subscribe iconSubscribe to this information

Model 7037-A50 server and 7047-185 workstation specifications

Server specifications provide detailed information for your server, including dimensions, electrical, power, temperature, environment, and service clearances.

Use the following specifications to plan for your server.

Table 1. Rack-mounted 7037-A50 server
Dimensions Width Depth Height EIA units1 Weight
Metric 429 mm 524 mm 218 mm 5 25 kg
English 16.9 in. 20.6 in. 8.6 in. 55 lb
Table 2. Stand-alone 7037-A50 server
Dimensions Width Depth Height Weight
Metric

216 mm

257 mm (including stabilizer foot)

496 mm (without rear cover

525 mm (with rear cover1)

469 mm 25 kg
English

8.5 in.

10.1 in. (including stabilizer foot)

19.5 in. (without rear cover)

20.7 in. (with rear cover1)

18.5 in. 55 lb
1An optional acoustical cover is available for the 7037-A50 server tower that will reduce LWAd and LpAm approximately 0.3 B and 3 dB, respectively.
Table 3. Stand-alone 7047-185 workstation
Dimensions Width Depth Height Weight
Metric

216 mm

257 mm (including stabilizer foot)

640 mm (with acoustical cover)

469 mm 25 kg
English

8.5 in.

10.1 in. (including stabilizer foot)

25.2 in. (with acoustical cover)

18.5 in. 55 lb
Table 4. Shipping dimensions
Dimensions Width Depth Height Weight
Metric 625 mm 655 mm 485 mm 30 kg
English 24.6 in. 25.8 in. 19.1 in. 67 lb
Table 5. Shipping dimensions (China)
Dimensions Width Depth Height Weight
Metric 625 mm 655 mm 599 mm 30 kg
English 24.6 in. 25.8 in. 23.5 in. 67 lb
Table 6. Electrical
Electrical characteristics Properties
kVA (maximum) 0.474
Rated voltage and frequency 1 100 - 127/200 - 240 V ac at 50/60 plus or minus 0.5 Hz
Thermal output (maximum) 1536 BTU/hr
Maximum power consumption 530 W (1-core 7037-A50 , 1-core 7047-185, and 2-core 7047-185)
  750 W (2-core 7037-A50 )
Power factor 0.95
Inrush current (maximum) 90 A
Leakage current (maximum) 1.6 mA
Phase 1
Branch circuit breaker 20 A (maximum)
1The power supplies automatically accept any voltage with the published, rated-voltage range. If dual power supplies are installed and operating, the power supplies draw approximately equal current from the utility (mains) and provide approximately equal current to the load.
Table 7. Environment requirements
Environment Temperature
Recommended operating temperature 1 5 - 35 °C (41 - 95 °F)
Nonoperating temperature 5 - 45 °C (41 - 113 °F)
Shipping temperature -40 - 60 °C (-40 - 140 °F)
Operating Nonoperating
Maximum dew point 28 °C (82.4 - °F) 29 °C (84.2 - °F)
Noncondensing humidity 8 - 80% 8 - 80%
Maximum altitude 3048 m (10 000 ft) 3048 m (10 000 ft)
1Class 3 product as defined in ASHRAE Thermal Guidelines for Data Processing Environments. The allowable operating range is 5 - 35 °C (41 - 95 °F). See the Temperature and humidity design criteria topic for more information.
Table 8. Noise emissions
Product description Declared A-weighted sound power level,LWAd (B) Declared A-weighted sound pressure level,LpAm (dB)
  Operating Idling Operating Idling
7047-185 1-core workstation with two 10 000 rpm hard disk drives, 2843 graphics card and 2 GB of memory (workstations have acoustical front and rear covers) 5.0 4.7 314 284
7047-185 2-core workstation with two 10 000 rpm hard disk drives, 2843 graphics card and 4GB of memory (workstations have acoustical front and rear covers) 5.1 4.9 33 31
7037-A50 1-core server tower with three 10 000 rpm hard disk drives8 5.3 5.0 38 35
7037-A50 2-core server tower with three 10 000 rpm hard disk drives8 5.8 5.6 40 39
7037-A50 1-core rack-mounted server with three 10 000 rpm hard disk drives 5.3 5.0 384 354
7037-A50 2-core server tower or rack-mounted server with three 10 000 rpm hard disk drives and 4 GB of memory 5.7 5.6 42 41

This is an estimated value.

When a tape drive is installed, using the acoustic cover feature will reduce the noise emissions when the tape drive is in use.

All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296.

For a description of noise emission values, see Acoustics.

Table 9. Service clearances
Clearances Front Back Left or right Top
Operating 762 mm (30 in.) 762 mm (30 in.)  
Nonoperating 762 mm (30 in.) 762 mm (30 in.) 762 mm (30 in.) 762 mm (30 in.)

Electromagnetic compatibility compliance: This server meets the following electromagnetic compatibility specifications: FCC (CFR 47, Part 15); VCCI; CISPR-22; 89/336/EEC; BSMI (A2/NZS 3548:1995); C-Tick; ICES/NMB-003; Korean EMI/EMC (MIC Notice 2000–94, Notice 2000–72); People's Republic of China Commodity Inspection Law.

Safety compliance: This server is designed and certified to meet the following safety standards: UL 60950; CAN/CSA C22.2 No. 60950–00; EN 60950; IEC 60950 including all National Differences

Note: See 0551, 0553, 7014, and 0555 rack configurations for typical configurations when the 0551, 0553, 7014, and 0555 rack is populated with various server models.

Send feedback | Rate this page