Server specifications provide detailed information for your server, including dimensions, electrical, power, temperature, environment, and service clearances.
Use the following specifications to plan for your server.
| Dimensions | Width | Depth | Height | EIA units1 | Weight |
|---|---|---|---|---|---|
| Metric | 429 mm | 524 mm | 218 mm | 5 | 25 kg |
| English | 16.9 in. | 20.6 in. | 8.6 in. | 55 lb |
| Dimensions | Width | Depth | Height | Weight |
|---|---|---|---|---|
| Metric | 216 mm 257 mm (including stabilizer foot) |
496 mm (without rear cover 525 mm (with rear cover1) |
469 mm | 25 kg |
| English | 8.5 in. 10.1 in. (including stabilizer foot) |
19.5 in. (without rear cover) 20.7 in. (with rear cover1) |
18.5 in. | 55 lb |
| 1An optional acoustical cover is available for the 7037-A50 server tower that will reduce LWAd and LpAm approximately 0.3 B and 3 dB, respectively. | ||||
| Dimensions | Width | Depth | Height | Weight |
|---|---|---|---|---|
| Metric | 216 mm 257 mm (including stabilizer foot) |
640 mm (with acoustical cover) |
469 mm | 25 kg |
| English | 8.5 in. 10.1 in. (including stabilizer foot) |
25.2 in. (with acoustical cover) |
18.5 in. | 55 lb |
| Dimensions | Width | Depth | Height | Weight |
|---|---|---|---|---|
| Metric | 625 mm | 655 mm | 485 mm | 30 kg |
| English | 24.6 in. | 25.8 in. | 19.1 in. | 67 lb |
| Dimensions | Width | Depth | Height | Weight |
|---|---|---|---|---|
| Metric | 625 mm | 655 mm | 599 mm | 30 kg |
| English | 24.6 in. | 25.8 in. | 23.5 in. | 67 lb |
| Electrical characteristics | Properties |
|---|---|
| kVA (maximum) | 0.474 |
| Rated voltage and frequency 1 | 100 - 127/200 - 240 V ac at 50/60 plus or minus 0.5 Hz |
| Thermal output (maximum) | 1536 BTU/hr |
| Maximum power consumption | 530 W (1-core 7037-A50 , 1-core 7047-185, and 2-core 7047-185) |
| 750 W (2-core 7037-A50 ) | |
| Power factor | 0.95 |
| Inrush current (maximum) | 90 A |
| Leakage current (maximum) | 1.6 mA |
| Phase | 1 |
| Branch circuit breaker | 20 A (maximum) |
| 1The power supplies automatically accept any voltage with the published, rated-voltage range. If dual power supplies are installed and operating, the power supplies draw approximately equal current from the utility (mains) and provide approximately equal current to the load. | |
| Environment | Temperature | |
|---|---|---|
| Recommended operating temperature 1 | 5 - 35 °C (41 - 95 °F) | |
| Nonoperating temperature | 5 - 45 °C (41 - 113 °F) | |
| Shipping temperature | -40 - 60 °C (-40 - 140 °F) | |
| Operating | Nonoperating | |
| Maximum dew point | 28 °C (82.4 - °F) | 29 °C (84.2 - °F) |
| Noncondensing humidity | 8 - 80% | 8 - 80% |
| Maximum altitude | 3048 m (10 000 ft) | 3048 m (10 000 ft) |
| 1Class 3 product as defined in ASHRAE Thermal Guidelines for Data Processing Environments. The allowable operating range is 5 - 35 °C (41 - 95 °F). See the Temperature and humidity design criteria topic for more information. | ||
| Product description | Declared A-weighted sound power level,LWAd (B) | Declared A-weighted sound pressure level,LpAm (dB) | ||
|---|---|---|---|---|
| Operating | Idling | Operating | Idling | |
| 7047-185 1-core workstation with two 10 000 rpm hard disk drives, 2843 graphics card and 2 GB of memory (workstations have acoustical front and rear covers) | 5.0 | 4.7 | 314 | 284 |
| 7047-185 2-core workstation with two 10 000 rpm hard disk drives, 2843 graphics card and 4GB of memory (workstations have acoustical front and rear covers) | 5.1 | 4.9 | 33 | 31 |
| 7037-A50 1-core server tower with three 10 000 rpm hard disk drives8 | 5.3 | 5.0 | 38 | 35 |
| 7037-A50 2-core server tower with three 10 000 rpm hard disk drives8 | 5.8 | 5.6 | 40 | 39 |
| 7037-A50 1-core rack-mounted server with three 10 000 rpm hard disk drives | 5.3 | 5.0 | 384 | 354 |
| 7037-A50 2-core server tower or rack-mounted server with three 10 000 rpm hard disk drives and 4 GB of memory | 5.7 | 5.6 | 42 | 41 |
This is an estimated value. When a tape drive is installed, using the acoustic cover feature will reduce the noise emissions when the tape drive is in use. All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296. For a description of noise emission values, see Acoustics. |
||||
| Clearances | Front | Back | Left or right | Top |
|---|---|---|---|---|
| Operating | 762 mm (30 in.) | 762 mm (30 in.) | ||
| Nonoperating | 762 mm (30 in.) | 762 mm (30 in.) | 762 mm (30 in.) | 762 mm (30 in.) |
Electromagnetic compatibility compliance: This server meets the following electromagnetic compatibility specifications: FCC (CFR 47, Part 15); VCCI; CISPR-22; 89/336/EEC; BSMI (A2/NZS 3548:1995); C-Tick; ICES/NMB-003; Korean EMI/EMC (MIC Notice 2000–94, Notice 2000–72); People's Republic of China Commodity Inspection Law.
Safety compliance: This server is designed and certified to meet the following safety standards: UL 60950; CAN/CSA C22.2 No. 60950–00; EN 60950; IEC 60950 including all National Differences