Cabling for 9080-MHE and 9119-MHE with four system nodes

Use this information to cable the 9080-MHE and 9119-MHE with four system nodes in the configuration. (Model 9080-MME and 9119-MME cannot be cabled with four system nodes.)

When you cable the 9080-MHE and 9119-MHE with four system nodes in the configuration, you must connect the system nodes to each other, and you must connect each system node to the system control unit.

The following indexed diagrams help you understand port-to-port cabling between components in a configuration that has four system nodes. Use these diagrams with the tables that follow. To avoid connection issues, use the specified length of cable for each connection.

Figure 1. Symmetric multiprocessing (SMP) cabling for four system nodes (short cables)
Symmetric multiprocessing (SMP) cabling for four system nodes (short cables)
Table 1. Symmetric multiprocessing (SMP) cabling details for four system nodes (short cables)
Cable number Cable type From: (U-Loc) To: (U-Loc)
1 1.25 m (4.1 ft) SMP cable U1: P1-T3 U2: P1-T1
2 1.25 m (4.1 ft) SMP cable U4: P1-T1 U5: P1-T3
3 1.25 m (4.1 ft) SMP cable U2: P1-T2 U4: P1-T2
4 1.25 m (4.1 ft) SMP cable U2: P1-T5 U4: P1-T5
5 1.25 m (4.1 ft) SMP cable U1: P1-T4 U2: P1-T6
6 1.25 m (4.1 ft) SMP cable U4: P1-T6 U5: P1-T4
Notes:
  • U2 is system node 1, U4 is system node 2, U5 is system node 3, and U1 is system node 4.
  • Some 1.25 m SMP cables have labels at each end of the cable that indicate the length of the cable. The labels can be used during installation to distinguish the 1.25 m cable from the 1.5 m cable. The labels are not visible after the cable is installed.
Figure 2. Symmetric multiprocessing (SMP) cabling for four system nodes (long cables)
Symmetric multiprocessing (SMP) cabling for four system nodes (long cables)
Table 2. Symmetric multiprocessing (SMP) cabling details for four system nodes (long cables)
Cable number Cable type From: (U-Loc) To: (U-Loc)
1 1.5 m (4.9 ft) SMP cable U1: P1-T2 U5: P1-T2
2 1.5 m (4.9 ft) SMP cable U1: P1-T1 U4: P1-T3
3 1.5 m (4.9 ft) SMP cable U2: P1-T3 U5: P1-T1
4 1.5 m (4.9 ft) SMP cable U2: P1-T4 U5: P1-T6
5 1.5 m (4.9 ft) SMP cable U1: P1-T6 U4: P1-T4
6 1.5 m (4.9 ft) SMP cable U1: P1-T5 U5: P1-T5
Note: U2 is system node 1, U4 is system node 2, U5 is system node 3, and U1 is system node 4.
Figure 3. System node 1 to system control unit cabling
System node 1 to system control unit cabling
Table 3. System node 1 to system control unit cabling details
Cable number Cable type From: (U-Loc) To: (U-Loc)
1 1.0 m (3.28 ft) global flexible service processor (GFSP) cable U2: P1-C9-T2 U3: P1-C7-T2
2 0.33 m (1.08 ft) universal power interconnect (UPIC) cable U2: P1-C9-T1 U3: P1-C2-T1
3 Clock flex cable (D1L) U2: P1-T7 U3: P1-C8-T2
4 Clock flex cable (D1R) U2: P1-T8 U3: P1-C9-T1
5 0.33 m (1.08 ft) UPIC cable U2: P1-C10-T1 U3: P1-C5-T1
6 1.0 m (3.28 ft) GFSP cable U2: P1-C10-T2 U3: P1-C10-T2
Note: U2 is system node 1 and U3 is system control unit.
Figure 4. System node 2 to system control unit cabling
System node 2 to system control unit cabling
Table 4. System node 2 to system control unit cabling details
Cable number Cable type From: (U-Loc) To: (U-Loc)
1 1.0 m (3.28 ft) UPIC cable U4: P1-C9-T1 U3: P1-C1-T1
2 1.0 m (3.28 ft) GFSP cable U4: P1-C9-T2 U3: P1-C7-T5
3 Clock flex cable (D2L) U4: P1-T7 U3: P1-C8-T3
4 Clock flex cable (D2R) U4: P1-T8 U3: P1-C9-T4
5 1.0 m (3.28 ft) UPIC cable U4: P1-C10-T1 U3: P1-C6-T1
6 1.0 m (3.28 ft) GFSP cable U4: P1-C10-T2 U3: P1-C10-T5
Note: U4 is system node 2 and U3 is system control unit.
Figure 5. System node 3 to system control unit cabling
System node 3 to system control unit cabling
Table 5. System node 3 to system control unit cabling details
Cable number Cable type From: (U-Loc) To: (U-Loc)
1 1.0 m (3.28 ft) GFSP cable U5: P1-C9-T2 U3: P1-C7-T4
2 Clock flex cable (D3L) U5: P1-T7 U3: P1-C8-T4
3 Clock flex cable (D3R) U5: P1-T8 U3: P1-C9-T3
4 1.0 m (3.28 ft) GFSP cable U5: P1-C10-T2 U3: P1-C10-T4
Note: U5 is system node 3 and U3 is system control unit.
Figure 6. System node 4 to system control unit cabling
System node 4 to system control unit cabling
Table 6. System node 4 to system control unit cabling details
Cable number Cable type From: (U-Loc) To: (U-Loc)
1 1.0 m (3.28 ft) GFSP cable U1: P1-C9-T2 U3: P1-C7-T1
2 Clock flex cable (D4L) U1: P1-T7 U3: P1-C8-T1
3 Clock flex cable (D4R) U1: P1-T8 U3: P1-C9-T2
4 1.0 m (3.28 ft) GFSP cable U1: P1-C10-T2 U3: P1-C10-T1
Note: U1 is system node 4 and U3 is system control unit.