9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S locations
Use this information to help you map a location code to a position on the
unit.
The following diagrams show field-replaceable unit (FRU) layouts in the system. Use these diagrams with the following tables.
Rack views
Note: The following graphics represent location codes for 9009-41A, 9009-41G, 9009-42A,
9009-42G, 9223-42H, or 9223-42S.
The following table provides location codes for parts that comprise the server.
Failing item name | Physical location code | Identify LED | Failing item removal and replacement procedures |
---|---|---|---|
System unit | Un | ||
Fans | |||
Fan 1 | Un-A1 | Yes | See Fans. |
Fan 2 | Un-A2 | Yes | |
Fan 3 | Un-A3 | Yes | |
Fan 4 | Un-A4 | Yes | |
Fan 51 | Un-A5 | Yes | |
Fan 61 | Un-A6 | Yes | |
Power supplies | |||
Power supply 1 | Un-E1 | Yes | See Power supplies. |
Power supply 2 | Un-E2 | Yes | |
Power supply 3 | Un-E3 | Yes | |
Power supply 4 | Un-E4 | Yes | |
Backplanes | |||
System backplane | Un-P1 | Yes | See System backplane. |
Drive backplane | Un-P2 | Yes | See Drive backplanes. |
Ports | |||
USB 3.0 port 1 (front) | Un-P1-T3 | No | See Cables. |
USB 3.0 port 1 (rear) | Un-P1-T1 | No | |
USB 3.0 port 2 (rear) | Un-P1-T2 | No | |
USB 2.0 port 1 (rear) Note: This port is used only for firmware update and
uninterruptible power supply (UPS). This port is unavailable for host operating
systems.
|
Un-P1-C1-T3 | No | See Cables. |
USB 2.0 port 2 (rear) Note: This port is used only for firmware update and
uninterruptible power supply (UPS). This port is unavailable for host operating
systems.
|
Un-P1-C1-T4 | No | |
Serial port | Un-P1-C1-T5 | No | |
HMC port 1 | Un-P1-C1-T1 | No | |
HMC port 2 | Un-P1-C1-T2 | No | |
SAS cable port | Un-P1-C49-T1 | No | |
SAS cable port | Un-P1-C50-T1 | No | |
Adapters | |||
Service processor card | Un-P1-C1 | Yes | See Service processor card. |
Time-of-day battery | Un-P1-C1-E1 | Yes | See Time-of-day battery. |
PCIe4 x8 adapter1 | Un-P1-C2 | Yes | See Adapters. |
PCIe4 x16 adapter1 (supports CAPI and PCIe cable adapters) | Un-P1-C3 | Yes | |
PCIe4 x16 adapter1 (supports CAPI and PCIe cable adapters) | Un-P1-C4 | Yes | |
PCIe3 x8 adapter (9009-41A,
9009-42A, or 9223-42H) PCIe4 x8 adapter (9009-41G, 9009-42G, or 9223-42S) |
Un-P1-C5 | Yes | |
PCIe3 x8 adapter or SAS cable ports Un-P1-C49-T1 and
Un-P1-C50-T1 (9009-41A, 9009-42A, or 9223-42H) PCIe4 x16 adapter or SAS cable ports Un-P1-C49-T1 and Un-P1-C50-T1 (9009-41G, 9009-42G, or 9223-42S) |
Un-P1-C6 | Yes | |
PCIe3 x8 adapter (9009-41A, 9009-42A, or
9223-42H) PCIe4 x8 adapter (9009-41G, 9009-42G, or 9223-42S) |
Un-P1-C7 | Yes | |
PCIe4 x8 adapter (supports CAPI adapters) | Un-P1-C8 | Yes | See Adapters. |
PCIe4 x16 adapter (supports CAPI and PCIe cable adapters) | Un-P1-C9 | Yes | |
PCIe3 x8 adapter (9009-41A,
9009-42A, or 9223-42H) PCIe4 x8 adapter (9009-41G, 9009-42G, or 9223-42S) |
Un-P1-C10 | Yes | |
PCIe3 x8 adapter (9009-41A,
9009-42A, or 9223-42H) PCIe4 x8 adapter (9009-41G, 9009-42G, or 9223-42S) |
Un-P1-C11 | Yes | |
PCIe3 x8 adapter (9009-41A,
9009-42A, or 9223-42H) PCIe4 x16 adapter (9009-41G, 9009-42G, or 9223-42S) |
Un-P1-C12 | Yes | |
Vital product data card | Un-P1-C13 | Yes | See Vital product data card. |
Trusted platform module card | Un-P1-C14 | No | See Trusted platform module card. |
PCIe3 x8 SAS RAID internal adapter, PCIe3 x8 cache SAS RAID internal adapter, NVMe M.2 carrier card2, or NVMe U.2 pass-thru card3 | Un-P1-C49 | Yes | See one of the following procedures: . |
Backup power module card for the PCIe3 x8 cache SAS RAID internal adapter (see Figure 4) | Un-P1-C49-E1 | No | |
NVMe M.2 flash module2 (see Figure 6) | Un-P1-C49-C1 | No | See NVMe M.2 carrier card and flash modules. |
NVMe M.2 flash module2 (see Figure 6) | Un-P1-C49-C2 | No | |
