8247-42L, 8286-41A, or 8286-42A locations
Use this information to help you map a location
code to a position on the unit.
The following diagrams show field-replaceable unit (FRU) layouts in the system. Use these diagrams with the following tables.
Rack views
The following graphics represent location codes for 8247-42L or 8286-42A. The 8286-41A has the same location codes, but only a subset of the locations support hardware. The asterisk (*) in the FRU location table indicates locations that are not supported for 8286-41A.Figure 1. Rack front view (base function)![Rack front view (base function)](p8ecs600.gif)
![Rack front view (base function)](p8ecs600.gif)
Figure 2. Rack front view (expanded function)![Rack front view (expanded function)](p8ecs610.gif)
![Rack front view (expanded function)](p8ecs610.gif)
Figure 3. Rack top view (base function)![Rack top view (base function)](p8ecs601.gif)
![Rack top view (base function)](p8ecs601.gif)
Figure 4. Rack top view (expanded function)![Rack top view (expanded function)](p8ecs611.gif)
![Rack top view (expanded function)](p8ecs611.gif)
Figure 5. Rack rear view (base function)![Rack rear view (base function)](p8ecs602.gif)
![Rack rear view (base function)](p8ecs602.gif)
Figure 6. Rack rear view (expanded function)![Rack rear view (expanded function)](p8ecs612.gif)
![Rack rear view (expanded function)](p8ecs612.gif)
Tower views
Figure 7. Tower front view (base function)![Tower front view (base function)](p8ecs700.gif)
![Tower front view (base function)](p8ecs700.gif)
Figure 8. Tower front view (expanded function)![Tower front view (expanded function)](p8ecs710.gif)
![Tower front view (expanded function)](p8ecs710.gif)
Figure 9. Tower side view (base function)![Tower side view (base function)](p8ecs701.gif)
![Tower side view (base function)](p8ecs701.gif)
Figure 10. Tower side view (expanded function)![Tower side view (expanded function)](p8ecs711.gif)
![Tower side view (expanded function)](p8ecs711.gif)
Figure 11. Tower rear view (base function)![Tower rear view (base function)](p8ecs702.gif)
![Tower rear view (base function)](p8ecs702.gif)
Figure 12. Tower rear view (expanded function)![Tower rear view (expanded function)](p8ecs712.gif)
![Tower rear view (expanded function)](p8ecs712.gif)
The following table provides location codes for parts that comprise the server.
Failing item name | Physical location code | Identify LED | Failing item removal and replacement procedures |
---|---|---|---|
System unit | Un | ||
Fans | |||
Fan 1 | Un-A1 | Yes | See Fans. |
Fan 2 | Un-A2 | Yes | |
Fan 3* | Un-A3 | Yes | |
Fan 4* | Un-A4 | Yes | |
Power supplies | |||
Power supply 1* | Un-E1 | Yes | See Power supply. |
Power supply 2* | Un-E2 | Yes | |
Power supply 3 | Un-E3 | Yes | |
Power supply 4 | Un-E4 | Yes | |
Backplanes | |||
System backplane Note: The service processor is part of the system backplane.
|
Un-P1 | Yes | See System backplane. |
Time-of-day battery | Un-P1-E1 | Yes | See Time-of-day battery. |
Disk drive backplane | Un-P2 | Yes | See Disk drive backplane. |
Ports | |||
USB 3.0 port 1 (rear) | Un-P1-T1 | No | |
USB 3.0 port 2 (rear) | Un-P1-T2 | No | |
Serial port | Un-P1-C1-T1 | No | |
USB 2.0 port 1 (rear) Note: This port is used only for firmware update and
uninterruptible power supply (UPS). This port is unavailable for host operating
systems.
|
Un-P1-C1-T2 | No | |
USB 2.0 port 2 (rear) Note: This port is used only for firmware update and
uninterruptible power supply (UPS). This port is unavailable for host operating
systems.
