8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX locations

Use this information to find the location of a field-replaceable unit (FRU) in the system unit.

Note: The numbers for all of the FRU descriptions begin with 0 except for PCIe adapters, which begin with 1.

Rack views

The following diagrams show field-replaceable unit (FRU) layouts in the system. Use these diagrams with the following tables.

Rear view

Figure 1. Front view
Front view
Figure 2. Top view
Top view
Table 2. Top view locations
Index number FRU description FRU removal and replacement procedures
9 Disk drive and fan card
10 Time-of-day battery See Removing and replacing the time-of-day battery in the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX.
11 System backplane
12 CPU 0 See Removing and replacing a system processor module in the 8335-GTC, 8335-GTG, or 8335-GTH or Removing and replacing a system processor module in the 8335-GTW or 8335-GTX.
13 CPU 1
14 GPU 0 See Removing and replacing a graphics processing unit in the 8335-GTC, 8335-GTG, or 8335-GTH or Removing and replacing a graphics processing unit in the 8335-GTW or 8335-GTX.
15 GPU 1
16 GPU 2
Note: 8335-GTC, 8335-GTG, and 8335-GTH systems do not support this location.
17 GPU 3
18 GPU 4
19 GPU 5
Note: 8335-GTC, 8335-GTG, and 8335-GTH systems do not support this location.
20 Baseboard management controller (BMC) card See Removing and replacing the BMC card in the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX.
21 Trusted platform module
Note: 8335-GTC, 8335-GTG, and 8335-GTW systems do not support this location.
See Removing and replacing the trusted platform module in the 8335-GTH and 8335-GTX.
Rear view
Table 3. Rear view locations
Index number FRU description FRU removal and replacement procedures
22 PSU 0 See Removing and replacing a power supply in the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX.
23 PSU 1
24 PCIe adapter 1 See Removing and replacing PCIe adapters in the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX.
25 PCIe adapter 2
26 PCIe adapter 3
27 PCIe adapter 4
28 Baseboard management controller (BMC) card See Removing and replacing the BMC card in the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX.

Memory locations

The following diagram shows memory DIMMs and their corresponding field-replaceable unit (FRU) layouts in the system. Use this diagram with the following table.

Figure 3. Memory locations
Memory locations

The following table provides the memory locations.

Table 4. Memory locations
Index number FRU description FRU removal and replacement procedures
29 DIMM 0 See Removing and replacing memory in the 8335-GTC, 8335-GTG, or 8335-GTH or Removing and replacing memory in the 8335-GTW or 8335-GTX.
30 DIMM 1
31 DIMM 2
32 DIMM 3
33 DIMM 4
34 DIMM 5
35 DIMM 6
36 DIMM 7
37 DIMM 8
38 DIMM 9
39 DIMM 10
40 DIMM 11
41 DIMM 12
42 DIMM 13
43 DIMM 14
44 DIMM 15