PCIe3 x8 SAS RAID internal adapter, PCIe3 x8 cache SAS RAID internal adapter, NVMe M.2 carrier card2, or NVMe U.2 pass-thru card3 | Un-P1-C50 | Yes | See one of the following procedures: |
Backup power module card for the PCIe3 x8 cache SAS RAID internal adapter (see Figure 4) | Un-P1-C50-E1 | No | |
NVMe M.2 flash module2 (see Figure 6) | Un-P1-C50-C1 | No | See NVMe M.2 carrier card and flash modules. |
NVMe M.2 flash module2 (see Figure 6) | Un-P1-C50-C2 | No | |
Memory modules | |||
Memory module 1 | Un-P1-C15 | Yes | See Memory modules. |
Memory module 2 | Un-P1-C16 | Yes | |
Memory module 3 | Un-P1-C17 | Yes | |
Memory module 4 | Un-P1-C18 | Yes | |
Memory module 5 | Un-P1-C19 | Yes | |
Memory module 6 | Un-P1-C20 | Yes | |
Memory module 7 | Un-P1-C21 | Yes | |
Memory module 8 | Un-P1-C22 | Yes | |
Memory module 91 | Un-P1-C23 | Yes | |
Memory module 101 | Un-P1-C24 | Yes | |
Memory module 111 | Un-P1-C25 | Yes | |
Memory module 121 | Un-P1-C26 | Yes | |
Memory module 131 | Un-P1-C27 | Yes | |
Memory module 141 | Un-P1-C28 | Yes | |
Memory module 151 | Un-P1-C29 | Yes | |
Memory module 161 | Un-P1-C30 | Yes | |
Memory module 17 | Un-P1-C31 | Yes | |
Memory module 18 | Un-P1-C32 | Yes | |
Memory module 19 | Un-P1-C33 | Yes | |
Memory module 20 | Un-P1-C34 | Yes | |
Memory module 21 | Un-P1-C35 | Yes | |
Memory module 22 | Un-P1-C36 | Yes | |
Memory module 23 | Un-P1-C37 | Yes | |
Memory module 24 | Un-P1-C38 | Yes | |
Memory module 251 | Un-P1-C39 | Yes | |
Memory module 261 | Un-P1-C40 | Yes | |
Memory module 271 | Un-P1-C41 | Yes | |
Memory module 281 | Un-P1-C42 | Yes | |
Memory module 291 | Un-P1-C43 | Yes | |
Memory module 301 | Un-P1-C44 | Yes | |
Memory module 311 | Un-P1-C45 | Yes | |
Memory module 321 | Un-P1-C46 | Yes | |
Processor and processor regulator | |||
System processor module 1 | Un-P1-C47 | Yes | See System processor module. |
System processor module 21 | Un-P1-C48 | Yes | |
Device physical locations for systems with a 12-drive backplane (CCINs 2D34 and 6B64) | |||
Drive 1 | Un-P2-D1 | Yes | See Disk drives or solid-state drives. |
Drive 2 | Un-P2-D2 | Yes | |
Drive 3 | Un-P2-D3 | Yes | |
Drive 4 | Un-P2-D4 | Yes | |
Drive 5 | Un-P2-D5 | Yes | |
Drive 6 | Un-P2-D6 | Yes | |
Drive 7 | Un-P2-D7 | Yes | |
Drive 8 | Un-P2-D8 | Yes | |
Drive 9 | Un-P2-D9 | Yes | |
Drive 10 | Un-P2-D10 | Yes | |
Drive 11 | Un-P2-D11 | Yes | |
Drive 12 | Un-P2-D12 | Yes | |
RDX docking station (optional) | Un-P3 | No | See RDX docking stations. |
RDX removable disk drive (optional) | Un-P3-D1 | Yes | |
Device physical locations for systems with an 18-drive backplane (CCIN 2D35) | |||
Drive 1 | Un-P2-D1 | Yes | See Disk drives or solid-state drives. |
Drive 2 | Un-P2-D2 | Yes | |
Drive 3 | Un-P2-D3 | Yes | |
Drive 4 | Un-P2-D4 | Yes | |
Drive 5 | Un-P2-D5 | Yes | |
Drive 6 | Un-P2-D6 | Yes | |
Drive 7 | Un-P2-D7 | Yes | |
Drive 8 | Un-P2-D8 | Yes | |
Drive 9 | Un-P2-D9 | Yes | |
Drive 10 | Un-P2-D10 | Yes | |
Drive 11 | Un-P2-D11 | Yes | |
Drive 12 | Un-P2-D12 | Yes | |
Drive 13 | Un-P2-D13 | Yes | |
Drive 14 | Un-P2-D14 | Yes | |
Drive 15 | Un-P2-D15 | Yes | |
Drive 16 | Un-P2-D16 | Yes | |
Drive 17 | Un-P2-D17 | Yes | |
Drive 18 | Un-P2-D18 | Yes | |
Device physical locations for systems with an NVMe drive backplane (CCIN 2D3A)3 | |||
Drive 1 | Un-P2-D1 | Yes | See Disk drives or solid-state drives. |
Drive 2 | Un-P2-D2 | Yes | |
Drive 3 | Un-P2-D3 | Yes | |
Drive 4 | Un-P2-D4 | Yes | |
Drive 5 | Un-P2-D5 | Yes | |
Drive 6 | Un-P2-D6 | Yes | |
NVMe U.2 drive 1 | Un-P2-C1 | Yes | See NVMe U.2 drives. |
NVMe U.2 drive 2 | Un-P2-C2 | Yes | |
NVMe U.2 drive 3 | Un-P2-C3 | Yes | |
NVMe U.2 drive 4 | Un-P2-C4 | Yes | |
Control panel | |||
Control panel | Un-D1 | Yes | See Control panel and control panel display. |
Control panel display | Un-D2 | Yes | |
1 Not applicable for the 9009-41A or 9009-41G system. 2 Supported only on the 9009-41A, 9009-42A, or 9223-42H system. 3 Supported only on the 9009-41G, 9009-42G, or 9223-42S system. |