|
Un-P1-C1-T3 | No | |
HMC port 1 | Un-P1-T3 | No | |
HMC port 2 | Un-P1-T4 | No | |
USB 3.0 port 3 (front) | Un-P1-T5 | No | |
USB 3.0 port 4 (front) | Un-P1-T6 | No | |
Adapters | |||
System I/O card | Un-P1-C1 | Yes | See System I/O card. |
PCIe x8 slot 1* | Un-P1-C2 | Yes | See PCI Adapters. |
PCIe x16 slot 2* | Un-P1-C3 | Yes | |
PCIe x8 slot 3* | Un-P1-C4 | Yes | |
PCIe x16 slot 4* | Un-P1-C5 | Yes | |
PCIe x16 slot 5 | Un-P1-C6 | Yes | |
PCIe x16 slot 6 | Un-P1-C7 | Yes | |
PCIe x8 slot 7 | Un-P1-C8 | Yes | |
PCIe x8 slot 8 | Un-P1-C9 | Yes | |
PCIe x8 slot 9 | Un-P1-C10 | Yes | |
PCIe x8 slot 10 | Un-P1-C11 | Yes | |
PCIe x8 slot 11 | Un-P1-C12 | Yes | |
System VPD card | Un-P1-C13 | Yes | See Vital product data card. |
PCIe3 x8 SAS RAID internal adapter or PCIe3 x8 cache SAS RAID internal adapter | Un-P1-C14 | Yes | |
PCIe3 x8 SAS RAID internal adapter or PCIe3 x8 cache SAS RAID internal adapter | Un-P1-C15 | Yes | |
Memory modules | |||
Memory module 1 | Un-P1-C16 | Yes | See Memory modules. |
Memory module 2 | Un-P1-C17 | Yes | |
Memory module 3 | Un-P1-C18 | Yes | |
Memory module 4 | Un-P1-C19 | Yes | |
Memory module 5 | Un-P1-C20 | Yes | |
Memory module 6 | Un-P1-C21 | Yes | |
Memory module 7 | Un-P1-C22 | Yes | |
Memory module 8 | Un-P1-C23 | Yes | |
Memory module 9* | Un-P1-C24 | Yes | |
Memory module 10* | Un-P1-C25 | Yes | |
Memory module 11* | Un-P1-C26 | Yes | |
Memory module 12* | Un-P1-C27 | Yes | |
Memory module 13* | Un-P1-C28 | Yes | |
Memory module 14* | Un-P1-C29 | Yes | |
Memory module 15* | Un-P1-C30 | Yes | |
Memory module 16* | Un-P1-C31 | Yes | |
Processor and processor regulator | |||
POWER8® processor module 1 | Un-P1-C32 | Yes | See System processor module. |
POWER8 processor module 2* | Un-P1-C33 | Yes | |
Device physical locations for systems (base function) | |||
Drive 1 | Un-P2-D1 | Yes | See Disk drives or solid-state drives. |
Drive 2 | Un-P2-D2 | Yes | |
Drive 3 | Un-P2-D3 | Yes | |
Drive 4 | Un-P2-D4 | Yes | |
Drive 5 | Un-P2-D5 | Yes | |
Drive 6 | Un-P2-D6 | Yes | |
Drive 7 | Un-P2-D7 | Yes | |
Drive 8 | Un-P2-D8 | Yes | |
Drive 9 | Un-P2-D9 | Yes | |
Drive 10 | Un-P2-D10 | Yes | |
Drive 11 | Un-P2-D11 | Yes | |
Drive 12 | Un-P2-D12 | Yes | |
DVD | Un-P2-D27 | Yes | See Media devices. |
Device physical locations for systems (expanded function) | |||
Drive 1 | Un-P2-D1 | Yes | See Disk drives or solid-state drives. |
Drive 2 | Un-P2-D2 | Yes | |
Drive 3 | Un-P2-D3 | Yes | |
Drive 4 | Un-P2-D4 | Yes | |
Drive 5 | Un-P2-D5 | Yes | |
Drive 6 | Un-P2-D6 | Yes | |
Drive 7 | Un-P2-D7 | Yes | |
Drive 8 | Un-P2-D8 | Yes | |
Drive 9 | Un-P2-D9 | Yes | |
Drive 10* | Un-P2-D10 (for systems with a solid-state drive cage) | Yes | |
Drive 11* | Un-P2-D11 (for systems with a solid-state drive cage) | Yes | |
Drive 12* | Un-P2-D12 (for systems with a solid-state drive cage) | Yes | |
Drive 13* | Un-P2-D13 (for systems with a solid-state drive cage) | Yes | |
Drive 14* | Un-P2-D14 (for systems with a solid-state drive cage) | Yes | |
Drive 15* | Un-P2-D15 (for systems with a solid-state drive cage) | Yes | |
Drive 16* | Un-P2-D16 (for systems with a solid-state drive cage) | Yes | |
Drive 17* | Un-P2-D17 (for systems with a solid-state drive cage) | Yes | |
Drive 18 | Un-P2-D18 | Yes | |
Drive 19 | Un-P2-D19 | Yes | |
Drive 20 | Un-P2-D20 | Yes | |
Drive 21 | Un-P2-D21 | Yes | |
Drive 22 | Un-P2-D22 | Yes | |
Drive 23 | Un-P2-D23 | Yes | |
Drive 24 | Un-P2-D24 | Yes | |
Drive 25 | Un-P2-D25 | Yes | |
Drive 26 | Un-P2-D26 | Yes | |
DVD | Un-P2-D27 | Yes | See Media devices. |
Control panel | |||
Control panel | Un -D1 | No | See Control panel. |
*Not applicable for 8286-41A. |