Installing an adapter in the 9040-MR9 system
To install an adapter in the system, complete the steps in this procedure.
Procedure
- Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface. If not, do so now.
-
If necessary, remove the adapter from the antistatic package.
Attention: Avoid touching the components and gold connectors on the adapter.
-
Place the adapter, component-side up, on a flat, antistatic
surface.
Attention: A pin on the tailstock of the adapter resembles a removable screw. Do not remove this pin. It is required for correct alignment and seating.
-
Remove the cassette from the slot:
-
Squeeze the latch lever (A) and press down on the latch
(B) in the direction shown.
This action pivots the cassette forward and releases the cassette from the slot.
-
Pull out the cassette from its slot.
-
Squeeze the latch lever (A) and press down on the latch
(B) in the direction shown.
-
Remove the tailstock filler from the cassette.
- Open the tailstock clamp (A) by rotating the clamp in the direction that is shown.
- Press and slide the release bar (B) in the direction that is shown to open the cassette.
-
Grasp the tailstock filler and pull the filler away from the cassette in the direction that is
shown.
Note: Your cassette might not have the two adapter retainers (C) and strips.
-
Save the tailstock filler for a future use.
You must have a tailstock filler in an empty cassette in a system to ensure proper airflow.
- Choose from the following options:
-
If your cassette has two adapter retainers with strips, complete the following steps to install
or replace an adapter into the cassette:
- If the adapter retainers (A) haven't already been removed, remove the adapter retainers (A) by putting them in the open position and moving them all the way off the strips.
- Press and slide the release bar (B) to open the cassette.
-
Place an ESD safety sheet (C) over the strips.
Note: You can use the ESD package that the new adapter was in. If necessary, cut it to size.
- Insert the adapter into the cassette.
- Press and slide the release bar (A) to close the cassette.
- Close the tailstock clamp (B) by rotating the clamp in the direction that is shown.
-
Pull the ESD safety film (C) out.
- With the adapter retainers (D) in the open position, slide the retainers onto the strips.
-
Position the adapter retainers (D) so that they support the adapter and
put them in the locked position by rotating them in the direction that is shown.
Note: Ensure that the adapter is secured in the adapter retainer channel.
-
If your cassette does not have the two adapter retainers and strips, complete the following
steps to install or replace an adapter into the cassette:
- Press and slide the release bar (A) to open the cassette.
- Insert the adapter into the cassette.
- Press and slide the release bar (A) to close the cassette.
-
Close the tailstock clamp (B) by rotating the clamp in the direction
that is shown.
-
Slide the cassette into the slot by completing the following steps:
Attention:
Ensure proper alignment when you insert an adapter cassette into the system.
- Align the cassette on the cassette rail in the cassette slot.
- Slide the cassette forward until the cassette is fully seated.
-
To lock the cassette in its slot, squeeze the latch lever (A) toward the
latch (B) and rotate the latch (B) in the direction
that is shown.