DYNAM
Use DYNAM
to
cause nonnested, separately
compiled programs invoked through the CALL
literal statement
to be loaded for CALL
, and deleted for CANCEL
,
dynamically at run time.
Note: The
DYNAM
option
can be overridden for particular CALL
statements
by using the CALLINTERFACE
directive.CALL
identifier statements
always result in a runtime load of the target program and are not
affected by this option.
Default is: NODYNAM
Abbreviations
are: DYN
|NODYN
Restriction: The
DYNAM
compiler
option must not be used in the following cases: - COBOL programs that are processed by the CICS® translator or the
CICS
compiler option - COBOL programs that have
EXEC SQL
statements and are run under CICS or DB2® call attach facility (CAF)
If your COBOL program calls programs
that have been linked as dynamic link libraries (DLLs), you must not
use the DYNAM
option. You must instead compile the
program with the NODYNAM
and DLL
options.
related references
Conflicting compiler options
CALLINTERFACE (Enterprise COBOL for z/OS® Language Reference)
Conflicting compiler options
CALLINTERFACE (Enterprise COBOL for z/OS® Language Reference)