 6, 4, 1, 9, 11 | 8 |
EN0L | PCIe3 LP
4-port (10 Gb FCoE and 1 GbE) Copper and RJ45 Adapter (FC EN0L; CCIN 2CC1)Adapter FRU
number: 00E3502
|
Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | 5, 6, 9, 11 | 5 | 5, 2, 6, 4, 1, 9, 11 | 8 |
EN0N | PCIe3 LP 4-port (10 Gb FCoE and 1 GbE) LR and RJ45 Adapter
(FC EN0N; CCIN 2CC0); Adapter FRU number: 00E8143; low-profile tailstock part number: 00E8163
|
5, 6, 9, 11 | 5 | 5, 2, 6, 4, 1, 9, 11 | 8 | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EN0T | PCIe2
LP 4-port (10 Gb + 1 GbE) SR+RJ45 Adapter (FC EN0T; CCIN 2CC3); Adapter
FRU number: 00E2715; Low-profile tailstock (PN): 00E2720
OS support: Linux and PowerKVM operating systems |
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | 5, 6, 82, 10, 11 | 5 | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EN0V | PCIe2 LP 4-port (10
Gb + 1 GbE) Copper SFP+RJ45 Adapter (FC EN0V; CCIN 2CC3);
Adapter FRU number: 00E2715; low-profile
tailstock: 00E2720
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | 5, 6, 82, 10, 11 | 5 | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EN0X | PCIe2
LP 2-port 10 GbE BaseT RJ45 Adapter (FC EN0X; CCIN 2CC4); Adapter
FRU number: 00E2714; low-profile tailstock part number: 00E2721
|
Not supported | Not supported | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EN0Y | PCIe2
LP 8 Gb 4-port Fibre Channel Adapter (FC EN0Y; CCIN EN0Y); Adapter
FRU number: 74Y3923
|
5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 | Not supported | Not supported | 5, 6, 82, 10, 11 | 5 | 5, 2, 6, 4, 1, 82, 10, 11 | 8 |
EN28 | PCIe 2-port Async EIA-232 LP Adapter (FC EN28; CCIN 57D4);
Adapter FRU number 000ND487
|
11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 | Not supported | Not supported | 11, 10, 82, 6, 5 | 5 | 11, 1, 10, 82, 2, 6, 4, 5 | 8 |
1The adapters are installed in this order in the system for best performance. 2The slot is not available to install other adapters in the expanded function system backplane. 3The adapters FCs 5278, 5284, EL10, and EL2P are not supported in slots 7, 8, 9, 10, and 11. 4The adapters FCs EC37 and EC2M are not supported in the 8284-22A system with processor card FCs EPXL and ELPF. 5The adapters FC EJ16, EJ17, and EJ18 are not compatible with the adapters FC EJ12 and EJ13. The FC EJ12 and EJ13 adapters are for gzip compression offload, and the FC EJ16, EJ17 and EJ18 are for direct-attach fibre channel flash acceleration. 6The slot is not available when the High Function RAID controller FC EJ0U is also installed. |