| Description |
PCIe x8 Ext Dual-x4 3 Gb SAS Adapter
and Cable Card |
PCI Express x8 Planar 3 Gb SAS Adapter (Disk/Media
Backplane) |
PCIe x4 Planar 3 Gb SAS RAID Adapter |
PCIe x8 Internal 3 Gb SAS Adapter |
PCIe SAS RAID and SSD Adapter 3 Gb x8 |
PCI Express x8 Planar 3 Gb SAS RAID Adapter
(with 175 MB Cache RAID - Dual IOA Enablement Card) |
| Form factor |
Combination PCIe x8 and Cable Card |
Planar |
Planar cache enablement |
PCIe unique to IBM® PureSystems™ |
Double Wide PCIe x8 with 1 - 4 integrated
SSDs |
Planar and Enablement Card |
| Adapter failing function code LED value |
2D0B |
2D14 |
2D26 |
2D29 |
2D40 |
2D15 |
| Physical links |
8 (two mini SAS 4x connectors, one required
to connect by an external AI cable to the top mini-SAS 4x Cable Card
connector) |
8 |
8 (two 2x wide ports to shared SAS drives
and one 2x wide port to 2B4F, one physical link to DVD, and optionally
one physical link to tape drive) |
1 |
4 (one direct SAS physical link to each
integrated SSD) |
8 |
| RAID levels supported |
RAID 0, 51, 61,
10 |
RAID 0, 51, 61,
10 |
RAID 0, 5, 6, 10 |
RAID 0 |
RAID 02, 5, 6 |
RAID 0, 5, 6, 10 |
| Adding disks to an existing disk array supported
RAID levels |
RAID 5, 6 |
RAID 5, 6 |
RAID 5, 6 |
|
RAID 5, 6 |
RAID 5, 6 |
| Write cache size4 |
|
|
175 MB |
|
|
175 MB |
| Read cache size |
|
|
|
|
|
|
| Cache battery pack technology |
|
|
LiIon |
|
|
LiIon |
| Cache battery pack FFC |
|
|
2D1B |
|
|
2D19 |
| Cache battery concurrent maintenance |
No |
No |
No |
No |
No |
Yes |
| Cache data present LED |
No |
No |
Yes |
No |
No |
Yes |
| Removable cache card |
No |
No |
No |
No |
No |
No |
| Auxiliary write cache (AWC) support |
No |
No |
No |
No |
No |
No |
| High availability (HA) two system RAID |
No |
No |
Yes |
No |
No |
Yes |
| HA two system JBOD |
No |
No |
No |
No |
No |
No |
| HA single system RAID |
No |
No |
Yes |
No |
No |
Yes |
| Requires HA RAID configuration |
No |
No |
Yes |
No |
No |
Yes |
| JBOD support |
Yes |
Yes |
No |
Yes |
Yes3 |
No |
| 520-byte virtual disk support5 |
No |
No |
No |
No |
No |
No |
- 1 The write performance of RAID 5 and RAID 6 might
be poor on adapters that do not provide write cache. Consider using
an adapter that provides write cache when using RAID 5 or RAID 6 or
use solid-state drives (SSDs) where supported to improve write performance.
- 2 RAID 0 requires the use of AIX logical volume manager (LVM) mirroring.
- 3 The integrated SSDs are allowed to run in JBOD mode.
- 4 Nonvolatile write cache is supported only for RAID
disk arrays.
- 5 For more information about 520-byte sector format
virtual SCSI disk devices presented from the Virtual I/O Server (VIOS)
for the IBM i operating system, see
|