Cabling for 9080-MHE, 9080-MME, 9119-MHE, or 9119-MME with two system nodes
Use this information to cable the 9080-MHE, 9080-MME, 9119-MHE, or 9119-MME with two system nodes in the configuration.
When you cable the 9080-MHE, 9080-MME, 9119-MHE, or 9119-MME with two system nodes in the configuration, you must connect the system nodes to each other, and you must connect each system node to the system control unit.
The following indexed diagrams help you understand port-to-port cabling between components in a configuration that has two system nodes. Use these diagrams with the tables that follow. To avoid connection issues, use the specified length of cable for each connection.
Figure 1. Symmetric multiprocessing (SMP) cabling for two
system nodes
Cable number | Cable type | From: (U-Loc) | To: (U-Loc) |
---|---|---|---|
1 | 1.5 m (4.9 ft) SMP cable | U2: P1-T3 | U4: P1-T1 |
2 | 1.25 m (4.1 ft) SMP cable | U2: P1-T1 | U4: P1-T3 |
3 | 1.25 m (4.1 ft) SMP cable | U2: P1-T2 | U4: P1-T2 |
4 | 1.25 m (4.1 ft) SMP cable | U2: P1-T5 | U4: P1-T5 |
5 | 1.25 m (4.1 ft) SMP cable | U2: P1-T6 | U4: P1-T4 |
6 | 1.5 m (4.9 ft) SMP cable | U2: P1-T4 | U4: P1-T6 |
Notes:
|
Figure 2. System node 1 to system control unit cabling
Cable number | Cable type | From: (U-Loc) | To: (U-Loc) |
---|---|---|---|
1 | 1.0 m (3.28 ft) global flexible service processor (GFSP) cable | U2: P1-C9-T2 | U3: P1-C7-T2 |
2 | 0.33 m (1.08 ft) universal power interconnect (UPIC) cable | U2: P1-C9-T1 | U3: P1-C2-T1 |
3 | Clock flex cable (D1L) | U2: P1-T7 | U3: P1-C8-T2 |
4 | Clock flex cable (D1R) | U2: P1-T8 | U3: P1-C9-T1 |
5 | 0.33 m (1.08 ft) UPIC cable | U2: P1-C10-T1 | U3: P1-C5-T1 |
6 | 1.0 m (3.28 ft) GFSP cable | U2: P1-C10-T2 | U3: P1-C10-T2 |
Note: U2 is system node 1
and U3 is system control unit.
|
Figure 3. System node 2 to system control unit cabling
Cable number | Cable type | From: (U-Loc) | To: (U-Loc) |
---|---|---|---|
1 | 1.0 m (3.28 ft) UPIC cable | U4: P1-C9-T1 | U3: P1-C1-T1 |
2 | 1.0 m (3.28 ft) GFSP cable | U4: P1-C9-T2 | U3: P1-C7-T5 |
3 | Clock flex cable (D2L) | U4: P1-T7 | U3: P1-C8-T3 |
4 | Clock flex cable (D2R) | U4: P1-T8 | U3: P1-C9-T4 |
5 | 1.0 m (3.28 ft) UPIC cable | U4: P1-C10-T1 | U3: P1-C6-T1 |
6 | 1.0 m (3.28 ft) GFSP cable | U4: P1-C10-T2 | U3: P1-C10-T5 |
Note: U4 is system node 2
and U3 is system control unit.
|