00E30013

Explanation

The value specified in the DSN6SYSP CSECT to define reserve storage is either negative or zero.

System action

Db2 is terminated.

Operator response

Notify the system programmer.

System programmer response

Reassemble DSN6SPRM and relink-edit the DSNZPARM load module. This is done by resubmitting the installation job stream, DSNTIJUZ, that built the load module named in the -START DB2 command 'PARM=' parameter.

Problem determination

Collect the following diagnostic items:
  • Console output from the system on which the job was run, and a listing of the SYSLOG data set for the period of time that spans the failure.
  • Dynamic dump, taken to SYS1.DUMPxx data set, by Db2 (04E and 04F abends).
  • SVC dump (or system dump), taken to SYS1.DUMPxx data set, as result of an operator-initiated dump command or SLIP trap exit.
  • A listing of the SYS1.LOGREC data set, obtained by executing IFCEREP1.
  • Listing of DSNZPARM module used.