Rack feature codes
The rack feature codes for the EH7, EH8, 55F, 60F and 70F tape drives.
- FC 4804: Rack Mount Kit
- This feature provides a Rack Mount Kit to accept up to two 3592 EH7, EH8, 55F, 60F
or 70F tape drives. It includes the enclosure hardware and also provides two redundant
power supplies and two C13-C14 power cords.
Corequisite: If only 9806 and no 9807 are resident for 4804 Rack Mount Kit, a 4806 drive filler panel is required.
Prerequisite: FC 9806.
Maximum: one. Plant or field installation.
In any specified rack, the following aggregate maximums apply:- For 2 m (6.6 ft.) racks: 14
- For 1.8 m (5.9 ft.) racks: 12
- For 1.6 m (5.25 ft.) racks: 10
- FC 4805: Rack Drive Accessories
- This feature provides documentation and miscellaneous items. It includes the Rack Mount Kit
installation instructions, drive maintenance manuals, one JC Data cartridge, one cleaning and one CE
Diagnostic cartridge, and an Ethernet cable for service.
Prerequisite: FC 9806 or 9807.
Maximum: one. Plant or field installation. eConfig limits this feature to one per customer rack.
. - FC 4806: Drive Filler Panel
- This feature provides a blank filler panel. Required when only one drive resides in an FC 4804
Rack Mount kit enclosure.
Prerequisite: FC 4804.
Maximum: two. Plant or field installation.
- FC 9806: Install First Drive in Rack Mount Kit
- This feature adds an EH7, EH8, 55F, 60F
or 70F tape drive to the left-side of an FC 4804 Rack Mount Kit enclosure. Tape drives are
not installed into the Rack Mount Kit; they are shipped
separately.
Prerequisite: Must have FC 4804.
Maximum: one. Plant or field installation.
- FC 9807: Install Second Drive in Rack Mount Kit
- This feature adds an EH7, EH8, 55F, 60F
or 70F tape drive to the right-side of an FC 4804 Rack Mount Kit enclosure. Tape drives are
not installed into the Rack Mount Kit; they are shipped
separately.
Prerequisite: Mutually exclusive with FC 4804.
Maximum: one. Plant or field installation.
- FC 9905: Hardcopy Support Documentation
- This feature directs the plant to ship product support documentation in hardcopy
format.
Prerequisite: Must have Feature FC 9806 or FC9807
Maximum: one. Plant installation.
Customer setup: Yes
- RPQ 8B3658: Rack Mount Drive Filter Assembly
- This feature provides a rack mount kit bezel that accepts two 80-mm air filters. The Filter
Assembly includes two screws and nutclips. The filters are ordered by the customer and can be
purchased online at most computer supply companies.
Prerequisite: Must have FC 4804.
Maximum: one. Plant or field installation.